메뉴 건너뛰기




Volumn 101, Issue 16, 2000, Pages 1953-1959

A method for determining the reference effective flow areas for mechanical heart valve prostheses: In vitro validation studies

Author keywords

Blood flow; Echocardiography; Valves

Indexed keywords

ARTICLE; BIOMEDICAL ENGINEERING; BLOOD FLOW; HEART VALVE PROSTHESIS; LASER FLOWMETER; PRIORITY JOURNAL; PULSATILE FLOW;

EID: 0034712676     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.CIR.101.16.1953     Document Type: Article
Times cited : (14)

References (22)
  • 1
    • 0024466667 scopus 로고
    • Continuous wave Doppler echocardiographic measurement of prosthetic valve gradients: A simultaneous Doppler-catheter correlative study
    • Burstow DJ, Nishimura RA, Bailey KR, Reeder GS, Holmes DR Jr, Seward JB, Tajik AJ. Continuous wave Doppler echocardiographic measurement of prosthetic valve gradients: a simultaneous Doppler-catheter correlative study. Circulation. 1989;80:504-514.
    • (1989) Circulation , vol.80 , pp. 504-514
    • Burstow, D.J.1    Nishimura, R.A.2    Bailey, K.R.3    Reeder, G.S.4    Holmes D.R., Jr.5    Seward, J.B.6    Tajik, A.J.7
  • 2
    • 0032430124 scopus 로고    scopus 로고
    • Simultaneous Doppler and catheter transvalvular pressure gradients across St Jude bileaflet mitral valve prosthesis: In vivo study in a chronic animal model with pediatric valve sizes
    • Solowiejczyk DE, Yamada I, Cape EG, Manduley RA, Gersony WM, Jones M, Valdes-Cruz LM. Simultaneous Doppler and catheter transvalvular pressure gradients across St Jude bileaflet mitral valve prosthesis: in vivo study in a chronic animal model with pediatric valve sizes. J Am Soc Echocardiogr. 1998;11:1145-1154.
    • (1998) J Am Soc Echocardiogr , vol.11 , pp. 1145-1154
    • Solowiejczyk, D.E.1    Yamada, I.2    Cape, E.G.3    Manduley, R.A.4    Gersony, W.M.5    Jones, M.6    Valdes-Cruz, L.M.7
  • 3
    • 0024535070 scopus 로고
    • The gorlin formula validated against directly observed orifice area in porcine mitral bioprostheses
    • Chambers JB, Cochrane T, Black MM, Jackson G. The Gorlin formula validated against directly observed orifice area in porcine mitral bioprostheses. J Am Coll Cardiol. 1989;13:348-353.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 348-353
    • Chambers, J.B.1    Cochrane, T.2    Black, M.M.3    Jackson, G.4
  • 4
    • 0025997565 scopus 로고
    • Echocardiographic assessment of prosthetic valves
    • Nanda NC, Cooper JW, Mahan EF, Fan PH. Echocardiographic assessment of prosthetic valves. Circulation. 1991;84(suppl I):I-228-I-239.
    • (1991) Circulation , vol.84 , Issue.1 SUPPL.
    • Nanda, N.C.1    Cooper, J.W.2    Mahan, E.F.3    Fan, P.H.4
  • 5
    • 0029115783 scopus 로고
    • Doppler echocardiographic assessment with the continuity equation of St. Jude medical mechanical prostheses in the mitral valve position
    • Bitar JN, Lechin ME, Salazar G, Zoghbi WA. Doppler echocardiographic assessment with the continuity equation of St. Jude medical mechanical prostheses in the mitral valve position. Am J Cardiol. 1995;76:287-293.
    • (1995) Am J Cardiol , vol.76 , pp. 287-293
    • Bitar, J.N.1    Lechin, M.E.2    Salazar, G.3    Zoghbi, W.A.4
  • 6
    • 2542482858 scopus 로고
    • Baltimore, Md: Williams & Wilkins;
    • th ed. Baltimore, Md: Williams & Wilkins; 1993:678-681.
    • (1993) th Ed. , pp. 678-681
    • Feigenbaum, H.1
  • 7
    • 0032574652 scopus 로고    scopus 로고
    • Analysis of the effect of flow rate on the Doppler continuity equation for stenotic orifice area calculations: A numerical study
    • DeGroff C, Shandas R, Valdes-Cruz LM. Analysis of the effect of flow rate on the Doppler continuity equation for stenotic orifice area calculations: a numerical study. Circulation. 1998;97:1597-1605.
    • (1998) Circulation , vol.97 , pp. 1597-1605
    • DeGroff, C.1    Shandas, R.2    Valdes-Cruz, L.M.3
  • 8
    • 0031041551 scopus 로고    scopus 로고
    • Assessment of mitral regurgitation severity by Doppler color flow mapping of the vena contracta
    • Hall SA, Brickner E, Willet DL, Irani WN, Afridi I, Grayburn PA. Assessment of mitral regurgitation severity by Doppler color flow mapping of the vena contracta. Circulation. 1997;95:636-642.
    • (1997) Circulation , vol.95 , pp. 636-642
    • Hall, S.A.1    Brickner, E.2    Willet, D.L.3    Irani, W.N.4    Afridi, I.5    Grayburn, P.A.6
  • 9
    • 0031967532 scopus 로고    scopus 로고
    • Utility of three dimensional ultrasound Doppler flow reconstruction of the proximal jet to quantify effective orifice area: In vitro steady and pulsatile flow studies
