메뉴 건너뛰기




Volumn 2, Issue , 2000, Pages

Virtual PMTs: Improving centroid positioning performance near the edges of a gamma camera detector

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; GAMMA RAYS; IMAGE QUALITY; IMAGE RECONSTRUCTION; OPTICAL RESOLVING POWER; PHOSPHORS; POSITRON EMISSION TOMOGRAPHY; RADIATION DETECTORS; X RAY CAMERAS;

EID: 0034593913     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (1)

References (5)
  • 1
    • 36849139664 scopus 로고
    • Scintillation camera
    • H.O. Anger, "Scintillation camera", Rev. Sci. Instrum., vol. 29, pp. 27-33, 1958.
    • (1958) Rev. Sci. Instrum. , vol.29 , pp. 27-33
    • Anger, H.O.1
  • 2
    • 0034204675 scopus 로고    scopus 로고
    • Implementation of ML based positioning algorithms for scintillation cameras
    • June
    • J. Joung, R.S. Miyaoka, S. Kohlmyer, T.K. Lewellen, "Implementation of ML based positioning algorithms for scintillation cameras", IEEE Trans. Nucl. Sci., vol. 47, no. 3, pp. 1104-1111, June 2000.
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , Issue.3 , pp. 1104-1111
    • Joung, J.1    Miyaoka, R.S.2    Kohlmyer, S.3    Lewellen, T.K.4
  • 3
    • 0001184093 scopus 로고    scopus 로고
    • A simple technique to increase the linearity and field-of-view in position sensitive photomultiplier tubes
    • June
    • R.L. Clancy, C.J. Thompson, J.L. Robar, and A.M. Bergman, "A simple technique to increase the linearity and field-of-view in position sensitive photomultiplier tubes", IEEE Trans. Nucl. Sci., vol. 44, no. 3, pp. 494-498, June 1997.
    • (1997) IEEE Trans. Nucl. Sci. , vol.44 , Issue.3 , pp. 494-498
    • Clancy, R.L.1    Thompson, C.J.2    Robar, J.L.3    Bergman, A.M.4
  • 4
    • 0013349233 scopus 로고    scopus 로고
    • The C-PET positron tomograph is manufactured by ADAC UGM, 3611 Market Street, Philadelphia, PA 19104
    • The C-PET positron tomograph is manufactured by ADAC UGM, 3611 Market Street, Philadelphia, PA 19104.
  • 5
    • 0001276637 scopus 로고
    • The effect of detector performance on high countrate PET imaging with a tomograph based on position-sensitive detectors
    • February
    • D.A. Mankoff, G. Muehllehner, and J.S. Karp, "The effect of detector performance on high countrate PET imaging with a tomograph based on position-sensitive detectors", IEEE Trans. Nucl. Sci., vol. 35, no. 1, pp. 592-597, February 1988.
    • (1988) IEEE Trans. Nucl. Sci. , vol.35 , Issue.1 , pp. 592-597
    • Mankoff, D.A.1    Muehllehner, G.2    Karp, J.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.