-
2
-
-
0006699548
-
-
Request for Proposal No. NHLBI-HV-92-28 Bethesda, MD: National Heart, Lung, and Blood Institute
-
(1992)
-
-
-
3
-
-
0027377874
-
In vivo long-term evaluation of the Utah electrohydraulic total artificial heart
-
(1993)
ASAIO J
, vol.39
-
-
Tatsumi, E.1
Khanwilkar, P.S.2
Rowles, J.R.3
Chiang, B.Y.4
Burns, G.L.5
Long, J.W.6
Hansen, A.C.7
Holfert, J.W.8
Bearnson, G.B.9
Crump, K.R.10
Krivoy, S.R.11
Smith, N.L.12
Olsen, D.B.13
-
4
-
-
0027454370
-
In vivo testing of a completely implantable total artificial heart system
-
(1993)
ASAIO J
, vol.39
-
-
Snyder, A.J.1
Rosenberg, G.2
Weiss, W.J.3
Ford, S.K.4
Nazarian, R.A.5
Hicks, D.L.6
Marlotte, J.A.7
Kawaguchi, O.8
Prophet, G.A.9
Sapirstein, J.S.10
Schwartz, M.11
Pierce, W.S.12
-
5
-
-
0000677483
-
Design and trial fabrication of a total artificial heart for Japanese
-
(1988)
Jpn J Artif Organs
, vol.17
, pp. 835-838
-
-
Taenaka, Y.1
Takano, H.2
Takatani, S.3
Yagura, A.4
Kinoshita, M.5
Noda, H.6
Tatsumi, E.7
Akutsu, T.8
Uyama, C.9
-
6
-
-
0025457785
-
An electrohydraulic total artificial heart with a separately placed actuator
-
(1990)
Trans Am Soc Artif Intern Organs
, vol.36
-
-
Taenaka, Y.1
Sekii, H.2
Tatsumi, E.3
Nakatani, T.4
Sasaki, E.5
Yagura, A.6
Akagi, H.7
Masuzawa, T.8
Goto, M.9
Matsuo, Y.10
Takano, H.11
-
7
-
-
0001153402
-
Development of an electrohydraulic total artificial heart system
-
Akutsu T, Koyanagi H (eds) Heart replacement artificial heart 5. Tokyo: Springer-Verlag
-
(1996)
, pp. 101-107
-
-
Tatsumi, E.1
Taenaka, Y.2
Masuzawa, T.3
Choi, W.4
Toda, W.5
Miyazaki, K.6
Nakatani, T.7
Yagura, A.8
Baba, Y.9
Eya, K.10
Wakisaka, Y.11
Tominaga, M.E.12
Takano, H.13
Uyama, C.14
Koshiji, K.15
Nomura, T.16
Yasaki, T.17
Shu, E.18
Utsunomiya, T.19
Ohno, T.20
Fukui, Y.21
more..
-
8
-
-
10244261560
-
Set-up, improvement, and evaluation of an electrohydraulic total artificial heart with a separately placed energy converter
-
(1996)
ASAIO J
, vol.42
-
-
Masuzawa, T.1
Taenaka, Y.2
Tatsumi, E.3
Ahn, J.M.4
Ohno, T.5
Toda, K.6
Miyazaki, K.7
Wakisaka, Y.8
Eya, K.9
Baba, Y.10
Nakatani, T.11
Takano, H.12
Uyama, C.13
Koshiji, K.14
Fukui, Y.15
Takahashi, K.16
Tsuchimoto, K.17
Tsukahara, K.18
-
9
-
-
0027874618
-
Externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart
-
(1993)
Proc 15th Int IEEE Eng Med Biol
, pp. 909-910
-
-
Koshiji, K.1
Yazaki, T.2
Nomura, T.3
Shu, E.4
Utsunomiya, T.5
Niwa, S.6
Anai, H.7
Masuzawa, T.8
Taenaka, Y.9
Takano, H.10
-
10
-
-
18144441792
-
In vitro and in vivo evaluation of left-right balancing capacity of an interatrial shun in an electrohydraulic total artificial heart system
-
(1997)
ASAIO J
, vol.43
-
-
Tatsumi, E.1
Nakamura, M.2
Masuzawa, T.3
Taenaka, Y.4
Sohn, Y.5
Nishimura, T.6
Nakata, M.7
Nakatani, T.8
Ohno, T.9
Endo, S.10
Takiura, K.11
Takewa, Y.12
Kakuta, Y.13
Takano, H.14
-
11
-
-
0026498622
-
A blood pump with an interatrial shunt for use as an electrohydraulic total artificial heart
-
(1992)
ASAIO J
, vol.38
-
-
Tatsumi, E.1
Diegel, P.D.2
Holfelt, J.W.3
Dew, P.A.4
Crump, K.R.5
Hansen, A.C.6
Khanwilkar, P.S.7
Rowles, J.R.8
Olsen, D.B.9
-
14
-
-
18144445205
-
In vitro and in vivo heat dissipation of an electrohydraulic totally implantable artificial heart
-
(1997)
ASAIO J
, vol.43
-
-
Endo, S.1
Masuzawa, T.2
Tatsumi, E.3
Taenaka, Y.4
Nakatani, T.5
Ohno, T.6
Wakisaka, Y.7
Nishimura, T.8
Takewa, Y.9
Nakamura, M.10
Takiura, K.11
Sohn, Y.12
Takano, H.13
-
15
-
-
0034159225
-
In vitro and in vivo evaluation of silicone oil permeation through blood pump diaphragm in an electrohydraulic total artificial heart
-
(2000)
ASAIO J
, vol.46
, pp. 169
-
-
Tatsumi, E.1
Taenaka, Y.2
Uesho, K.3
Nishinaka, T.4
Imada, K.5
Homma, A.6
Takano, H.7
Tsuchimoto, K.8
Tsukahara, K.9
-
16
-
-
0032170919
-
Characterization and optimization of the flow pattern inside a diaphragm blood pump based on flow visualization techniques
-
(1998)
ASAIO J
, vol.44
-
-
Nakata, M.1
Masuzawa, T.2
Tatsumi, E.3
Taenaka, Y.4
Nishimura, T.5
Tsukiya, T.6
Takano, H.7
Tsuchimoto, K.8
Ohba, K.9
|