Do age-based formulae predict the appropriate endotracheal tube sizes in Japanese children?

Author keywords

Age; Children; Endotracheal tube

Indexed keywords

AGE; ARTICLE; ARTIFICIAL MILK; BODY HEIGHT; BODY WEIGHT; CHILD; CONTROLLED STUDY; CORRELATION FUNCTION; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; HUMAN; INFANT; JAPAN; MAJOR CLINICAL STUDY; MEASUREMENT; PREDICTION; RETROSPECTIVE STUDY;

EID: 0034801995     PISSN: 09138668     EISSN: None     Source Type: Journal    
DOI: 10.1007/s005400170016     Document Type: Article
Times cited : (11)

References (14)
  • 2
    • 0014320672 scopus 로고
    • Length and cross-section growth patterns in the human trachea
    • (1968) Pediatrics , vol.42 , pp. 336-341
    • Butz, R.O.1
  • 9
    • 25744457852 scopus 로고    scopus 로고
    • Electronic anesthesia record keeping-part of a perioperative patient information system
    • Ikeda K, Dohi M, Kazama T (eds) State-of-the-art technology in anesthesia and intensive care. Elsevier, Amsterdam.
    • (1998) , pp. 271-274
    • Okamura, A.1    Sato, N.2    Hashimoto, T.3    Ishikawa, T.4    Kemmotsu, O.5
  • 10
    • 0019179146 scopus 로고
    • Comparative study on the various parameters in selecting the optimal size of endotracheal tube (in Japanese with English abstract)
    • (1980) Masui (Jpn J Anesthesiol) , vol.29 , pp. 1503-1508
    • Yasunaka, H.1