메뉴 건너뛰기




Volumn 26, Issue 11, 2000, Pages 660-664

A comparative scanning electron microscopic investigation of the efficacy of manual and automated instrumentation of root canals

Author keywords

[No Author keywords available]

Indexed keywords

DENTAL ALLOY; NICKEL; TITANIUM; TITANIUM NICKELIDE;

EID: 0034331016     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004770-200011000-00007     Document Type: Article
Times cited : (70)

References (20)
  • 1
    • 0028441507 scopus 로고
    • Consensus report of the European Society of endodontology on quality guidelines for endodontic treatment
    • European Society of Endodontology. Consensus report of the European Society of endodontology on quality guidelines for endodontic treatment. Int Endod J 1994;27:115-24.
    • (1994) Int Endod J , vol.27 , pp. 115-124
  • 2
    • 85031539832 scopus 로고    scopus 로고
    • Glossary
    • Chicago: American Association of Endodontists
    • American Association of Endodontists, ed. Glossary. Contemporary terminology for endodontics. 6th ed. Chicago: American Association of Endodontists, 1998.
    • (1998) Contemporary Terminology for Endodontics. 6th Ed.
  • 3
    • 0019086836 scopus 로고
    • Scanning electron microscope comparisons of the efficacy of various methods of root canal preparation
    • Bolanos OR, Jensen JR. Scanning electron microscope comparisons of the efficacy of various methods of root canal preparation. J Endodon 1980;6:815-22.
    • (1980) J Endodon , vol.6 , pp. 815-822
    • Bolanos, O.R.1    Jensen, J.R.2
  • 4
    • 0024051784 scopus 로고
    • Effectiveness of four methods for preparing root canals: A scanning electron microscopic evaluation
    • Haikel Y, Allemann C. Effectiveness of four methods for preparing root canals: a scanning electron microscopic evaluation. J Endodon 1988;14:340-5.
    • (1988) J Endodon , vol.14 , pp. 340-345
    • Haikel, Y.1    Allemann, C.2
  • 5
    • 0031129626 scopus 로고    scopus 로고
    • Root canal cleanliness after preparation with different endodontic handpieces and hand instruments: A comparative SEM investigation
    • Hülsmann M, Rümmelin C, Schäfers F. Root canal cleanliness after preparation with different endodontic handpieces and hand instruments: a comparative SEM investigation. J Endodon 1997;23:301-6.
    • (1997) J Endodon , vol.23 , pp. 301-306
    • Hülsmann, M.1    Rümmelin, C.2    Schäfers, F.3
  • 6
    • 0016562279 scopus 로고
    • A scanning electron microscopic study of the efficacy of various endodontic instruments
    • Mizrahi SJ, Tucker JW, Seltzer S. A scanning electron microscopic study of the efficacy of various endodontic instruments. J Endodon 1975;1:324-33.
    • (1975) J Endodon , vol.1 , pp. 324-333
    • Mizrahi, S.J.1    Tucker, J.W.2    Seltzer, S.3
  • 7
    • 0141903004 scopus 로고    scopus 로고
    • Comparative qualitative SEM study of automated vs. hand instrumentation of root canals
    • Schwarze T, Geurtsen W. Comparative qualitative SEM study of automated vs. hand instrumentation of root canals. Dtsch Zahnärztl Z 1996;51:227-30.
    • (1996) Dtsch Zahnärztl Z , vol.51 , pp. 227-230
    • Schwarze, T.1    Geurtsen, W.2
  • 8
    • 0030622179 scopus 로고    scopus 로고
    • A comparison of stainless steel Flexofiles and nickel-titanium NiTiFlex files during the shaping of simulated canals
    • Bishop K, Dummer PMH. A comparison of stainless steel Flexofiles and nickel-titanium NiTiFlex files during the shaping of simulated canals. Int Endod J 1997;30:25-34.
    • (1997) Int Endod J , vol.30 , pp. 25-34
    • Bishop, K.1    Dummer, P.M.H.2
  • 9
    • 0030622331 scopus 로고    scopus 로고
    • Shaping ability of ProFile .04 taper series 29 rotary nickel-titanium instruments in simulated canals. Parts 1 and 2
    • Thompson SA, Dummer PMH. Shaping ability of ProFile .04 taper series 29 rotary nickel-titanium instruments in simulated canals. Parts 1 and 2. Int Endod J 1997;30:1-15.
    • (1997) Int Endod J , vol.30 , pp. 1-15
    • Thompson, S.A.1    Dummer, P.M.H.2
  • 10
    • 0031990203 scopus 로고    scopus 로고
