Volumn 4, Issue , 2000, Pages 3148-3151

An estimate of the perturbing effect of Cerenkov radiation to the signal from a liquid scintillator volume irradiated by a megavoltage photon beam

Author keywords

Cerenkov radiation; Dosimetry; Liquid scintillator

Indexed keywords

CERENKOV COUNTERS; DOSIMETRY; IMAGING TECHNIQUES; IRRADIATION; LIGHT EMISSION; PARTICLE BEAMS; PERTURBATION TECHNIQUES; PHOSPHORS; PHOTONS; POISSON DISTRIBUTION; REFRACTIVE INDEX; TOMOGRAPHY;

EID: 0034441320     PISSN: 05891019     EISSN: None     Source Type: Journal    
DOI: 10.1109/IEMBS.2000.901553     Document Type: Article
Times cited : (2)

References (7)
  • 3
    • 0026555508 scopus 로고
    • Cerenkov light generated in optical fibers and other light pipes irradiated by electron beams
    • A.S. Beddar T.R. Mackie F.H. Attix Cerenkov light generated in optical fibers and other light pipes irradiated by electron beams Phys. Med. Biol. 37 925 935 1992
    • (1992) Phys. Med. Biol. , vol.37 , pp. 925-935
    • Beddar, A.S.1    Mackie, T.R.2    Attix, F.H.3
  • 4
    • 0027219790 scopus 로고
    • Optical filtering and spectral measurements of radiation-induced light in plastic scintillation dosimetry
    • S.F. de Boer A.S. Beddar J. A. Rawlinson Optical filtering and spectral measurements of radiation-induced light in plastic scintillation dosimetry Phys. Med. Biol. 38 945 958 1992
    • (1992) Phys. Med. Biol. , vol.38 , pp. 945-958
    • de Boer, S.F.1    Beddar, A.S.2    Rawlinson, J.A.3
  • 5
    • 0000873460 scopus 로고    scopus 로고
    • Phosphorescent plastic fiber scintillators for radiation therapy dosimetry
    • K.J. Jordan Phosphorescent plastic fiber scintillators for radiation therapy dosimetry Med. Phys. 24 1004 1997
    • (1997) Med. Phys. , vol.24 , pp. 1004
    • Jordan, K.J.1
  • 6
    • 21344462306 scopus 로고    scopus 로고
    • A robust algorithm for spikes elimination from 2D CCD low-level light output measurements in the presence of ionizing radiation field
    • S. Devic A. S. Kirov J. F. Williamson Z. Piao J. F. Dempsey A robust algorithm for spikes elimination from 2D CCD low-level light output measurements in the presence of ionizing radiation field Med. Phys. 26 1161 1999
    • (1999) Med. Phys. , vol.26 , pp. 1161
    • Devic, S.1    Kirov, A.S.2    Williamson, J.F.3    Piao, Z.4    Dempsey, J.F.5
  • 7
    • 85177106793 scopus 로고
    • Nuclear Techniques and Their Uses
    • Wiley new York
    • B.J. Moyer Nuclear Techniques and Their Uses 1 1962 Wiley new York
    • (1962) , vol.1
    • Moyer, B.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.