메뉴 건너뛰기




Volumn 2, Issue , 2000, Pages

Performance analysis of an improved 3D PET Monte Carlo simulation and scatter correction

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; COMPUTER WORKSTATIONS; IMAGE RECONSTRUCTION; MEDICAL IMAGING; MONTE CARLO METHODS;

EID: 0034594055     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (2)

References (18)
  • 1
    • 0027513305 scopus 로고
    • Correction and characterization of scattered events in three dimensional PET using scanners with retractable septa
    • S.R. Cherry, S.R. Meikle, and E.J. Hoffman, "Correction and Characterization of Scattered Events in Three Dimensional PET Using Scanners with Retractable Septa", Journal of Nuclear Medicine, vol. 34, pp. 671, 1993
    • (1993) Journal of Nuclear Medicine , vol.34 , pp. 671
    • Cherry, S.R.1    Meikle, S.R.2    Hoffman, E.J.3
  • 2
    • 0030067225 scopus 로고    scopus 로고
    • Model-based scatter correction for fully 3D PET
    • J.M. Ollinger and G.C. Johns, "Model-based Scatter Correction for Fully 3D PET," Physics in Medicine and Biology, vol. 41, pp. 153-176, 1996
    • (1996) Physics in Medicine and Biology , vol.41 , pp. 153-176
    • Ollinger, J.M.1    Johns, G.C.2
  • 4
    • 0026505930 scopus 로고
    • PETSIM: Monte Carlo program simulation of all sensitivity and resolution parameters of cylindrical positron imaging systems
    • C.J. Thompson, J.M. Cantu, and Y. Piccard, "PETSIM: Monte Carlo program simulation of all sensitivity and resolution parameters of cylindrical positron imaging systems," Physics in Medicine and Biology, vol. 37, pp. 731-749, 1992
    • (1992) Physics in Medicine and Biology , vol.37 , pp. 731-749
    • Thompson, C.J.1    Cantu, J.M.2    Piccard, Y.3
  • 6
    • 0344859870 scopus 로고    scopus 로고
    • An object-oriented Monte Carlo simulator for 3D positron tomographs
    • H. Zaidi, A Scheurer, and C. Moral, "An object-oriented Monte Carlo simulator for 3D positron tomographs," Computer Methods and Programs Biomedcine, vol. 58, pp. 133-145, 1999
    • (1999) Computer Methods and Programs Biomedcine , vol.58 , pp. 133-145
    • Zaidi, H.1    Scheurer, A.2    Moral, C.3
  • 7
    • 0003390329 scopus 로고    scopus 로고
    • The MC-PET project: Building an open-to-public database of Monte Carlo data sets for PET
    • Communication with I. Castioglioni, "The MC-PET Project: Building an open-to-public Database of Monte Carlo Data sets for PET," Society of Nuclear Medicine Annual Meeting Program, pp. 132, 2000
    • (2000) Society of Nuclear Medicine Annual Meeting Program , pp. 132
  • 8
    • 0032916211 scopus 로고    scopus 로고
    • Relevance of accurate Monte Carlo modeling in nuclear medical imaging
    • April
    • H. Zaidi, "Relevance of accurate Monte Carlo modeling in nuclear medical imaging," Medical Physics, vol. 26, pp. 574-608, April 1999
    • (1999) Medical Physics , vol.26 , pp. 574-608
    • Zaidi, H.1
  • 10
    • 0029357143 scopus 로고
    • "A Monte Carlo correction for the effect of Compton scattering in 3D PET brain imaging,"
    • August
    • C.S. Levin, M. Dahlbom, and E.J. Hoffman, "A Monte Carlo correction for the effect of Compton scattering in 3D PET brain imaging," IEEE Transactions on Nuclear Science, vol. 42, pp. 1181-85, August 1995
    • (1995) IEEE Transactions on Nuclear Science , vol.42 , pp. 1181-1185
    • Levin, C.S.1    Dahlbom, M.2    Hoffman, E.J.3
  • 11
    • 0013351050 scopus 로고    scopus 로고
    • Investigation of accelerated Monte Carlo techniques of PET simulation and 3D PET scatter correction
    • December
    • C.H. Holdsworth, "Investigation of Accelerated Monte Carlo Techniques of PET Simulation and 3D PET Scatter Correction," IEEE Transactions on Nuclear Science, December 2000
    • (2000) IEEE Transactions on Nuclear Science
    • Holdsworth, C.H.1
  • 12
    • 0031076959 scopus 로고    scopus 로고
    • Evaluation of simulation-based scatter correction of 3D cardiac imaging
    • February
    • C.C. Watson et al., "Evaluation of simulation-based scatter correction of 3D Cardiac Imaging," IEEE Transactions on Nuclear Science, vol. 44, pp. 90-97, February 1997
    • (1997) IEEE Transactions on Nuclear Science , vol.44 , pp. 90-97
    • Watson, C.C.1
  • 14
    • 0031376328 scopus 로고    scopus 로고
    • A technique for measuring the energy response of a PET tomograph using a compact scattering source
    • December
    • C.C. Watson, "A Technique for Measuring the Energy Response of a PET Tomograph Using a Compact Scattering Source," IEEE Transactions on Nuclear Science, vol. 44, pp. 2500-2508, December 1997
    • (1997) IEEE Transactions on Nuclear Science , vol.44 , pp. 2500-2508
    • Watson, C.C.1
  • 15
    • 0025418434 scopus 로고
    • Improving the efficiency of emission tomography simulations using variance reduction techniques
    • April
    • D.R. Haynor, R.L.Harrison, et al., "Improving the Efficiency of Emission Tomography Simulations Using Variance Reduction Techniques," IEEE Transactions on Nuclear Science, vol. 37, pp. 749-753, April 1990
    • (1990) IEEE Transactions on Nuclear Science , vol.37 , pp. 749-753
    • Haynor, D.R.1    Harrison, R.L.2
  • 16
    • 0031807850 scopus 로고    scopus 로고
    • Selection of task-dependent diffusion filters for the post-processing of SPECT images
    • F.J. Beekman, E.T.P. Slijpen, and W.J. Niessen, "Selection of Task-Dependent Diffusion Filters for the Post-Processing of SPECT Images," Physics in Medicine and Biology, vol. 43, pp. 1713-1730, 1998
    • (1998) Physics in Medicine and Biology , vol.43 , pp. 1713-1730
    • Beekman, F.J.1    Slijpen, E.T.P.2    Niessen, W.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.