    • Shandas R, DeGroff C, Kwon J, Trujillo N, Gill E, Valdes-Cruz LM. Utility of three dimensional ultrasound Doppler flow reconstruction of the proximal jet to quantify effective orifice area: in vitro steady and pulsatile flow studies. J Am Soc Echocardiogr. 1998;11:313-321.
    • (1998) J Am Soc Echocardiogr , vol.11 , pp. 313-321
    • Shandas, R.1    DeGroff, C.2    Kwon, J.3    Trujillo, N.4    Gill, E.5    Valdes-Cruz, L.M.6
  • 10
    • 0025792678 scopus 로고
    • Digital particle image velocimetry
    • Willert C, Gharib M. Digital particle image velocimetry. Experiments Fluids. 1991;10:181-187.
    • (1991) Experiments Fluids , vol.10 , pp. 181-187
    • Willert, C.1    Gharib, M.2
  • 13
    • 0039089111 scopus 로고
    • Value and limitations of proximal jet dimensions for the quantitation of valvular regurgitation
    • Baumgartner H, Schima H, Kuhn P. Value and limitations of proximal jet dimensions for the quantitation of valvular regurgitation. Circulation. 1993;87:841-848.
    • (1993) Circulation , vol.87 , pp. 841-848
    • Baumgartner, H.1    Schima, H.2    Kuhn, P.3
  • 16
  • 17
    • 0028959713 scopus 로고
    • Comparison of valvular resistance, stroke work loss, and Gorlin valve area for quantification of aortic stenosis: An in vitro study in a pulsatile aortic flow model
    • Voelker W, Reul H, Nienhaus G, Stelzer T, Schmitz B, Steegers A, Karsch KR. Comparison of valvular resistance, stroke work loss, and Gorlin valve area for quantification of aortic stenosis: an in vitro study in a pulsatile aortic flow model. Circulation. 1995;91:1196-1204.
    • (1995) Circulation , vol.91 , pp. 1196-1204
    • Voelker, W.1    Reul, H.2    Nienhaus, G.3    Stelzer, T.4    Schmitz, B.5    Steegers, A.6    Karsch, K.R.7
  • 18
    • 0343765766 scopus 로고    scopus 로고
    • Simultaneous determination of aortic valve area by the Gorlin formula and transesophageal echocardiography under different transvalvular flow conditions
    • Tardiff J-C, Rodrigues AG, Hardy J-F, Leclerc Y, Petitclerc R, Mongrain R, Mercier L-A. Simultaneous determination of aortic valve area by the Gorlin formula and transesophageal echocardiography under different transvalvular flow conditions. J Am Coll Cardiol. 1997;29:1296-1302.
    • (1997) J Am Coll Cardiol , vol.29 , pp. 1296-1302
    • Tardiff, J.-C.1    Rodrigues, A.G.2    Hardy, J.-F.3    Leclerc, Y.4    Petitclerc, R.5    Mongrain, R.6    Mercier, L.-A.7
  • 19
    • 0020970223 scopus 로고
    • Laser anemometry measurements of pulsatile flow past aortic valve prostheses
    • Chandran KB, Cabell GN, Khaligi B, Chen CJ. Laser anemometry measurements of pulsatile flow past aortic valve prostheses. J Biomech. 1983;16:865-873.
    • (1983) J Biomech , vol.16 , pp. 865-873
    • Chandran, K.B.1    Cabell, G.N.2    Khaligi, B.3    Chen, C.J.4
  • 20
    • 0028853909 scopus 로고
    • Pressure recovery in bileaflet heart valve prostheses: Localized high velocities and gradients in central and side orifices with implications for Doppler-catheter gradient relation in aortic and mitral position
    • Vandervoort PM, Greenberg NL, Pu M, Powell KA, Cosgrove DM, Thomas JD. Pressure recovery in bileaflet heart valve prostheses: localized high velocities and gradients in central and side orifices with implications for Doppler-catheter gradient relation in aortic and mitral position. Circulation. 1995;92:3464-3472.
    • (1995) Circulation , vol.92 , pp. 3464-3472
    • Vandervoort, P.M.1    Greenberg, N.L.2    Pu, M.3    Powell, K.A.4    Cosgrove, D.M.5    Thomas, J.D.6
  • 21
    • 0032558474 scopus 로고    scopus 로고
    • Application of color Doppler flow mapping to calculate orifice area of St. Jude mitral valve
    • Leung DY, Wong J, Rodriguez L, Pu M, Vandervoort PM, Thomas JD. Application of color Doppler flow mapping to calculate orifice area of St. Jude mitral valve. Circulation. 1998;98:1205-1211.
    • (1998) Circulation , vol.98 , pp. 1205-1211
    • Leung, D.Y.1    Wong, J.2    Rodriguez, L.3    Pu, M.4    Vandervoort, P.M.5    Thomas, J.D.6
  • 22
    • 0032815589 scopus 로고    scopus 로고
    • Real time three dimensional volumetric ultrasound imaging of the vena contracta for stenotic valves using echo contrast: In vitro pulsatile flow studies
    • Shandas R, Kwon J, Valdes-Cruz LM. Real time three dimensional volumetric ultrasound imaging of the vena contracta for stenotic valves using echo contrast: in vitro pulsatile flow studies. J Am Soc Echocardiogr. 1999;12:541-550.
    • (1999) J Am Soc Echocardiogr , vol.12 , pp. 541-550
    • Shandas, R.1    Kwon, J.2    Valdes-Cruz, L.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.