메뉴 건너뛰기




Volumn 3, Issue , 2001, Pages 1441-1444

Guarded vector voltmeter for AC ratio standard calibration

Author keywords

Calibration; Voltage dividers

Indexed keywords

CALIBRATION; ELECTRIC POTENTIAL; NUMERICAL METHODS; PERSONAL COMPUTERS; VOLTAGE MEASUREMENT; VOLTMETERS;

EID: 0034822522     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (7)

References (16)
  • 4
    • 0024751570 scopus 로고
    • An improved straddling method with triaxial guards for the calibration of inductive voltage dividers at 1592 Hz
    • (1989) IEEE Trans. Instr. Meas. , vol.38 , Issue.3 , pp. 974-978
    • Hanke, R.1
  • 10
    • 0003614965 scopus 로고    scopus 로고
    • note
  • 11
    • 0003547272 scopus 로고    scopus 로고
    • note
  • 12
    • 0003537897 scopus 로고    scopus 로고
    • A3 is a Analog Devices OP-177 ultra-precision operational amplifier
  • 15
    • 0003609017 scopus 로고    scopus 로고
    • note
  • 16
    • 0003662370 scopus 로고    scopus 로고
    • note