메뉴 건너뛰기




Volumn 86, Issue 6, 2000, Pages 1000-1010

A European comparison of medical ultrasonic field measurements: Interpreting IEC 61157

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTIC FIELDS; ACOUSTIC IMAGING; ACOUSTOOPTICAL EFFECTS; ULTRASONIC DEVICES;

EID: 0034428753     PISSN: 00017884     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (12)
  • 3
    • 0039432627 scopus 로고    scopus 로고
    • An assessment of medical ultrasonic field measurement methods: Final technical report for EC contract no. MAT1-CT940064
    • National Physical Laboratory, UK
    • T. J. Esward: An assessment of medical ultrasonic field measurement methods: final technical report for EC contract no. MAT1-CT940064. NPL Report CMAM 17, National Physical Laboratory, UK, 1998.
    • (1998) NPL Report CMAM , vol.17
    • Esward, T.J.1
  • 4
    • 0032909512 scopus 로고    scopus 로고
    • Intercomparison of acoustic output measurements of a diagnostic ultrasound device
    • K. Beissner: Intercomparison of acoustic output measurements of a diagnostic ultrasound device. Ultrasound. Med. Biol. 25 (1999) 629-636.
    • (1999) Ultrasound. Med. Biol. , vol.25 , pp. 629-636
    • Beissner, K.1
  • 5
    • 0039575672 scopus 로고
    • A comparison of the frequency response of membrane and needle-probe pvdf hydrophones
    • Report no.57. D. H. Evans, K. Martin (eds.). Institute of Physical Sciences in Medicine, York, United Kingdom
    • S. P. Robinson: A comparison of the frequency response of membrane and needle-probe pvdf hydrophones. - In: Physics in medical ultrasound II. Report no.57. D. H. Evans, K. Martin (eds.). Institute of Physical Sciences in Medicine, York, United Kingdom, 1988, 79-86.
    • (1988) Physics in Medical Ultrasound II , pp. 79-86
    • Robinson, S.P.1
  • 8
    • 0022467241 scopus 로고
    • Harmonic distortion of a finite amplitude gaussian beam in a fluid
    • G. Du, M. A. Breazeale: Harmonic distortion of a finite amplitude gaussian beam in a fluid. J. Acoust. Soc. Am. 80 (1986) 212-216.
    • (1986) J. Acoust. Soc. Am. , vol.80 , pp. 212-216
    • Du, G.1    Breazeale, M.A.2
  • 9
    • 0026733535 scopus 로고
    • The influence of waveform distortion on hydrophone spatial-averaging corrections - Theory and measurement
    • B. Zeqiri, A. D. Bond: The influence of waveform distortion on hydrophone spatial-averaging corrections - Theory and measurement. J. Acoust. Soc. Am. 94 (1992) 1809-1821.
    • (1992) J. Acoust. Soc. Am. , vol.94 , pp. 1809-1821
    • Zeqiri, B.1    Bond, A.D.2
  • 10
    • 0019925765 scopus 로고
    • Characteristics of a pvdf membrane hydrophone for use in the range from 1-100 MHz
    • D. R. Bacon: Characteristics of a pvdf membrane hydrophone for use in the range from 1-100 MHz. IEEE Transactions on Sonics and Ultrasonics SU-19 (1982) 18-25.
    • (1982) IEEE Transactions on Sonics and Ultrasonics , vol.SU-19 , pp. 18-25
    • Bacon, D.R.1
  • 11
    • 0027436990 scopus 로고
    • Towards a protocol for measurement of maximum spatial peak temporal average acoustic intensity from diagnostic b mode ultrasound scanners in the field
    • J. Henderson, K. Jago, K. Willson, T. A. Whittingham: Towards a protocol for measurement of maximum spatial peak temporal average acoustic intensity from diagnostic b mode ultrasound scanners in the field. Phys. Med. Biol. 38 (1993) 1161-1621.
    • (1993) Phys. Med. Biol. , vol.38 , pp. 1161-1621
    • Henderson, J.1    Jago, K.2    Willson, K.3    Whittingham, T.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.