메뉴 건너뛰기




Volumn 65, Issue 1, 2000, Pages 273-276

Detection of ionic compounds in water with a new poly-carbon acid coated quartz crystal resonator

Author keywords

[No Author keywords available]

Indexed keywords

ABSORPTION; CRYSTAL RESONATORS; HEAVY METALS; INORGANIC ACIDS; ION EXCHANGE; ORGANIC ACIDS; ORGANIC COATINGS; POTABLE WATER; QUARTZ; TOXIC MATERIALS; WATER ANALYSIS; WATER QUALITY;

EID: 0034733328     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(99)00304-4     Document Type: Article
Times cited : (7)

References (8)
  • 1
    • 0032064599 scopus 로고    scopus 로고
    • Sensor system for the detection of organic pollutants in water by thickness shear mode resonators
    • Rösler S., Lucklum R., Borngräber R., Hartmann J., Hauptmann P. Sensor system for the detection of organic pollutants in water by thickness shear mode resonators. Sensors and Actuators B. 48:1998;416-425.
    • (1998) Sensors and Actuators B , vol.48 , pp. 416-425
    • Rösler, S.1    Lucklum, R.2    Borngräber, R.3    Hartmann, J.4    Hauptmann, P.5
  • 3
    • 0001433591 scopus 로고
    • Behaviour in solution of piezoelectric quartz crystals coated with poly(vinylpyridines)
    • Nomura T., Sakai M. Behaviour in solution of piezoelectric quartz crystals coated with poly(vinylpyridines). Anal. Chim. Acta. 183:1986;301-305.
    • (1986) Anal. Chim. Acta , vol.183 , pp. 301-305
    • Nomura, T.1    Sakai, M.2
  • 4
    • 37049079818 scopus 로고
    • Selective piezoelectric sensors using polymer reagents
    • Hunter T.C., Price G.J. Selective piezoelectric sensors using polymer reagents. Analyst. 120:1995;161-165.
    • (1995) Analyst , vol.120 , pp. 161-165
    • Hunter, T.C.1    Price, G.J.2
  • 5
    • 37049090846 scopus 로고
    • Application of crown ether coated piezoelectric crystal as a detector for the ion chromatography
    • Jane Y.S., Shil J.S. Application of crown ether coated piezoelectric crystal as a detector for the ion chromatography. Analyst. 120:1995;5-17.
    • (1995) Analyst , vol.120 , pp. 5-17
    • Jane, Y.S.1    Shil, J.S.2
  • 6
    • 0031176674 scopus 로고    scopus 로고
    • Detection of organic amines in liquid with chemically coated quartz crystal microbalance devices
    • Zhou X.C., Ng S.C., Chan H.S.O., Li S.F.Y. Detection of organic amines in liquid with chemically coated quartz crystal microbalance devices. Sensors and Actuators B. 42:1997;137-144.
    • (1997) Sensors and Actuators B , vol.42 , pp. 137-144
    • Zhou, X.C.1    Ng, S.C.2    Chan, H.S.O.3    Li, S.F.Y.4
  • 8
    • 0030232318 scopus 로고    scopus 로고
    • On-line-detection of organic pollutants in water by thickness shear mode resonators
    • Lucklum R., Rösler S., Hartmann J., Hauptmann P. On-line-detection of organic pollutants in water by thickness shear mode resonators. Sensors and Actuators B. 35-36:1996;103-111.
    • (1996) Sensors and Actuators B , vol.3536 , pp. 103-111
    • Lucklum, R.1    Rösler, S.2    Hartmann, J.3    Hauptmann, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.