메뉴 건너뛰기




Volumn 147, Issue 1, 2000, Pages 116-120

Rapid Acquisition Transverse Relaxometric Imaging

Author keywords

EPI; Fast imaging; MRI; Relaxometry; T2

Indexed keywords

ANIMAL; ARTICLE; BRAIN MAPPING; ECHO PLANAR IMAGING; FEMALE; RAT; SPRAGUE DAWLEY RAT;

EID: 0034328583     PISSN: 10907807     EISSN: None     Source Type: Journal    
DOI: 10.1006/jmre.2000.2168     Document Type: Article
Times cited : (24)

References (23)
  • 1
    • 0026914023 scopus 로고
    • Practical T2 quantitation for clinical applications
    • C. S. Poon and R. M. Henkelman, Practical T2 quantitation for clinical applications. J. Magn. Reson. Imaging 2(5), 541-553, 1992.
    • (1992) J. Magn. Reson. Imaging , vol.2 , Issue.5 , pp. 541-553
    • Poon, C.S.1    Henkelman, R.M.2
  • 2
    • 0028338642 scopus 로고
    • In vivo visualization of myelin water in brain by magnetic resonance
    • A. MacKay, K. Whittall, J. Adler, D. Li, D. Paty, and D. Graeb, In vivo visualization of myelin water in brain by magnetic resonance. Magn. Reson. Med. 31(6), 673-677, 1994.
    • (1994) Magn. Reson. Med. , vol.31 , Issue.6 , pp. 673-677
    • MacKay, A.1    Whittall, K.2    Adler, J.3    Li, D.4    Paty, D.5    Graeb, D.6
  • 3
    • 0028980095 scopus 로고
    • T2 relaxation of peripheral nerve measured in vivo
    • M. D. Does and R. E. Snyder, T2 relaxation of peripheral nerve measured in vivo. Magn. Reson. Imaging 13(4), 575-580, 1995.
    • (1995) Magn. Reson. Imaging , vol.13 , Issue.4 , pp. 575-580
    • Does, M.D.1    Snyder, R.E.2
  • 4
    • 0032717481 scopus 로고    scopus 로고
    • In vivo measurements of multi-component T2 relaxation behaviour in guinea pig brain
    • P. J. Gareau, B. K. Rutt, C. V. Bowen, S. J. Karlik, and J. R. Mitchell, In vivo measurements of multi-component T2 relaxation behaviour in guinea pig brain. Magn. Reson. Imaging 17(9), 1319-1325, 1999.
    • (1999) Magn. Reson. Imaging , vol.17 , Issue.9 , pp. 1319-1325
    • Gareau, P.J.1    Rutt, B.K.2    Bowen, C.V.3    Karlik, S.J.4    Mitchell, J.R.5
  • 5
    • 0001649325 scopus 로고
    • A method for the simultaneous measurement of NMR spin-lattice and spin-spin relaxation times in compartmentalised systems
    • J. E. M. Snaar and H. Van As, A method for the simultaneous measurement of NMR spin-lattice and spin-spin relaxation times in compartmentalised systems. J. Magn. Reson. 99, 139-148, 1992.
    • (1992) J. Magn. Reson. , vol.99 , pp. 139-148
    • Snaar, J.E.M.1    Van As, H.2
  • 6
    • 0028987644 scopus 로고
    • Magnetization transfer and T2 relaxation components in tissue
    • R. Harrison, M. J. Bronskill, and R. M. Henkelman, Magnetization transfer and T2 relaxation components in tissue. Magn. Reson. Med. 33(4), 490-496, 1995.
    • (1995) Magn. Reson. Med. , vol.33 , Issue.4 , pp. 490-496
    • Harrison, R.1    Bronskill, M.J.2    Henkelman, R.M.3
  • 7
    • 0032217039 scopus 로고    scopus 로고
    • Multicomponent T1 relaxation and magnetisation transfer in peripheral nerve
    • M. D. Does, C. Beaulieu, P. S. Allen, and R. E. Snyder, Multicomponent T1 relaxation and magnetisation transfer in peripheral nerve. Magn. Reson. Imaging 16(9), 1033-1041, 1998.
    • (1998) Magn. Reson. Imaging , vol.16 , Issue.9 , pp. 1033-1041
    • Does, M.D.1    Beaulieu, C.2    Allen, P.S.3    Snyder, R.E.4
  • 8
    • 0031595078 scopus 로고    scopus 로고
    • Diffusional anisotropy of T2 components in bovine optic nerve
    • G. J. Stanisz and R. M. Henkelman, Diffusional anisotropy of T2 components in bovine optic nerve. Magn. Reson. Med. 40(3), 405-410, 1998.
