메뉴 건너뛰기




Volumn 65, Issue 1, 2000, Pages 49-51

Hydrogen peroxide determination based on a glassy carbon electrode covered with polyion complex membrane containing peroxidase and mediator

Author keywords

[No Author keywords available]

Indexed keywords

ELECTROCHEMICAL ELECTRODES; ENZYME IMMOBILIZATION; HYDROGEN PEROXIDE; POLYSTYRENES; SENSITIVITY ANALYSIS;

EID: 0034733313     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(99)00435-9     Document Type: Article
Times cited : (50)

References (5)
  • 1
    • 0028810842 scopus 로고
    • Amperometric L-lactate-sensing electrode based on a polyion complex layer containing lactate oxidase. Application to serum and milk samples
    • Mizutani F., Yabuki S., Hirata Y. Amperometric L-lactate-sensing electrode based on a polyion complex layer containing lactate oxidase. Application to serum and milk samples. Anal. Chim. Acta. 314:1995;233.
    • (1995) Anal. Chim. Acta , vol.314 , pp. 233
    • Mizutani, F.1    Yabuki, S.2    Hirata, Y.3
  • 2
    • 0030271629 scopus 로고    scopus 로고
    • Flow injection analysis of L-lactic acid using an enzyme-polyion complex-coated electrode as the detector
    • Mizutani F., Yabuki S., Hirata Y. Flow injection analysis of L-lactic acid using an enzyme-polyion complex-coated electrode as the detector. Talanta. 43:1996;1815.
    • (1996) Talanta , vol.43 , pp. 1815
    • Mizutani, F.1    Yabuki, S.2    Hirata, Y.3
  • 3
    • 0000284508 scopus 로고    scopus 로고
    • Amperometric biosensors using poly-L-lysine/poly-(styrenesulfonate) membranes with immobilized enzymes
    • Mizutani F., Yabuki S., Hirata Y. Amperometric biosensors using poly-L-lysine/poly-(styrenesulfonate) membranes with immobilized enzymes. Denki Kagaku. 63:1996;1100.
    • (1996) Denki Kagaku , vol.63 , pp. 1100
    • Mizutani, F.1    Yabuki, S.2    Hirata, Y.3
  • 4
    • 0031475842 scopus 로고    scopus 로고
    • Amperometric alcohol-sensing electrode based on a polyion complex membrane containing alcohol oxidase
    • Mizutani F., Yabuki S., Iijima S. Amperometric alcohol-sensing electrode based on a polyion complex membrane containing alcohol oxidase. Anal. Sci. 13:1997;83.
    • (1997) Anal. Sci. , vol.13 , pp. 83
    • Mizutani, F.1    Yabuki, S.2    Iijima, S.3
  • 5
    • 0029256554 scopus 로고
    • Modifications to a carbon paste glucose-sensing enzyme electrode and a reduction in the electrochemical interference from L-ascorbate
    • Yabuki S., Mizutani F. Modifications to a carbon paste glucose-sensing enzyme electrode and a reduction in the electrochemical interference from L-ascorbate. Biosens. Bioelectronics. 10:1995;353.
    • (1995) Biosens. Bioelectronics , vol.10 , pp. 353
    • Yabuki, S.1    Mizutani, F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.