메뉴 건너뛰기




Volumn 22, Issue 6, 2000, Pages 407-415

Theoretical analysis of the measurement of polarization resistance in reinforced concrete

Author keywords

[No Author keywords available]

Indexed keywords

ELECTROCHEMICAL CORROSION; GALVANIZING; MATHEMATICAL MODELS; POLARIZATION; SENSORS;

EID: 0034545157     PISSN: 09589465     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0958-9465(00)00040-8     Document Type: Article
Times cited : (101)

References (33)
  • 1
    • 84975434808 scopus 로고
    • Electrochemical polarization, I. A theoretical analysis of the shape of polarizationi curves
    • Stern M., Geary A.L. Electrochemical polarization, I. A theoretical analysis of the shape of polarizationi curves. J Electrochem Soc. 104:1957;56-63.
    • (1957) J Electrochem Soc , vol.104 , pp. 56-63
    • Stern, M.1    Geary, A.L.2
  • 2
    • 0000305710 scopus 로고
    • The polarisation resistance technique for measuring corrosion currents
    • In: Fontana MG, Staehle RN. editors
    • Manfield F. The polarisation resistance technique for measuring corrosion currents. In: Fontana MG, Staehle RN. editors. Advances in corrosion science and technology, vol. 6; 1970. p. 163-262.
    • (1970) Advances in Corrosion Science and Technology , vol.6 , pp. 163-262
    • Manfield, F.1
  • 3
    • 0028166850 scopus 로고
    • Programmable linear polarisation meter for determination of corrosion rate of reinforcement in concrete structures
    • Gowers K.R., Millard S.G., Gill J.S.et al. Programmable linear polarisation meter for determination of corrosion rate of reinforcement in concrete structures. British Corros J. 29:1994;25-32.
    • (1994) British Corros J , vol.29 , pp. 25-32
    • Gowers, K.R.1    Millard, S.G.2    Gill, J.S.3
  • 8
    • 0342674750 scopus 로고
    • Crawford GC. Inclusion of rebar corrosion rate measurements in condition surveys of concrete bridge decks
    • Clemena G.G., Jackson D.R. Crawford GC. Inclusion of rebar corrosion rate measurements in condition surveys of concrete bridge decks. Transport Res Rec. 1347:1995;37-45.
    • (1995) Transport Res Rec , vol.1347 , pp. 37-45
    • Clemena, G.G.1    Jackson, D.R.2
  • 9
    • 0027625468 scopus 로고
    • Electrochemical measurements on bridges for evaluation of reinforcement corrosion rates
    • Flis J., Sabol S., Pickering H.W., Sehgal A., Osseo-Asare K., Cady P.D. Electrochemical measurements on bridges for evaluation of reinforcement corrosion rates. Corrosion. 49(7):1993;601-613.
    • (1993) Corrosion , vol.49 , Issue.7 , pp. 601-613
    • Flis, J.1    Sabol, S.2    Pickering, H.W.3    Sehgal, A.4    Osseo-Asare, K.5    Cady, P.D.6
  • 11
    • 0029254257 scopus 로고
    • Suitability of assessment methods for identifying active and passive zones in reinforced concrete
    • González J.A., Benito M., Feliu S., Rodríguez P., Andrade C. Suitability of assessment methods for identifying active and passive zones in reinforced concrete. Corrosion. 51(2):1995;145-152.
    • (1995) Corrosion , vol.51 , Issue.2 , pp. 145-152
    • González, J.A.1    Benito, M.2    Feliu, S.3    Rodríguez, P.4    Andrade, C.5
  • 12
    • 0342674749 scopus 로고    scopus 로고
    • Effect of microcracks on durability of ultra high strength concrete
    • C.L. Page, P.B. Bamforth, & J.W. Figg. Cambridge: The Royal Society of Chemistry
    • Aarup B., Klinghoffer O. Effect of microcracks on durability of ultra high strength concrete. Page C.L., Bamforth P.B., Figg J.W. Corrosion of reinforcement in concrete construction. 1996;611-619 The Royal Society of Chemistry, Cambridge.
