메뉴 건너뛰기




Volumn 95, Issue 2, 2001, Pages 149-156

Effective doses and organ doses in the MIRD-5 phantom exposed to monoenergetic 0.1 MeV to 200 MeV electrons in the LAT direction

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CONSTANTS AND COEFFICIENTS; CONTROLLED STUDY; DOSIMETRY; ELECTRON; ENERGY; GEOMETRY; HUMAN; MATHEMATICAL MODEL; ORGAN; RADIATION DOSE; RADIATION EXPOSURE; SIMULATION; STATISTICAL ANALYSIS; SYSTEM ANALYSIS;

EID: 0034834646     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a006535     Document Type: Article
Times cited : (5)

References (20)
  • 1
    • 0003733260 scopus 로고
    • 1990 Recommendations of the International Commission on Radiological Protection
    • International Commission on Radiation Protection. (Oxford: Pergamon Press) ICRP Publication 60
    • (1990)
  • 2
    • 0004159251 scopus 로고    scopus 로고
    • Conversion Coefficients for Use in Radiological Protection against External Radiation
    • International Commission on Radiation Protection. ICRP Publication 74 (Oxford: Pergamon Press)
    • (1996)
  • 3
    • 84965704645 scopus 로고
    • Recommendations of the International Commission on Radiological Protection
    • International Commission on Radiation Protection. Ann. ICRP 1(3); ICRP Publication 26 (Oxford: Pergamon Press)
    • (1977)
  • 4
    • 0004106225 scopus 로고
    • Determination of Dose Equivalent from External Radiation Sources
    • International Commission on Radiation Unit and Measurements. ICRU Report 43 (Bethesda, MD: ICRU Publications)
    • (1988)
  • 5
    • 0028273582 scopus 로고
    • Calculation of Absorbed Dose at 0.07, 3.0, and 10.0 mm Depths in a Slab Phantom for Monoenergetic Electrons
    • (1994) Radiat. Prot. Dosim. , vol.51 , Issue.2 , pp. 107-124
    • Hirayama, H.1
  • 7
    • 0028145115 scopus 로고
    • Determination of Electron Depth-Dose Curves for Water, ICRU Tissue, and PMMA and their Application to Radiation Protection Dosimetry
    • (1994) Radiat. Prot. Dosim. , vol.54 , Issue.2 , pp. 85-97
    • Grosswendt, B.1
  • 11
    • 0029970302 scopus 로고    scopus 로고
    • Organ and Effective Doses in the Male Phantom ADAM Exposed in AP Direction to Broad Unidirectional Beams of Monoenergetic Electrons
    • (1996) Health Phys. , vol.70 , Issue.4 , pp. 498-504
    • Schultz, F.W.1    Zoetelief, J.2
  • 12
    • 0031004062 scopus 로고    scopus 로고
    • Effective Dose per Unit Fluence Calculated for Adults and a 7 Year Old Girl in Broad Antero-posterior Beams of Monoenergetic Electrons of 0.1 to 10 MeV
    • (1997) Radiat. Prot. Dosim. , vol.69 , Issue.3 , pp. 179-186
    • Schultz, F.W.1    Zoetelief, J.2
  • 17
    • 0002490745 scopus 로고
    • Application of a General Purpose User's Version of the EGS4 Code System to a Phantom Skyshine Benchmarking Calculation
    • L1349A KEK Proc., No. 94-8
    • (1994) , pp. 59-68
    • Nojiri, I.1    Fukasaku, Y.2    Narita, O.3
  • 18
    • 0003562298 scopus 로고
    • Estimates of Specific Absorbed Fractions for Photon Sources Uniformly Distributed in Various Organs of a Heterogeneous Phantom
    • MIRD Pamphlet No. 5, Revised (New York: Society of Nuclear Medicine)
    • (1978)
    • Snyder, W.S.1    Ford, M.R.2    Warner, G.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.