메뉴 건너뛰기




Volumn 58, Issue 7, 2001, Pages 868-884

Mass spectrometry for protein and peptide characterisation

Author keywords

Electrospray ionisation; Mass spectrometry; Matrix assisted laser desorption ionisation; Peptide; Protein; Quadrupole; Time of flight

Indexed keywords

ACCURACY; AMINO ACID SEQUENCE; ANALYTICAL EQUIPMENT; DESORPTION; DNA FINGERPRINTING; FLIGHT; GENE SEQUENCE; INSTRUMENTATION; LASER; MASS SPECTROMETRY; MEDICAL RESEARCH; PEPTIDE ANALYSIS; PROTEIN ANALYSIS; PROTEIN PROCESSING; PROTEIN STRUCTURE; REVIEW; SEQUENCE ANALYSIS; TANDEM MASS SPECTROMETRY; TECHNIQUE; TIME; VELOCITY;

EID: 0034947503     PISSN: 1420682X     EISSN: None     Source Type: Journal    
DOI: 10.1007/PL00000907     Document Type: Review
Times cited : (72)

References (159)
  • 3
    • 0014949207 scopus 로고
    • Cleavage of structural proteins during the assembly of the head of bacteriophage T4
    • (1970) Nature , vol.227 , pp. 680-685
    • Laemmli, U.K.1
  • 10
    • 0000239879 scopus 로고
    • The distribution of intensity along the positive ray parabolas of atoms and molecules of hydrogen and its possible explanation
    • (1919) Proc. Camb. Phil. Soc. , vol.19 , pp. 317-323
    • Aston, F.W.1
  • 25
    • 0003060357 scopus 로고
    • Angular aberrations in sector-shaped electromagnetic lenses for focusing beams of charged particles
    • (1953) Phys. Rev. , vol.91 , pp. 10-17
    • Johnson, E.G.1    Nier, A.O.2
  • 36
    • 0028575316 scopus 로고
    • Error-tolerant identification of peptides in sequence databases by peptide sequence tags
    • (1994) Anal. Chem. , vol.66 , pp. 4390-4399
    • Mann, M.1    Wilm, M.2
  • 52
    • 0001093176 scopus 로고
    • On the equilibrium of liquid conducting masses charged with electricity
    • (1882) Philos. Mag. , vol.14 , pp. 184-186
    • Rayleigh, L.1
  • 58
    • 0033926938 scopus 로고    scopus 로고
    • A brief overview of the present status of the mechanisms involved in electrospray mass spectrometry
    • (2000) J. Mass Spectrom. , vol.35 , pp. 804-817
    • Kebarle, J.1
  • 60
    • 0025866208 scopus 로고
    • Liquid chromatography-mass spectrometry with ionspray and electrospray interfaces in pharmaceutical and biomedical research
    • (1991) J. Chromatogr. , vol.554 , pp. 39-46
    • Bruins, A.P.1
  • 76
    • 0029331042 scopus 로고
    • Mass resolution improvement by incorporation of pulsed ion extraction/ionization linear time-of-flight mass spectrometry
    • (1995) Anal. Chem. , vol.67 , pp. 1998-2003
    • Brown, R.S.1    Lennon, J.J.2
  • 80
    • 10244264757 scopus 로고    scopus 로고
    • Exact mass measurements of polar organic molecules at low resolution using electrospray ionization and a quadrupole mass spectrometer
    • (1996) Anal. Chem. , vol.68 , pp. 3561-3569
    • Tyler, A.N.1    Clayton, E.2    Green, B.N.3
  • 101
    • 0000369624 scopus 로고
    • A method for the determination of the amino acid sequence in peptides
    • (1949) Arch. Biochem. , vol.22 , pp. 475-476
    • Edman, P.1
  • 133
    • 0029824087 scopus 로고    scopus 로고
    • Effect of alkyl substitution at the amide nitrogen on amide bond cleavage: Electrospray ionization/surface-induced dissociation fragmentation of substance P and two alkylated analogs
    • (1996) J. Mass Spectrom. , vol.31 , pp. 1141-1148
    • Nair, H.1    Somogyi, Á.2    Wysocki, V.H.3
  • 143
    • 0027461675 scopus 로고
    • Tandem mass spectrometry of very large molecules. 2. Dissociation of multiply charged proline-containing proteins from electrospray ionization
    • (1993) Anal. Chem. , vol.65 , pp. 425-438
    • Loo, J.A.1    Edmonds, C.G.2    Smith, R.D.3
  • 151
    • 0027529263 scopus 로고
    • Determination of amide hydrogen exchange by mass spectrometry: A new tool for protein structure elucidation
    • (1993) Protein Sci. , vol.2 , pp. 522-531
    • Zhang, Z.1    Smith, D.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.