메뉴 건너뛰기




Volumn 53, Issue 4-5, 2000, Pages 651-656

System design for in vivo neutron activation analysis measurements of manganese in the human brain: Based on Monte Carlo modeling

Author keywords

Brain; In vivo; Manganese; Monte Carlo; Neutron activation analysis

Indexed keywords

BRAIN; COMPUTER SIMULATION; MANGANESE; MATHEMATICAL MODELS; MODERATORS; MONTE CARLO METHODS; NEUROLOGY; OPTICAL COLLIMATORS; OPTICAL MATERIALS; OPTIMIZATION; SYSTEMS ANALYSIS;

EID: 0034670262     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0969-8043(00)00199-8     Document Type: Article
Times cited : (19)

References (10)
  • 2
    • 0033000638 scopus 로고    scopus 로고
    • Nutrition versus toxicology in humans: Evaluation of potential biomarkers
    • Greger J.L. Nutrition versus toxicology in humans: evaluation of potential biomarkers. Neurotoxicology. 20:(23):1999;205-212.
    • (1999) Neurotoxicology , vol.20 , Issue.23 , pp. 205-212
    • Greger, J.L.1
  • 5
    • 0033040365 scopus 로고    scopus 로고
    • Total body-calcium measurements: Comparison of two delayed-gamma neutron activation facilities
    • Ma R., Ellis K.J., Yasumura S., Shypailo R.J., Pierson R.N. Jr. Total body-calcium measurements: comparison of two delayed-gamma neutron activation facilities. Phys. Med. Biol. 44:(6):1999;N113-118.
    • (1999) Phys. Med. Biol. , vol.44 , Issue.6 , pp. 113-118
    • Ma, R.1    Ellis, K.J.2    Yasumura, S.3    Shypailo, R.J.4    Pierson, R.N.5
  • 6
    • 0032079996 scopus 로고    scopus 로고
    • Improvement to the in vivo measurement of cadmium in the kidney by neutron activation analysis
    • McNeill F.E., Chettle D.R. Improvement to the in vivo measurement of cadmium in the kidney by neutron activation analysis. Radiat. Isot. 49:(56):1998;699-700.
    • (1998) Radiat. Isot. , vol.49 , Issue.56 , pp. 699-700
    • McNeill, F.E.1    Chettle, D.R.2
  • 7
    • 84992580275 scopus 로고
    • Nuclear Data Tables, National Academy of Science, Washington, DC
    • Nuclear Data Tables, 1960. Nuclear Data Tables, Part 3. National Academy of Science, Washington, DC.
    • (1960) Nuclear Data Tables , vol.3
  • 8
    • 0033002368 scopus 로고    scopus 로고
    • Manganese neurotoxicity: A review clinical features, imaging and pathology
    • Pal P.K., Sam A. III, Calne D.B. Manganese neurotoxicity: a review clinical features, imaging and pathology. Neurotoxicology. 20:(23):1999;227-238.
    • (1999) Neurotoxicology , vol.20 , Issue.23 , pp. 227-238
    • Pal, P.K.1    Sam A. III2    Calne, D.B.3
  • 9
    • 0014559581 scopus 로고
    • Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom
    • Snyder W.S., Fisher H.L. Jr, Ford M.R., Warner G.G. Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. J. Nucl. Med. Suppl. 3:1969;7-52.
    • (1969) J. Nucl. Med. , vol.3 , pp. 7-52
    • Snyder, W.S.1    Fisher, H.L.2    Ford, M.R.3    Warner, G.G.4
  • 10
    • 0026650638 scopus 로고
    • Accelerator-based epithermal neutron beam design for neutron capture therapy
    • Yanch J.C., Zhou X.-L. Accelerator-based epithermal neutron beam design for neutron capture therapy. Med. Phys. 19:(3):1992;709-721.
    • (1992) Med. Phys. , vol.19 , Issue.3 , pp. 709-721
    • Yanch, J.C.1    Zhou, X.-L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.