    • An in vitro evaluation of canal preparation using Profile .04 and .06 taper instruments
    • Kavanagh D, Lumley PJ. An in vitro evaluation of canal preparation using Profile .04 and .06 taper instruments. Endod Dent Traumatol 1998;14:16-20.
    • (1998) Endod Dent Traumatol , vol.14 , pp. 16-20
    • Kavanagh, D.1    Lumley, P.J.2
  • 11
    • 0031174825 scopus 로고    scopus 로고
    • Shaping ability of NT engine and McXim rotary nickel-titanium instruments in simulated canals. Part 1
    • Thompson SA, Dummer PMH. Shaping ability of NT engine and McXim rotary nickel-titanium instruments in simulated canals. Part 1. Int Endod J 1997;30:262-9.
    • (1997) Int Endod J , vol.30 , pp. 262-269
    • Thompson, S.A.1    Dummer, P.M.H.2
  • 12
    • 0015109962 scopus 로고
    • A comparison of canal preparations in straight and curved canals
    • Schneider SW. A comparison of canal preparations in straight and curved canals. Oral Surg Oral Med Oral Pathol 1971;32:271-5.
    • (1971) Oral Surg Oral Med Oral Pathol , vol.32 , pp. 271-275
    • Schneider, S.W.1
  • 13
    • 0002065098 scopus 로고
    • Cleaning and shaping the root canal system
    • Cohen S, Bums RC, eds. St. Louis: Mosby Year Book
    • West JD, Roane JB, Goerig AC. Cleaning and shaping the root canal system. In: Cohen S, Bums RC, eds. Pathways of the pulps. 6th ed. St. Louis: Mosby Year Book, 1994:179-218.
    • (1994) Pathways of the Pulps. 6th Ed. , pp. 179-218
    • West, J.D.1    Roane, J.B.2    Goerig, A.C.3
  • 14
    • 0023394904 scopus 로고
    • Tightness of root canal sealers with and without smear layer
    • Petschelt A, Stumpf B, Raab W. Tightness of root canal sealers with and without smear layer. Dtsch Zahnärztl Z 1987;42:743-6.
    • (1987) Dtsch Zahnärztl Z , vol.42 , pp. 743-746
    • Petschelt, A.1    Stumpf, B.2    Raab, W.3
  • 15
    • 0029355983 scopus 로고
    • Properties of endodontic hand instruments used in rotary motion. Part 1. Cutting efficiency
    • Tepel J, Schäfer E, Hoppe W. Properties of endodontic hand instruments used in rotary motion. Part 1. Cutting efficiency. J Endodon 1995;21:418-21.
    • (1995) J Endodon , vol.21 , pp. 418-421
    • Tepel, J.1    Schäfer, E.2    Hoppe, W.3
  • 16
    • 0029384145 scopus 로고
    • Properties of endodontic hand instruments used in rotary motion. Part 2. Instrumentation of curved canals
    • Schäfer E, Tepel J, Hoppe W. Properties of endodontic hand instruments used in rotary motion. Part 2. Instrumentation of curved canals. J Endodon 1995;21:493-7.
    • (1995) J Endodon , vol.21 , pp. 493-497
    • Schäfer, E.1    Tepel, J.2    Hoppe, W.3
  • 17
    • 0024657498 scopus 로고
    • SEM studies on root canal preparation using ultrasound
    • Beer R, Gängler P. SEM studies on root canal preparation using ultrasound. Dtsch Zahnärztl Z 1989;44:334-9.
    • (1989) Dtsch Zahnärztl Z , vol.44 , pp. 334-339
    • Beer, R.1    Gängler, P.2
  • 18
    • 0024758751 scopus 로고
    • The dentin-removing characteristics of an ultrasonic energized K-file
    • Briggs P, Gulabivala K, Stock C, Setchell D. The dentin-removing characteristics of an ultrasonic energized K-file. Int Endod J 1989;22:259-66.
    • (1989) Int Endod J , vol.22 , pp. 259-266
    • Briggs, P.1    Gulabivala, K.2    Stock, C.3    Setchell, D.4
  • 19
    • 0024659221 scopus 로고
    • The oscillatory pattern of sonically powered endodontic files
    • Walmsley A, Lumley P, Laird W. The oscillatory pattern of sonically powered endodontic files. Int Endod J 1989;22:125-32.
    • (1989) Int Endod J , vol.22 , pp. 125-132
    • Walmsley, A.1    Lumley, P.2    Laird, W.3
  • 20
    • 85031552503 scopus 로고    scopus 로고
    • Vergleichende rasterelektronenmikroskopische Untersuchung manuell und maschinell aufbereiteter Wurzelkanäle
    • in press
    • Schäfer E, Zapke K. Vergleichende rasterelektronenmikroskopische Untersuchung manuell und maschinell aufbereiteter Wurzelkanäle. Dtsch Zahnärztl Z (in press).
    • Dtsch Zahnärztl Z
    • Schäfer, E.1    Zapke, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.