    • (1996) Corrosion of Reinforcement in Concrete Construction , pp. 611-619
    • Aarup, B.1    Klinghoffer, O.2
  • 13
    • 0024082455 scopus 로고
    • Relation between resistivity and corrosion rate of reinforcements in carbonated mortar made with several cement types
    • Alonso C., Andrade A., González J.A. Relation between resistivity and corrosion rate of reinforcements in carbonated mortar made with several cement types. Cement Concrete Res. 8:1988;687-698.
    • (1988) Cement Concrete Res , vol.8 , pp. 687-698
    • Alonso, C.1    Andrade, A.2    González, J.A.3
  • 14
    • 0030216918 scopus 로고    scopus 로고
    • Corrosion resistance of stainless steel in chloride contaminated concrete
    • Gu P., Elliott S., Beaudoin J.J., Arsenault B. Corrosion resistance of stainless steel in chloride contaminated concrete. Cement Concrete Res. 26(8):1996;1151-1156.
    • (1996) Cement Concrete Res , vol.26 , Issue.8 , pp. 1151-1156
    • Gu, P.1    Elliott, S.2    Beaudoin, J.J.3    Arsenault, B.4
  • 15
    • 0019896186 scopus 로고
    • Effect of carbonation, chlorides and relative ambient humidity on the corrosion of galvanized rebars embedded in concrete
    • González J.A., Andrade C. Effect of carbonation, chlorides and relative ambient humidity on the corrosion of galvanized rebars embedded in concrete. British Corros J. 17:1982;21-28.
    • (1982) British Corros J , vol.17 , pp. 21-28
    • González, J.A.1    Andrade, C.2
  • 16
    • 0008532730 scopus 로고
    • Corrosion rate measurement and life prediction for reinforced concrete structures
    • University of Edinburgh: Engineering Technical Press
    • Broomfield JP, Rodríguez J, Ortega LM, Garcia AM. Corrosion rate measurement and life prediction for reinforced concrete structures. In: Proceedings of Structural Faults and Repair-93, vol. 2. University of Edinburgh: Engineering Technical Press; 1993. p. 155.
    • (1993) In: Proceedings of Structural Faults and Repair-93 , vol.2 , pp. 155
    • Broomfield, J.P.1    Rodríguez, J.2    Ortega, L.M.3    Garcia, A.M.4
  • 17
    • 85055186093 scopus 로고
    • Corrosion rate measurements in reinforced concrete structures by a linear polarisation device
    • In: Weyers RE. editor SP 151-9, (American Concrete Institute, Special Publication)
    • Broomfield JP, Rodríguez J, Ortega LM, Garcia AM. Corrosion rate measurements in reinforced concrete structures by a linear polarisation device. In: Weyers RE. editor. Symposium on Corrosion of Steel in Concrete. SP 151-9, (American Concrete Institute, Special Publication); 1994. p. 163.
    • (1994) Symposium on Corrosion of Steel in Concrete , pp. 163
    • Broomfield, J.P.1    Rodríguez, J.2    Ortega, L.M.3    Garcia, A.M.4
  • 18
    • 0024777283 scopus 로고
    • Measuring the rate of corrosion of steel in field concrete structures
    • Transportation Research Board, National Research Council, Washington, DC
    • Clear KC. Measuring the rate of corrosion of steel in field concrete structures. Transportation Research Record 1211, Transportation Research Board, National Research Council, Washington, DC; 1989.
    • (1989) Transportation Research Record , vol.1211
    • Clear, K.C.1
  • 20
    • 84894037252 scopus 로고    scopus 로고
    • Corrosion of steel in concrete: Causes, detection and prediction, A state-of-the-art review
    • ARRB Transport Research Ltd
    • Song G, Shayan A. Corrosion of steel in concrete: causes, detection and prediction, A state-of-the-art review, Review Report 4. ARRB Transport Research Ltd; 1998.
    • (1998) Review Report , vol.4
