-
1
-
-
0019126003
-
Use of the Hoffmann apparatus in the treatment of unstable tibial fractures
-
Lawyer, R. B. and Lubbers, L. M. Use of the Hoffmann apparatus in the treatment of unstable tibial fractures. J. Bone Jt Surg., 1980, 62-A, 1264-1273.
-
(1980)
J. Bone Jt Surg.
, vol.62
, pp. 1264-1273
-
-
Lawyer, R.B.1
Lubbers, L.M.2
-
2
-
-
0027516793
-
Effects of axial dynamization on bone healing
-
Eggcr, E. L., Gottsauncr-Wolf, F., Palmer, J., Aro, II. T. and Chao, E. Y. S. Effects of axial dynamization on bone healing. J. Ortlwp. Trauma, 1993, 34, 185-192.
-
(1993)
J. Ortlwp. Trauma
, vol.34
, pp. 185-192
-
-
Eggcr, E.L.1
Gottsauncr-Wolf, F.2
Palmer, J.3
Aro, I.I.T.4
Chao, E.Y.S.5
-
3
-
-
0021059815
-
Complications of external skeletal fixation
-
Green, S. A. Complications of external skeletal fixation. Clin. Ortlwp., 1983, 180, 109-116.
-
(1983)
Clin. Ortlwp.
, vol.180
, pp. 109-116
-
-
Green, S.A.1
-
4
-
-
0030004991
-
Open tibial fractures treated with the ex-fi-re external fixation system
-
Heiland, P., Boc, A., Molstcr, A. O., Solhcim, E. and Hordvik, M. Open tibial fractures treated with the ex-fi-re external fixation system. Clin. Ortlwp., 1996, 326, 209-220.
-
(1996)
Clin. Ortlwp.
, vol.326
, pp. 209-220
-
-
Heiland, P.1
Boc, A.2
Molstcr, A.O.3
Solhcim, E.4
Hordvik, M.5
-
5
-
-
0031451259
-
Fracture of the tibial diaphysis treated by external fixation and the axial alignment grid: A single surgeon's experience
-
Hay, S. M., Rickman, M. and Salch, M. Fracture of the tibial diaphysis treated by external fixation and the axial alignment grid: a single surgeon's experience. Injury, 1997, 28(7), 437-443.
-
(1997)
Injury
, vol.28
, Issue.7
, pp. 437-443
-
-
Hay, S.M.1
Rickman, M.2
Salch, M.3
-
6
-
-
33749201608
-
The influence of fixator stiffness on maturation and biomechanical properties of distraction callus after segmental transport
-
Canada
-
Claes, L., Sugcr, G., Laulc, J., Licner, U. and Kinzl, L. The influence of fixator stiffness on maturation and biomechanical properties of distraction callus after segmental transport. In Fifth Biennial Meeting of the International Society for Fracture Repair, Canada, 1996.
-
(1996)
Fifth Biennial Meeting of the International Society for Fracture Repair
-
-
Claes, L.1
Sugcr, G.2
Laulc, J.3
Licner, U.4
Kinzl, L.5
-
7
-
-
0022413393
-
The influence of induced micromovement upon the healing of experimental tibial fractures
-
Goodship, A. E. and Kenwright, J. The influence of induced micromovement upon the healing of experimental tibial fractures. J. Bone Jt Stirg., 1985, 67-B, 650-655.
-
(1985)
J. Bone Jt Stirg.
, vol.67
, pp. 650-655
-
-
Goodship, A.E.1
Kenwright, J.2
-
8
-
-
0025807515
-
Axial movement and tibial fractures
-
Kenwright, J., Richardson, J. B., Cunningham, J. L., White, S. H., Goodship, A. E., Adams, M. A., Magnusscn, P. A. and Ncwman, J. H. Axial movement and tibial fractures. J. Bone Jt Surg., 1991, 73-B, 654-659.
-
(1991)
J. Bone Jt Surg.
, vol.73
, pp. 654-659
-
-
Kenwright, J.1
Richardson, J.B.2
Cunningham, J.L.3
White, S.H.4
Goodship, A.E.5
Adams, M.A.6
Magnusscn, P.A.7
Ncwman, J.H.8
-
9
-
-
77049238959
-
The biomechanics of fracture healing
-
Yamagishi, M. and Yoshimura, Y. The biomechanics of fracture healing. J. Bone Jt Surg., 1955, 37-A, 1035-1068.
-
(1955)
J. Bone Jt Surg.
, vol.37 A
, pp. 1035-1068
-
-
Yamagishi, M.1
Yoshimura, Y.2
-
10
-
-
33749199978
-
Effects of instability on bone healing
-
Grundncs, O. and Rcikcras, O. Effects of instability on bone healing. Ada Ortlwp. Scand., 1993, 649(1), 50-54.
-
(1993)
Ada Ortlwp. Scand.
