Volumn 34, Issue 8, 2001, Pages 1005-1010
|
Experimental investigation of failure load and fracture patterns of C2 (axis)
|
Author keywords
Cervical spine; Experimental study; Hangman fracture; Odontoid fracture
|
Indexed keywords
DIAGNOSIS;
ENCAPSULATION;
FABRICATION;
FORCE MEASUREMENT;
FRACTURE;
STRUCTURAL LOADS;
POSTERIOR ELEMENTS;
BIOMECHANICS;
ADULT;
AGED;
ARTICLE;
CADAVER;
CERVICAL SPINE;
CONTROLLED STUDY;
ENCAPSULATION;
EXPERIMENT;
FORCE;
FRACTURE;
GEOMETRY;
HUMAN;
HUMAN TISSUE;
LOADING TEST;
MECHANICAL STRESS;
NECK INJURY;
ODONTOID PROCESS FRACTURE;
PRIORITY JOURNAL;
SPINE STABILIZATION;
VERTEBRA;
VERTEBRA BODY;
AGED;
AGED, 80 AND OVER;
BIOMECHANICS;
CERVICAL VERTEBRAE;
FEMALE;
HUMANS;
MALE;
MIDDLE AGED;
ODONTOID PROCESS;
SPINAL FRACTURES;
WEIGHT-BEARING;
|
EID: 0034934660
PISSN: 00219290
EISSN: None
Source Type: Journal
DOI: 10.1016/S0021-9290(01)00071-9 Document Type: Article |
Times cited : (17)
|