메뉴 건너뛰기




Volumn 130, Issue 15, 2000, Pages 545-550

Comparability of haematology profile between QBC® Autoread(TM) Plus System and an electronic cell counting instrument (Coulter Counter STKS);Vergleichbarkeit des blutstatus zwischen dem QBC®-Autoread(TM)-Plus- System und einem elektronischen zellzahlgerat (Coulter counter STKS)

Author keywords

Coulter Counter STKS; General practitioner's laboratory; Haematology profile; QBC Autoread(TM) Plus System

Indexed keywords

ACCURACY; ADOLESCENT; ADULT; AGED; ANALYTICAL EQUIPMENT; BLOOD CELL COUNT; CONFERENCE PAPER; CONTROLLED STUDY; COULTER COUNTER; EMERGENCY WARD; FEMALE; HEMATOCRIT; HEMATOLOGIC DISEASE; HEMOGLOBIN DETERMINATION; HUMAN; HUMAN CELL; LEUKOCYTE COUNT; LEUKOCYTE DIFFERENTIAL COUNT; MAJOR CLINICAL STUDY; MALE; THROMBOCYTE COUNT;

EID: 0034655337     PISSN: 00367672     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (2)

References (7)
  • 1
    • 0020659629 scopus 로고
    • Quantitative buffy coat analysis
    • Wardlaw SC, Levine RA. Quantitative buffy coat analysis. J Am Med Ass 1983;249:617-20.
    • (1983) J Am Med Ass , vol.249 , pp. 617-620
    • Wardlaw, S.C.1    Levine, R.A.2
  • 3
    • 0021045350 scopus 로고
    • A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry
    • Passing H, Bablok W. A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry. J Clin Chem Clin Biochem 1983;21:709-20.
    • (1983) J Clin Chem Clin Biochem , vol.21 , pp. 709-720
    • Passing, H.1    Bablok, W.2
  • 4
    • 84889138969 scopus 로고
    • Bericht über die Erfahrung mit QBC-II (zentrifugales Hämatologiesystem) in einem hämatologischen Speziallaboratorium
    • Muhm M, Hasel M, Martinelli-Holme E, Gabl F, Bettelheim P. Bericht über die Erfahrung mit QBC-II (zentrifugales Hämatologiesystem) in einem hämatologischen Speziallaboratorium. Ber Oest Ges Klin Chem 1990;13:18-21.
    • (1990) Ber Oest Ges Klin Chem , vol.13 , pp. 18-21
    • Muhm, M.1    Hasel, M.2    Martinelli-Holme, E.3    Gabl, F.4    Bettelheim, P.5
  • 5
    • 0024469278 scopus 로고
    • Hematological values from quantitative buffy coat analysis (QBC II) system: Evaluation in a hematological/oncological outpatient section
    • Riccardi A, Danova M, Quartero L, Besozzi M, Molinari E, Brugnatelli S, et al. Hematological values from quantitative buffy coat analysis (QBC II) system: evaluation in a hematological/oncological outpatient section. Haematologica 1989; 74:375-8.
    • (1989) Haematologica , vol.74 , pp. 375-378
    • Riccardi, A.1    Danova, M.2    Quartero, L.3    Besozzi, M.4    Molinari, E.5    Brugnatelli, S.6
  • 6
    • 84889126783 scopus 로고
    • Evaluation of the QBC autoread haematology system
    • England AP. Evaluation of the QBC autoread haematology system. Med Technol SA 1992;6:62-6.
    • (1992) Med Technol SA , vol.6 , pp. 62-66
    • England, A.P.1
  • 7
    • 0028772190 scopus 로고
    • Evaluation des QBC-Autoread-Systems zum hämatologischen Screening in einem Spitallaboratorium
    • Brabetz M, Streuli RA. Evaluation des QBC-Autoread-Systems zum hämatologischen Screening in einem Spitallaboratorium. Schweiz Rundsch Med Prax 1994;83:1034-8.
    • (1994) Schweiz Rundsch Med Prax , vol.83 , pp. 1034-1038
    • Brabetz, M.1    Streuli, R.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.