    • Song, G.1    Shayan, A.2
  • 21
    • 85031546164 scopus 로고    scopus 로고
    • Publication No. FHWA-RD-96-178. Research and Development, Turner-Fairbank Highway Research Center, 6300 Georgetown Pike, Mclean, Virginia
    • Bertocci U. Impedance spectroscopy for the evaluation of corrosion inhibitors in highway deicers, Publication No. FHWA-RD-96-178. Research and Development, Turner-Fairbank Highway Research Center, 6300 Georgetown Pike, Mclean, Virginia; 1997.
    • (1997) Impedance Spectroscopy for the Evaluation of Corrosion Inhibitors in Highway Deicers
    • Bertocci, U.1
  • 22
    • 0342674722 scopus 로고
    • An electrochemical method for detecting ongoing corrosion of steel in a concrete structure with CP applied
    • National Research Council, Washington, DC
    • Thompson NG, Lawson KM. An electrochemical method for detecting ongoing corrosion of steel in a concrete structure with CP applied, Strategic Highway Research Program, National Research Council, Washington, DC; 1991.
    • (1991) Strategic Highway Research Program
    • Thompson, N.G.1    Lawson, K.M.2
  • 23
    • 0026816850 scopus 로고
    • The effect of macrocells between active and passive areas of steel reinforcements
    • Andrade C., Maribona I.R., Feliu S., González J.A., Feliu S. Jr. The effect of macrocells between active and passive areas of steel reinforcements. Corr Sci. 33(2):1992;237-249.
    • (1992) Corr Sci , vol.33 , Issue.2 , pp. 237-249
    • Andrade, C.1    Maribona, I.R.2    Feliu, S.3    González, J.A.4    Feliu S., Jr.5
  • 25
    • 85031550238 scopus 로고    scopus 로고
    • Advances in the on-site electrochemical measurement of reinforcement corrosion and their use for predicting residual life
    • Andrade C., Alonso C., Feliú S., González J.A. Advances in the on-site electrochemical measurement of reinforcement corrosion and their use for predicting residual life. Corr Mater. 22(4):1997;8-12.
    • (1997) Corr Mater , vol.22 , Issue.4 , pp. 8-12
    • Andrade, C.1    Alonso, C.2    Feliú, S.3    González, J.A.4
  • 26
    • 0025120131 scopus 로고
    • Possibilities of the guard ring for electrical signal confinement in the polarization measurements of reinforcements
    • Feliu S., Escudero M.L., Feliu S. Jr., González J.A. Possibilities of the guard ring for electrical signal confinement in the polarization measurements of reinforcements. Corrosion. 46:1990;1015-1020.
    • (1990) Corrosion , vol.46 , pp. 1015-1020
    • Feliu, S.1    Escudero, M.L.2    Feliu S., Jr.3    González, J.A.4
  • 27
    • 0025489042 scopus 로고
    • Confinement of the electrical signal for in situ measurement of polarization resistance in reinforced concrete
    • Feliu S., González J.A., Feliu S. Jr., Andrade C. Confinement of the electrical signal for in situ measurement of polarization resistance in reinforced concrete. ACI Mater J. 87(5):1990;457-460.
    • (1990) ACI Mater J , vol.87 , Issue.5 , pp. 457-460
    • Feliu, S.1    González, J.A.2    Feliu S., Jr.3    Andrade, C.4
  • 28
    • 0343544885 scopus 로고
    • Errors in the on-site measurements of rebar corrosion rates arising from signal unconfinement
    • In: Cady PD. editor (Minnesota) ACI SP-151
    • Feliu S, González JA, Andrade C., Errors in the on-site measurements of rebar corrosion rates arising from signal unconfinement. In: Cady PD. editor. Symposium, Minneapolis, (Minnesota) 1993; ACI SP-151: p. 183.
    • (1993) Symposium, Minneapolis , pp. 183
    • Feliu, S.1    González, J.A.2    Andrade, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.