메뉴 건너뛰기




Volumn , Issue , 2000, Pages 419-421

Hidden Markov model in wavelet analysis of myocardial ischemia in rabbit

Author keywords

[No Author keywords available]

Indexed keywords

BIOLOGICAL ORGANS; BLOOD VESSELS; DISEASES; ELECTROCARDIOGRAPHY; MARKOV PROCESSES; MATHEMATICAL MODELS; MUSCLE; WAVELET TRANSFORMS;

EID: 0034481122     PISSN: 02766574     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (9)

References (13)
  • 1
    • 0031214616 scopus 로고    scopus 로고
    • Analysis of Abnormal Signals within the QRS Complex of the High-Resolution Electrocardiogram 1997
    • Gomis P, Jones DL, et al. Analysis of Abnormal Signals within the QRS Complex of the High-Resolution Electrocardiogram 1997. IEEE Trans BME; 44: 681-93.
    • IEEE Trans BME , vol.44 , pp. 681-693
    • Gomis, P.1    Jones, D.L.2
  • 2
    • 0032751917 scopus 로고    scopus 로고
    • Identification of the Occluded Artery in Patients with Myocardial Ischemia Induced by Prolonged Percutaneous Transluminal Coronary Angioplasty Using Traditional vs Transformed ECG-Based Indexes
    • Garcia J, Wagner G, Sornmo L, Laguna P. Identification of the Occluded Artery in Patients with Myocardial Ischemia Induced by Prolonged Percutaneous Transluminal Coronary Angioplasty Using Traditional vs Transformed ECG-Based Indexes. Comp Biomed Res 1999;32:470-482.
    • (1999) Comp Biomed Res , vol.32 , pp. 470-482
    • Garcia, J.1    Wagner, G.2    Sornmo, L.3    Laguna, P.4
  • 3
    • 0029582839 scopus 로고    scopus 로고
    • Analysis of High-Resolution ECG Changes during Percutaneous Transluminal Coronary Angioplasty 1995
    • Lander P, Gomis P, et al. Analysis of High-Resolution ECG Changes During Percutaneous Transluminal Coronary Angioplasty 1995. J Electrocardiol 28(Suppl):39-40.
    • J Electrocardiol , vol.28 , Issue.SUPPL. , pp. 39-40
    • Lander, P.1    Gomis, P.2
  • 4
    • 0029589968 scopus 로고    scopus 로고
    • Intra-QRS High-Frequency ECG Changes with Ischemia. Is It Possible to Evaluate These Changes Using the Signal-Averaged Holter ECG in Dogs?
    • Yakubo S, Ozawa Y, et al. Intra-QRS High-Frequency ECG Changes with Ischemia. Is It Possible to Evaluate These Changes Using the Signal-Averaged Holter ECG in Dogs? 1995 J Electrocardiol 28(Suppl): 234-8.
    • 1995 J Electrocardiol , vol.28 , Issue.SUPPL. , pp. 234-238
    • Yakubo, S.1    Ozawa, Y.2
  • 5
    • 0020734214 scopus 로고
    • An Introduction to the Application of the Theory of Probabilistic Functions of a Markov Process to Automatic Speech Recognation
    • Levinson SE, Rabiner LR, Sondhi MM. An Introduction to the Application of the Theory of Probabilistic Functions of a Markov Process to Automatic Speech Recognation. The Bell Syst. Tech. J 1983; 62:1035-74.
    • (1983) The Bell Syst. Tech. J , vol.62 , pp. 1035-1074
    • Levinson, S.E.1    Rabiner, L.R.2    Sondhi, M.M.3
  • 6
    • 0031238095 scopus 로고    scopus 로고
    • A Model of Dynamic Auditory Perception and Its Application to Robust Word Recognition
    • Strope B, Alwan A. A Model Of Dynamic Auditory Perception And Its Application To Robust Word Recognition. IEEE Trans SAP 1997; 5:451-464.
    • (1997) IEEE Trans SAP , vol.5 , pp. 451-464
    • Strope, B.1    Alwan, A.2
  • 7
    • 0032868608 scopus 로고    scopus 로고
    • A Characterization of HRV's Nonlinear Hidden Dynamics by Means of Markov Models
    • Silipo R, Deco G, Vergassola R, Gremigni C. A Characterization of HRV's Nonlinear Hidden Dynamics by Means of Markov Models. IEEE Trans BME 1999; 46:978-986.
    • (1999) IEEE Trans BME , vol.46 , pp. 978-986
    • Silipo, R.1    Deco, G.2    Vergassola, R.3    Gremigni, C.4
  • 8
    • 0025483033 scopus 로고
    • An Approach to Cardiac Arrhythmia Analysis Using Hidden Markov Models
    • Coast DA, Stren RM, Cano GC, Briller SA. An Approach to Cardiac Arrhythmia Analysis Using Hidden Markov Models. IEEE Trans BME 1990; 37:826-36.
    • (1990) IEEE Trans BME , vol.37 , pp. 826-836
    • Coast, D.A.1    Stren, R.M.2    Cano, G.C.3    Briller, S.A.4
  • 9
    • 33845868473 scopus 로고    scopus 로고
    • Classification on Electrocardiogram Using Hidden Markov Models
    • Vienna
    • Cheng WT, Chan KL. Classification on Electrocardiogram Using Hidden Markov Models. In: IEEE EMBS 1998. Vienna.
    • IEEE EMBS 1998
    • Cheng, W.T.1    Chan, K.L.2
  • 10
    • 0025767685 scopus 로고
    • Method and theory of monophasic action potential recording
    • Franz MR. Method and theory of monophasic action potential recording. Prog Cardiovasc Dis 1991; 33:347-368.
    • (1991) Prog Cardiovasc Dis , vol.33 , pp. 347-368
    • Franz, M.R.1
  • 12
    • 0032822165 scopus 로고    scopus 로고
    • Automatic Detection of Conduction Block Based on Time-Frequency Analysis of Unipolar Electrograms
    • Evans FG, Rogers JM, Smith WM. Automatic Detection of Conduction Block Based on Time-Frequency Analysis of Unipolar Electrograms. IEEE Trans BME 1999; 46:1090-97.
    • (1999) IEEE Trans BME , vol.46 , pp. 1090-1097
    • Evans, F.G.1    Rogers, J.M.2    Smith, W.M.3
  • 13
    • 0000702690 scopus 로고    scopus 로고
    • Ischemia-Induced Propagation Failure in the Heart
    • Zipes DP, Jalife J. W.B. Saunders Co.
    • Kleber AG, Fleischhauer J, Cascio WE. Ischemia-Induced Propagation Failure in the Heart. In: Zipes DP, Jalife J. Cardiac Electrophysiology 1995. W.B. Saunders Co., 174-181.
    • Cardiac Electrophysiology 1995 , pp. 174-181
    • Kleber, A.G.1    Fleischhauer, J.2    Cascio, W.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.