메뉴 건너뛰기




Volumn 2, Issue , 2000, Pages

Spatially-adaptive temporal smoothing for reconstruction of dynamic and gated image sequences

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; COMPUTER SIMULATION; IMAGE RECONSTRUCTION; SIGNAL DISTORTION;

EID: 0034593664     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (8)

References (18)
  • 2
    • 0021913818 scopus 로고
    • Use of nonstationary temporal Wiener filter in nuclear medicine
    • M.A. King and T. Miller, "Use of nonstationary temporal Wiener filter in nuclear medicine," Eur. J. Nucl. Med., vol. 10, pp. 458-461, 1985.
    • (1985) Eur. J. Nucl. Med. , vol.10 , pp. 458-461
    • King, M.A.1    Miller, T.2
  • 4
    • 0032587718 scopus 로고    scopus 로고
    • Fast spatio-temporal image reconstruction for dynamic PET
    • M. N. Wernick, E. J. Infusino, and M. Milosevic, "Fast spatio-temporal image reconstruction for dynamic PET," IEEE Trans. Med. Imag., vol. 18, pp. 185-195, 1999.
    • (1999) IEEE Trans. Med. Imag. , vol.18 , pp. 185-195
    • Wernick, M.N.1    Infusino, E.J.2    Milosevic, M.3
  • 7
    • 0031972212 scopus 로고    scopus 로고
    • Block-iterative techniques for fast 4D reconstruction using a priori motion models
    • D. S. Lalush and B. M. W. Tsui, "Block-iterative techniques for fast 4D reconstruction using a priori motion models," Phys. Med. Biol., vol. 43, pp. 875-886, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 875-886
    • Lalush, D.S.1    Tsui, B.M.W.2
  • 8
    • 0031283375 scopus 로고    scopus 로고
    • Image reconstruction for dynamic PET based on low-order approximation and restoration of the sinogram
    • C.-M. Kao, J.T. Yao, J. Mukherjee, and M. N. Wernick, "Image reconstruction for dynamic PET based on low-order approximation and restoration of the sinogram," IEEE Trans. Med. Imag, vol. 16, pp. 738-749, 1997.
    • (1997) IEEE Trans. Med. Imag , vol.16 , pp. 738-749
    • Kao, C.-M.1    Yao, J.T.2    Mukherjee, J.3    Wernick, M.N.4
  • 9
    • 0013390692 scopus 로고
    • Image processing of dynamic images with principal components analysis
    • J. T. Yap, J. D. Treffert, C.-T. Chen, and M. D. Cooper, "Image processing of dynamic images with principal components analysis," Radiol., vol. 185, pp. 177, 1992.
    • (1992) Radiol. , vol.185 , pp. 177
    • Yap, J.T.1    Treffert, J.D.2    Chen, C.-T.3    Cooper, M.D.4
  • 10
    • 0034178296 scopus 로고    scopus 로고
    • Improved image quality and computation reduction in 4D reconstruction of cardiac gated SPECT images
    • M. V. Narayanan, M. A. King, M. N. Wernick, C. L. Byrne, E. J. Soares, and P. H. Pretorius "Improved image quality and computation reduction in 4D reconstruction of cardiac gated SPECT images," IEEE Trans. Med. Imag., vol. 19, pp. 423-433, 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , pp. 423-433
    • Narayanan, M.V.1    King, M.A.2    Wernick, M.N.3    Byrne, C.L.4    Soares, E.J.5    Pretorius, P.H.6
  • 11
    • 0013399884 scopus 로고    scopus 로고
    • Fully adaptive temporal regression smoothing in gated cardiac SPECT image reconstruction
    • J. Peter, R. J. Jaszczak, B.F. Hutton, and H. M. Hudson, "Fully adaptive temporal regression smoothing in gated cardiac SPECT image reconstruction," submitted to IEEE Trans. Med. Imag.,
    • IEEE Trans. Med. Imag.
    • Peter, J.1    Jaszczak, R.J.2    Hutton, B.F.3    Hudson, H.M.4
  • 12
    • 0031385410 scopus 로고    scopus 로고
    • Detection of partial volume effected lesions in dynamic positron emission tomography images
    • X. Yu and P. Thanyasrisung, "Detection of partial volume effected lesions in dynamic positron emission tomography images," in Nucl. Sci. Symp. & Med. Imag. Conf., 1997.
    • Nucl. Sci. Symp. & Med. Imag. Conf., 1997
    • Yu, X.1    Thanyasrisung, P.2
  • 15
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • K. Lange and R. E. Carson, "EM reconstruction algorithms for emission and transmission tomography," J. Comput. Assist. Tomogr., vol. 8, no.2, pp. 306-316, 1984.
    • (1984) J. Comput. Assist. Tomogr. , vol.8 , Issue.2 , pp. 306-316
    • Lange, K.1    Carson, R.E.2
  • 16
    • 0030761578 scopus 로고    scopus 로고
    • Evaluation of right and left ventricular volume and ejection fraction using a mathematical cardiac torso phantom for gated blood pool SPECT
    • P.H. Pretorius, W. Xia, M.A. King, B.M.W. Tsui, T.S. Pan, and B.J. Villegas, "Evaluation of right and left ventricular volume and ejection fraction using a mathematical cardiac torso phantom for gated blood pool SPECT," J. of Nucl. Med., vol. 38, pp. 1528-1534, 1997.
    • (1997) J. of Nucl. Med. , vol.38 , pp. 1528-1534
    • Pretorius, P.H.1    Xia, W.2    King, M.A.3    Tsui, B.M.W.4    Pan, T.S.5    Villegas, B.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.