메뉴 건너뛰기




Volumn 3, Issue , 2000, Pages

Implementation of Monte Carlo coincident aperture functions in image generation of a high resolution animal positron tomograph

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; IMAGE ENHANCEMENT; IMAGE QUALITY; IMAGE RECONSTRUCTION; LUTETIUM COMPOUNDS; MONTE CARLO METHODS; RADIATION DETECTORS; TISSUE;

EID: 0034593615     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (12)
  • 4
    • 0032309695 scopus 로고    scopus 로고
    • Kalman sinogram restoration for fast and accurate PET image reconstruction
    • C.M. Kao, M.N. Wernic and C.-T. Chen: "Kalman sinogram restoration for fast and accurate PET image reconstruction", IEEE Trans. Nucl. Sci., vol. 45, no. 6, 1998, pp. 3022-3029.
    • (1998) IEEE Trans. Nucl. Sci. , vol.45 , Issue.6 , pp. 3022-3029
    • Kao, C.M.1    Wernic, M.N.2    Chen, C.-T.3
  • 5
    • 0026922961 scopus 로고
    • Effect of detector weighting functions on the point spread function of high-resolution PET tomographs: A simulation study
    • B. Karuta and R. Lecomte: "Effect of detector weighting functions on the point spread function of high-resolution PET tomographs: A simulation study", IEEE Trans. Med. Imag., vol. 11, no. 3, 1992, pp. 379-385.
    • (1992) IEEE Trans. Med. Imag. , vol.11 , Issue.3 , pp. 379-385
    • Karuta, B.1    Lecomte, R.2
  • 6
    • 0024610834 scopus 로고    scopus 로고
    • PET system calibrations and corrections for quantitative and spatially accurate images
    • E.J. Hoffman, T.M. Guerrero, G. Germano, W.M. Digby and M. Dahlbom: "PET system calibrations and corrections for quantitative and spatially accurate images", IEEE Trans. Nuc. Sci., vol. 36, no. 1, 1998, pp. 1108-1112.
    • (1998) IEEE Trans. Nuc. Sci. , vol.36 , Issue.1 , pp. 1108-1112
    • Hoffman, E.J.1    Guerrero, T.M.2    Germano, G.3    Digby, W.M.4    Dahlbom, M.5
  • 7
    • 0028447935 scopus 로고
    • Detector response restoration in image reconstruction of high resolution positron emission tomography
    • Z. Liang: "Detector response restoration in image reconstruction of high resolution positron emission tomography", IEEE Trans. Med. Imag., vol. 13, no. 2, 1994, pp. 314-3321.
    • (1994) IEEE Trans. Med. Imag. , vol.13 , Issue.2 , pp. 314-3321
    • Liang, Z.1
  • 8
    • 0034205094 scopus 로고    scopus 로고
    • Detector response models for statistical iterative image reconstruction in high resolution PET
    • V. Selivanov, Y. Pichard, J. Cardorette, S. Rodrigue and R. Lecomte: "Detector response models for statistical iterative image reconstruction in high resolution PET", IEEE Trans. Nucl. Sci., vol. 47, no. 3, 2000, pp. 1168-1175.
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , Issue.3 , pp. 1168-1175
    • Selivanov, V.1    Pichard, Y.2    Cardorette, J.3    Rodrigue, S.4    Lecomte, R.5
  • 9
    • 0026220223 scopus 로고
    • Study of the resolution performance of an array of discrete detectors with independent readouts for positron emission tomography
    • R. Lecomte, C. Martel, J. Cadorette: "Study of the resolution performance of an array of discrete detectors with independent readouts for positron emission tomography", IEEE Trans. Med. Imaging, vol. 10, no. 3, 1991, pp. 347-357.
    • (1991) IEEE Trans. Med. Imaging , vol.10 , Issue.3 , pp. 347-357
    • Lecomte, R.1    Martel, C.2    Cadorette, J.3
  • 10
    • 0033314172 scopus 로고    scopus 로고
    • Attenuation and scatter correction of list-mode driven iterative and analytic image reconstruction algorithms for rotating 3D PET systems
    • A.J. Reader, R.J. Ott and M.A. Flower: "Attenuation and scatter correction of list-mode driven iterative and analytic image reconstruction algorithms for rotating 3D PET systems", IEEE Trans. Nucl. Sci., vol. 46, no. 6, 1999, pp. 2218-2226.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , Issue.6 , pp. 2218-2226
    • Reader, A.J.1    Ott, R.J.2    Flower, M.A.3
  • 11
    • 0028446166 scopus 로고
    • Penalized weighted least-squares image reconstruction for positron emission tomography
    • J.A. Fessler: "Penalized weighted least-squares image reconstruction for positron emission tomography", IEEE Trans. Med. Imag., vol. 13, no. 2, 1994, pp. 290-300.
    • (1994) IEEE Trans. Med. Imag. , vol.13 , Issue.2 , pp. 290-300
    • Fessler, J.A.1
  • 12
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • H.M. Hudson and R.S. Larkin: "Accelerated image reconstruction using ordered subsets of projection data", IEE Trans. Med. Imag., vol. 13, 1994, pp. 601-609.
    • (1994) IEE Trans. Med. Imag. , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.