    • (1998) Magn. Reson. Med. , vol.40 , Issue.3 , pp. 405-410
    • Stanisz, G.J.1    Henkelman, R.M.2
  • 10
    • 0032709387 scopus 로고    scopus 로고
    • Characterizing white matter with magnetization transfer and T(2)
    • G. J. Stanisz, A. Kecojevic, M. J. Bronskill, and R. M. Henkelman, Characterizing white matter with magnetization transfer and T(2). Magn. Reson. Med. 42(6), 1128-1136, 1999.
    • (1999) Magn. Reson. Med. , vol.42 , Issue.6 , pp. 1128-1136
    • Stanisz, G.J.1    Kecojevic, A.2    Bronskill, M.J.3    Henkelman, R.M.4
  • 11
    • 0034119890 scopus 로고    scopus 로고
    • Compartmental study of diffusion and relaxation measured in vivo in normal and ischaemic rat brain and trigeminal nerve
    • M. D. Does and J. C. Gore, Compartmental study of diffusion and relaxation measured in vivo in normal and ischaemic rat brain and trigeminal nerve. Magn. Reson. Med. 43(6), 837-844, 2000.
    • (2000) Magn. Reson. Med. , vol.43 , Issue.6 , pp. 837-844
    • Does, M.D.1    Gore, J.C.2
  • 15
    • 0029914967 scopus 로고    scopus 로고
    • MR measurement of relative water content and multicomponent T2 relaxation in human breast
    • S. J. Graham and M. J. Bronskill, MR measurement of relative water content and multicomponent T2 relaxation in human breast. Magn. Reson. Med. 35(5), 706-715, 1996.
    • (1996) Magn. Reson. Med. , vol.35 , Issue.5 , pp. 706-715
    • Graham, S.J.1    Bronskill, M.J.2
  • 16
    • 0032587952 scopus 로고    scopus 로고
    • Multicomponent T2 relaxation of in vivo skeletal muscle
    • G. Saab, R. T. Thompson, and G. D. Marsh, Multicomponent T2 relaxation of in vivo skeletal muscle. Magn. Reson. Med. 42(1), 150-157, 1999.
    • (1999) Magn. Reson. Med. , vol.42 , Issue.1 , pp. 150-157
    • Saab, G.1    Thompson, R.T.2    Marsh, G.D.3
  • 19
    • 0023164952 scopus 로고
    • Errors in T2 estimation using multislice multiple-echo imaging
    • A. P. Crawley and R. M. Henkelman, Errors in T2 estimation using multislice multiple-echo imaging. Magn. Reson. Med. 4(1), 34-47, 1987.
    • (1987) Magn. Reson. Med. , vol.4 , Issue.1 , pp. 34-47
    • Crawley, A.P.1    Henkelman, R.M.2
  • 20
    • 0027375577 scopus 로고
    • Ultrafast interleaved gradient-echo-planar imaging on a standard scanner
    • G. C. McKinnon, Ultrafast interleaved gradient-echo-planar imaging on a standard scanner. Magn. Reson. Med. 30, 609-616, 1993.
    • (1993) Magn. Reson. Med. , vol.30 , pp. 609-616
    • McKinnon, G.C.1
  • 21
    • 0003178190 scopus 로고
    • 180° refocussing pulses which are insensitive to static and radiofrequency field inhomogeniety
    • C. S. Poon and R. M. Henkelman, 180° refocussing pulses which are insensitive to static and radiofrequency field inhomogeniety. J. Magn. Reson. 99, 45, 1993.
    • (1993) J. Magn. Reson. , vol.99 , pp. 45
    • Poon, C.S.1    Henkelman, R.M.2
  • 22
    • 0001182288 scopus 로고
    • Quantitative interpretation of NMR relaxation data
    • K. P. Whittall and A. L. MacKay, Quantitative interpretation of NMR relaxation data. J. Magn. Reson. 84(1), 134-152, 1989.
    • (1989) J. Magn. Reson. , vol.84 , Issue.1 , pp. 134-152
    • Whittall, K.P.1    MacKay, A.L.2
  • 23
    • 0030033486 scopus 로고    scopus 로고
    • Criteria for analysis of multicomponent tissue T2 relaxation data
    • S. J. Graham, P. L. Stanchev, and M. J. Bronskill, Criteria for analysis of multicomponent tissue T2 relaxation data. Magn. Reson. Med. 35(3), 370-378, 1996.
    • (1996) Magn. Reson. Med. , vol.35 , Issue.3 , pp. 370-378
    • Graham, S.J.1    Stanchev, P.L.2    Bronskill, M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.