메뉴 건너뛰기




Volumn 8, Issue 8, 2001, Pages 651-657

Radiofrequency ablation for eradication of renal tumor in a rabbit model by using a cooled-tip electrode technique

Author keywords

Animal experiment; Magnetic resonance imaging; Minimally invasive surgery; Radiofrequency ablation; Renal neoplasms

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; CATHETER ABLATION; CONTROLLED STUDY; ELECTRODE; HISTOPATHOLOGY; KIDNEY TUMOR; LUNG METASTASIS; MINIMALLY INVASIVE SURGERY; NONHUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; RABBIT; RELAPSE; SURGICAL APPROACH; SURVIVAL RATE;

EID: 0034855254     PISSN: 10689265     EISSN: None     Source Type: Journal    
DOI: 10.1245/aso.2001.8.8.651     Document Type: Article
Times cited : (46)

References (32)
  • 8
    • 0032811777 scopus 로고    scopus 로고
    • Laparoscopic renal cryoablation: Acute and long-term clinical, radiographic, and pathologic effects in an animal model and application in a clinical trial
    • (1999) J Endourol , vol.13 , pp. 233-239
    • Bishoff, J.T.1    Chen, R.B.2    Lee, B.R.3
  • 12
    • 0033104373 scopus 로고    scopus 로고
    • Ablation of renal tumors in a rabbit model with interstitial saline-augmented radiofrequency energy: Preliminary report of a new technology
    • (1999) Urology , vol.53 , pp. 465-472
    • Polascik, T.J.1    Hamper, U.2    Lee, B.R.3
  • 15
    • 0033944535 scopus 로고    scopus 로고
    • Laparoscopic and percutaneous radiofrequency ablation of the kidney: Acute and chronic porcine study
    • (2000) Urology , vol.56 , pp. 197-200
    • Gill, I.S.1    Hsu, T.H.2    Fox, R.L.3
  • 16
    • 0030187101 scopus 로고    scopus 로고
    • A cooled needle electrode for radiofrequency tissue ablation: Thermodynamic aspects of improved performance compared with conventional needle design
    • (1996) Acad Radiol , vol.3 , pp. 556-563
    • Lorentzen, T.1
  • 17
    • 0031571146 scopus 로고    scopus 로고
    • Ex vivo experiment on radiofrequency liver ablation with saline infusion through a screw-tip cannulated electrode
    • (1997) J Surg Res , vol.71 , pp. 19-24
    • Miao, Y.1    Ni, Y.2    Mulier, S.3
  • 19
    • 0000097040 scopus 로고    scopus 로고
    • Large-volume tissue ablation with radio frequency by using a clustered, internally cooled electrode technique: Laboratory and clinical experience in liver metastases
    • (1998) Radiology , vol.209 , pp. 371-379
    • Goldberg, S.N.1    Solbiati, L.2    Hahn, P.F.3
  • 20
    • 0000374601 scopus 로고    scopus 로고
    • Optimization of radiofrequency ablation by using an "expandable-wet" electrode: Results of ex vivo experiment
    • abstract 8
    • (1999) Radiology , vol.213 , Issue.P , pp. 102
    • Miao, Y.1    Ni, Y.2    Yu, J.3    Marchal, G.4
  • 27
  • 28
  • 30
  • 31
    • 84951606693 scopus 로고
    • A transplantable rabbit carcinoma originating in a virus-induced papilloma and containing the virus in masked or altered form
    • (1940) J Exp Med , vol.71 , pp. 813-838
    • Kidd, J.G.1    Rous, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.