메뉴 건너뛰기




Volumn 20, Issue 4, 2000, Pages 263-300

Discrimination of ventricular and supraventricular tachycardia via discrimination algorithm PR Logic™ used in implantable dual chamber cardioverter/defibrillator Gem™ DR systems;Unterscheidung von ventrikulären und supraventrikulären tachykardien anhand des diskriminierungsalgorithmus PR Logic™ im implantierbaren zweikammer-cardioverter/defibrillator Gem™ DR

Author keywords

Atrial fibrillation; Dual chamber detection algorithm; Dual chamber ICDs; Inappropriate therapies; PR Logic

Indexed keywords

ALGORITHM; ARTICLE; ARTIFICIAL HEART PACEMAKER; ATRIOVENTRICULAR DISSOCIATION; AUTOMATION; CARDIOVERSION; DECISION MAKING; DEFIBRILLATOR; DIAGNOSTIC ACCURACY; DIAPHRAGM MOVEMENT; DIFFERENTIAL DIAGNOSIS; HEART ATRIUM FIBRILLATION; HEART ATRIUM FLUTTER; HEART CONDUCTION; HEART RATE; HEART VENTRICLE TACHYCARDIA; HUMAN; MUSCLE CONTRACTION; MUSCLE POTENTIAL; SINUS TACHYCARDIA; SUPRAVENTRICULAR TACHYCARDIA; T WAVE; TREATMENT FAILURE;

EID: 0034480982     PISSN: 01765175     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (14)
  • 1
    • 0030279289 scopus 로고    scopus 로고
    • Inadäquate therapien durch implantierbare cardioverter defibrillatoren - Inzidenz, ursachen, prädiktive faktoren und vermeidungsstrategien
    • (1996) Z Kardiol , vol.85 , pp. 809-819
    • Weber, M.1    Block, M.2    Brunn, J.3
  • 2
  • 3
    • 0000402060 scopus 로고    scopus 로고
    • Dual chamber sensing and detection for implantable cardioverter-defibrillators
    • st Century: The State of the Art. Chapter 17. Futura Publishing Co, Inc., Armonk, NY
    • (1998) , pp. 385-436
    • Olson, W.H.1
  • 6
    • 4243434169 scopus 로고    scopus 로고
    • Programmierung zusätzlicher erkennungskriterien
    • Wietholt D., Ulbricht L.F., Gülker H. (Hrsg.) Implantierbare Kardioverter-Defibrillatoren. Georg Thieme Verlag Stuttgart New York
    • (1997) , pp. 175-185
    • Neuzner, J.1
  • 9
    • 26444465114 scopus 로고    scopus 로고
    • Incidence of spontaneous atrial tachyarrhythmias in patients treated with a combined atrioventricular defibrillator
    • abstr.
    • (1998) Circ , vol.17
    • Jung, W.1    Wolpert, C.2    Tenzer, D.3
  • 10
    • 4243434168 scopus 로고    scopus 로고
    • Improved specificity and low atrial defibrillation thresholds: A safe and efficaciouse approach to concomittant atrial and ventricular tachyarrhythmias
    • abstr.
    • (1998) EHJ , vol.8
    • Wolpert, C.1    Jung, W.2    Spehl, S.3
  • 11
    • 0000604657 scopus 로고    scopus 로고
    • Does a dual chamber detection algorithm really improve discrimination between supraventricular and ventricular tachycadias in implantable cardioverter-defibrillators recipients?
    • abstr.
    • (1999) EHJ , vol.20 , Issue.8
    • Ricci, R.1    Altamura, G.2    Toscano, S.3
  • 14
    • 0028306220 scopus 로고
    • Discrimination of ventricular tachycardia from sinus tachycardia and atrial fibrillation in a tiered therapy cadioverter defibrillator
    • (1994) JACC , vol.23 , pp. 1342-1355
    • Swerdlow, C.D.1    Cheng, P.S.2    Kass, M.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.