메뉴 건너뛰기




Volumn 52, Issue 5, 2000, Pages 1059-1064

Comparison of sample preparation and signal evaluation methods for EPR analysis of tooth enamel

Author keywords

Dose reconstruction; EPR; Tooth enamel

Indexed keywords

CONFERENCE PAPER; CONTROLLED STUDY; DOSIMETRY; ELECTRON SPIN RESONANCE; ENAMEL; EVALUATION; INTERMETHOD COMPARISON; IRRADIATION; MEASUREMENT; PRIORITY JOURNAL; RADIATION ABSORPTION; REPRODUCIBILITY; SAMPLE; SIGNAL PROCESSING; SPECTROMETER; TOOTH;

EID: 0034658536     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0969-8043(00)00050-6     Document Type: Conference Paper
Times cited : (37)

References (14)
  • 4
    • 0030294067 scopus 로고    scopus 로고
    • Tooth enamel as a detector material for retrospective EPR dosimetry
    • Egersdörfer S., Wieser A., Müller A. Tooth enamel as a detector material for retrospective EPR dosimetry. Appl. Radiat. Isot. 47:1996;1299-1303.
    • (1996) Appl. Radiat. Isot , vol.47 , pp. 1299-1303
    • Egersdörfer, S.1    Wieser, A.2    Müller, A.3
  • 5
    • 0031790258 scopus 로고    scopus 로고
    • Effectiveness of chemical etching for background EPR signal reduction in tooth enamel
    • Fattibene P., Aragno D., Onori S. Effectiveness of chemical etching for background EPR signal reduction in tooth enamel. Health Physics. 75:1999;500-505.
    • (1999) Health Physics , vol.75 , pp. 500-505
    • Fattibene, P.1    Aragno, D.2    Onori, S.3
  • 6
    • 0031122791 scopus 로고    scopus 로고
    • Improved accuracy of EPR dosimetry using a constant rotation goniometer
    • Haskell E.H., Hayes R.B., Kenner G.H. Improved accuracy of EPR dosimetry using a constant rotation goniometer. Radiat. Meas. 27:1997;325-329.
    • (1997) Radiat. Meas , vol.27 , pp. 325-329
    • Haskell, E.H.1    Hayes, R.B.2    Kenner, G.H.3
  • 11
    • 0028597949 scopus 로고
    • South Ural nuclear workers: Comparison of individual doses from retrospective EPR dosimetry and operational personal monitoring
    • Romanyukha A.A., Regulla D., Vasilenko E., Wieser A. South Ural nuclear workers: Comparison of individual doses from retrospective EPR dosimetry and operational personal monitoring. Appl. Radiat. Isot. 45:1994;1195-1199.
    • (1994) Appl. Radiat. Isot , vol.45 , pp. 1195-1199
    • Romanyukha, A.A.1    Regulla, D.2    Vasilenko, E.3    Wieser, A.4
  • 12
    • 85014071931 scopus 로고
    • Assessment of individual accumulated irradiation doses using EPR spectroscopy of tooth enamel
    • Skvortzov V.G., Ivannikov A.I., Eichoff U. Assessment of individual accumulated irradiation doses using EPR spectroscopy of tooth enamel. J. Mol. Struct. 347:1995;321-329.
    • (1995) J. Mol. Struct , vol.347 , pp. 321-329
    • Skvortzov, V.G.1    Ivannikov, A.I.2    Eichoff, U.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.