Volumn 104, Issue 11, 2000, Pages 826-829

Clinical evaluation of the Heidelberg retina tomograph II

Author keywords

Heidelberg Retina Tomograph II; Measurement reproducibility; Optic disc parameters

Indexed keywords

ARTICLE; HISTOLOGY; HUMAN; INSTRUMENTATION; OPEN ANGLE GLAUCOMA; OPTIC DISK; RETINA; TOMOGRAPHY;

EID: 0034329412     PISSN: 00290203     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (7)
  • 1
    • 0027162051 scopus 로고
    • Reproducibility of topometric data acquisition in normal and glaucomatous optic nerve heads with the laser tomographic scanner
    • Rohrschneider K, Burk ROW, Volckcr H : Reproducibility of topometric data acquisition in normal and glaucomatous optic nerve heads with the laser tomographic scanner. Greafes Arch Clin Exp Ophthalmol 231 : 457-64, 1993.
    • (1993) Greafes Arch Clin Exp Ophthalmol , vol.231 , pp. 457-464
    • Rohrschneider, K.1    Burk, R.O.W.2    Volckcr, H.3
  • 2
    • 0024365201 scopus 로고
    • Quantitative assessment of optic nerve head with the laser tomographic scanner
    • Weinreb RN, Dreher AW, Bille J : Quantitative assessment of optic nerve head with the laser tomographic scanner. Int J Ophthalmol 13 : 25-9, 1989.
    • (1989) Int J Ophthalmol , vol.13 , pp. 25-29
    • Weinreb, R.N.1    Dreher, A.W.2    Bille, J.3
  • 3
    • 0027312137 scopus 로고
    • Reproducibility of topographic parameters obtained with the Heidelberg retina tomography
    • Mikelberg FS, Wijsman K, Schultz M : Reproducibility of topographic parameters obtained with the Heidelberg retina tomography. J Glaucoma 2 : 101-3, 1993.
    • (1993) J Glaucoma , vol.2 , pp. 101-103
    • Mikelberg, F.S.1    Wijsman, K.2    Schultz, M.3
  • 4
    • 0027404260 scopus 로고
    • Confocal scanning laser ophthalmoscope. Reproducibility of optic nerve head topographic measurement with the confocal scanning ophthalmoscope
    • Cioffi GA, Robin AL, Eastman RD, Perell HF, Sarfarazi FA, Kelman SE : Confocal scanning laser ophthalmoscope. Reproducibility of optic nerve head topographic measurement with the confocal scanning ophthalmoscope. Ophthalmology 100 : 57 -62.1993.
    • (1993) Ophthalmology , vol.100 , pp. 57-62
    • Cioffi, G.A.1    Robin, A.L.2    Eastman, R.D.3    Perell, H.F.4    Sarfarazi, F.A.5    Kelman, S.E.6
  • 5
    • 0029804465 scopus 로고    scopus 로고
    • Detection of structural damage from glaucoma with confocal scanning laser image analysis
    • Uchida H, Brigatti L, Caprioli J : Detection of structural damage from glaucoma with confocal scanning laser image analysis. Invest Ophthalmol Vis Sci 37:2393-2401,1996.
    • (1996) Invest Ophthalmol Vis Sci , vol.37 , pp. 2393-2401
    • Uchida, H.1    Brigatti, L.2    Caprioli, J.3
  • 6
    • 0030939485 scopus 로고    scopus 로고
    • Correlation between the visual field indices and Heidelberg Retina Tomograph parameters
    • Iester M, Mikelberg FS, Courtright P, Drance SM : Correlation between the visual field indices and Heidelberg Retina Tomograph parameters. Glaucoma 6 : 78-82, 1997.
    • (1997) Glaucoma , vol.6 , pp. 78-82
    • Iester, M.1    Mikelberg, F.S.2    Courtright, P.3    Drance, S.M.4
  • 7
    • 0031770658 scopus 로고    scopus 로고
    • Identification of early glaucoma cases with the scanning laser ophthalmoscope
    • Wollstein G, Garway-Heath DF, Hitching RA : Identification of early glaucoma cases with the scanning laser ophthalmoscope. Ophthalmology 105 : 1557-63, 1998.
    • (1998) Ophthalmology , vol.105 , pp. 1557-1563
    • Wollstein, G.1    Garway-Heath, D.F.2    Hitching, R.A.3