, vol.649
, Issue.1
, pp. 50-54
-
-
Grundncs, O.1
Rcikcras, O.2
-
11
-
-
0025303830
-
External fixation for open tibia fractures
-
Marsh, J. L. and Nepola, J. V. External fixation for open tibia fractures. Ortlwp. Rev., 1990, XIX(3), 273.
-
(1990)
Ortlwp. Rev.
, vol.19
, Issue.3
, pp. 273
-
-
Marsh, J.L.1
Nepola, J.V.2
-
12
-
-
85037300943
-
-
Orthopaedic manipulator for reduction and external fixation. European Patent Publication WO 92/02184
-
Campopiano, A. Orthopaedic manipulator for reduction and external fixation. European Patent Publication WO 92/02184, 1992.
-
(1992)
-
-
Campopiano, A.1
-
13
-
-
0028401518
-
Automatic reduction with a computer controlled external fixator
-
Viccconti, M., Andrisano, A. O., Toni, A. and Giunti, A. Automatic reduction with a computer controlled external fixator. Med. Engng Physics, 1994, 16, 143-149.
-
(1994)
Med. Engng Physics
, vol.16
, pp. 143-149
-
-
Viccconti, M.1
Andrisano, A.O.2
Toni, A.3
Giunti, A.4
-
14
-
-
0025163227
-
Treatment of malunions and malnon-unions of the femur and tibia by detailed preoperative planning and the Ilizarov technique
-
Palcy, D., Chaudray, M., Pirone, A. M., Lcntz, P. and Kautz, D. Treatment of malunions and malnon-unions of the femur and tibia by detailed preoperative planning and the Ilizarov technique. Ortlwp. Clin. North Am., 1990, 21, 667-691.
-
(1990)
Ortlwp. Clin. North Am.
, vol.21
, pp. 667-691
-
-
Palcy, D.1
Chaudray, M.2
Pirone, A.M.3
Lcntz, P.4
Kautz, D.5
-
15
-
-
0029055011
-
Indirect reduction and composite fixation of extra-articular proximal tibial fractures
-
Bolhofncr, B. R. Indirect reduction and composite fixation of extra-articular proximal tibial fractures. Clin. Ortlwp., 1995, 315, 75-83.
-
(1995)
Clin. Ortlwp.
, vol.315
, pp. 75-83
-
-
Bolhofncr, B.R.1
-
16
-
-
32444442488
-
External fixation of the tibia. a two fixator reduction technique
-
Munich, Germany
-
Tandon, S. C., Thomas, P. B. M. and Gregson, P. A. External fixation of the tibia. A two fixator reduction technique. In European Federation for Orthopaedics and Traumatology Conference, Munich, Germany, 1995.
-
(1995)
European Federation for Orthopaedics and Traumatology Conference
-
-
Tandon, S.C.1
Thomas, P.B.M.2
Gregson, P.A.3
-
17
-
-
0017076151
-
Prevention of infection in the treatment of one thousand and twenty five open fractures of long bones. Retrospective and prospective analysis
-
Gustillo, R. B. and Andcrson, J. T. Prevention of infection in the treatment of one thousand and twenty five open fractures of long bones. Retrospective and prospective analysis. J. Bone Jt Surg., 1976, 58-A, 453-458.
-
(1976)
J. Bone Jt Surg.
, vol.58 A
, pp. 453-458
-
-
Gustillo, R.B.1
Andcrson, J.T.2
-
18
-
-
0001382571
-
Fractures of the tibial shaft. a survey of 705 cases
-
Nicholl, E. A. Fractures of the tibial shaft. A survey of 705 cases. J. Bone Jt Surg., 1964, 46-B, 373-387.
-
(1964)
J. Bone Jt Surg.
, vol.46
, pp. 373-387
-
-
Nicholl, E.A.1
-
19
-
-
0019473805
-
External fixation for complicated tibial fractures
-
Edge, A. J. and Dcnham, R. A. External fixation for complicated tibial fractures. J. Bone Jt Surg., 1981, 63-B, 92-97.
-
(1981)
J. Bone Jt Surg.
, vol.63 B
, pp. 92-97
-
-
Edge, A.J.1
Dcnham, R.A.2
-
20
-
-
0020451698
-
Results of treatment using the Hoffman external fixator for fractures of the tibial diaphysis
-
Kimmcl, R. B. Results of treatment using the Hoffman external fixator for fractures of the tibial diaphysis. J. Trauma, 1982, 22, 960.
-
(1982)
J. Trauma
, vol.22
, pp. 960
-
-
Kimmcl, R.B.1
-
21
-
-
0021163855
-
The treatment of fractures with a dynamic axial fixator
-
De Bastiani, G., Aldeghcri, R. and Rcnzi Brivio, L. The treatment of fractures with a dynamic axial fixator. J. Bone Jt Surg., 1984, 66-B, 538-545.
-
(1984)
J. Bone Jt Surg.
, vol.66 B
, pp. 538-545
-
-
De Bastiani, G.1
Aldeghcri, R.2
Rcnzi Brivio, L.3
|