Volumn 17, Issue 11, 2000, Pages 1993-2000

Cone-beam reconstruction by backprojection and filtering

Author keywords

[No Author keywords available]

Indexed keywords

CYLINDERS (SHAPES); NUMERICAL METHODS; OBJECT RECOGNITION; OPTICAL FILTERS; OPTICAL TRANSFER FUNCTION; PROJECTION SYSTEMS;

EID: 0034320125     PISSN: 10847529     EISSN: 15208532     Source Type: Journal    
DOI: 10.1364/JOSAA.17.001993     Document Type: Article
Times cited : (9)

References (33)
  • 1
    • 0023677772 scopus 로고
    • SPECT using a specially designed cone beam collimator
    • R. J. Jaszczak, K. L. Greer, and R. E. Coleman, “SPECT using a specially designed cone beam collimator,” J. Nucl. Med. 29, 1398-1405 (1988).
    • (1988) J. Nucl. Med , vol.29 , pp. 1398-1405
    • Jaszczak, R.J.1    Greer, K.L.2    Coleman, R.E.3
  • 2
    • 0026516366 scopus 로고
    • Review of convergent beam tomography in single photon emission computed tomography
    • G. Gullberg, G. Zeng, F. L. Datz, P. E. Christian, C. H. Tung, and H. T. Morgan, “Review of convergent beam tomography in single photon emission computed tomography,” Phys. Med. Biol. 37, 507-534 (1992).
    • (1992) Phys. Med. Biol , vol.37 , pp. 507-534
    • Gullberg, G.1    Zeng, G.2    Datz, F.L.3    Christian, P.E.4    Tung, C.H.5    Morgan, H.T.6
  • 3
    • 0028382666 scopus 로고
    • Cone-beam reconstruction by the use of Radon transform intermediate functions
    • R. Clack and M. Defrise, “Cone-beam reconstruction by the use of Radon transform intermediate functions,” J. Opt. Soc. Am. A 11, 580-585 (1993).
    • (1993) J. Opt. Soc. Am. A , vol.11 , pp. 580-585
    • Clack, R.1    Defrise, M.2
  • 5
    • 0005421105 scopus 로고
    • Recent developments in X-ray tomography
    • F. Natterer, “Recent developments in X-ray tomography,” Lect. Appl. Math. 30, 177-198 (1994).
    • (1994) Lect. Appl. Math , vol.30 , pp. 177-198
    • Natterer, F.1
  • 7
    • 0002018761 scopus 로고
    • Mathematical framework of cone-beam 3D reconstruction via the first derivative of the Radon transform
    • G. T. Herman, A. K. Louis, and F. Natterer, SpringerVerlag, Berlin
    • P. Grangeat, “Mathematical framework of cone-beam 3D reconstruction via the first derivative of the Radon transform,” Vol. 1497 of Lecture Notes in Mathematics, G. T. Herman, A. K. Louis, and F. Natterer, eds. (SpringerVerlag, Berlin, 1991), pp. 66-97.
    • (1991) Of Lecture Notes in Mathematics , vol.1497 , pp. 66-97
    • Grangeat, P.1
  • 9
    • 0025429744 scopus 로고
    • Cone-beam tomography: Recent advances and tutorial review
    • B. D. Smith, “Cone-beam tomography: Recent advances and tutorial review,” Opt. Eng. 29, 524-534 (1991).
    • (1991) Opt. Eng , vol.29 , pp. 524-534
    • Smith, B.D.1
  • 10
    • 0001585739 scopus 로고    scopus 로고
    • Wavelet-based image en-hancement in x-ray imaging and tomography
    • A. V. Bronnikov and G. Duifhuis, “Wavelet-based image en-hancement in x-ray imaging and tomography,” Appl. Opt. 37, 4437-4448 (1998).
    • (1998) Appl. Opt , vol.37 , pp. 4437-4448
    • Bronnikov, A.V.1    Duifhuis, G.2
  • 11
    • 0001195059 scopus 로고
    • On a problem of I. M. Gel’fand
    • A. A. Kirillov, “On a problem of I. M. Gel’fand,” Sov. Math. Dokl. 2, 268-269 (1961).
    • (1961) Sov. Math. Dokl , vol.2 , pp. 268-269
    • Kirillov, A.A.1
  • 12
    • 0020764170 scopus 로고
    • An inversion formula for cone-beam reconstruc-tion
    • H. K. Tuy, “An inversion formula for cone-beam reconstruc-tion,” SIAM J. Appl. Math. 43, 546-552 (1983).
    • (1983) SIAM J. Appl. Math , vol.43 , pp. 546-552
    • Tuy, H.K.1
  • 13
    • 0022026907 scopus 로고
    • Image reconstruction from cone-beam projections: Necessary and sufficient conditions and reconstruction methods
    • B. D. Smith, “Image reconstruction from cone-beam projections: Necessary and sufficient conditions and reconstruction methods,” IEEE Trans. Med. Imaging 4, 14-25 (1985).
    • (1985) IEEE Trans. Med. Imaging , vol.4 , pp. 14-25
    • Smith, B.D.1
  • 14
    • 0028260061 scopus 로고
    • Cone-beam tomography with discrete data sets
    • H. H. Barrett and H. Gifford, “Cone-beam tomography with discrete data sets,” Phys. Med. Biol. 39, 451-476 (1994).
    • (1994) Phys. Med. Biol , vol.39 , pp. 451-476
    • Barrett, H.H.1    Gifford, H.2
  • 15
    • 0023311265 scopus 로고
    • To- mographic reconstruction from experimentally obtained cone-beam projections
    • S. Webb, J. Sutcliffe, L. Burkinshow, and A. Horsman, “To- mographic reconstruction from experimentally obtained cone-beam projections,” IEEE Trans. Med. Imaging 6, 67-73 (1987).
    • (1987) IEEE Trans. Med. Imaging , vol.6 , pp. 67-73
    • Webb, S.1    Sutcliffe, J.2    Burkinshow, L.3    Horsman, A.4
  • 16
    • 0027618016 scopus 로고
    • A fully three-dimensional reconstruction algorithm with the nonstationary filter for improved single-orbit cone beam SPECT
    • Z. J. Cao and B. M. W. Tsui, “A fully three-dimensional reconstruction algorithm with the nonstationary filter for improved single-orbit cone beam SPECT,” IEEE Trans. Nucl. Sci. 40, 280-287 (1993).
    • (1993) IEEE Trans. Nucl. Sci , vol.40 , pp. 280-287
    • Cao, Z.J.1    Tsui, B.M.W.2
  • 17
    • 0025654010 scopus 로고
    • Feasible cone beam scanning methods for exact reconstruction in three-dimensional tomography
    • H. Kudo and T. Saito, “Feasible cone beam scanning methods for exact reconstruction in three-dimensional tomography,” J. Opt. Soc. Am. A 7, 2169-2183 (1990).
    • (1990) J. Opt. Soc. Am. A , vol.7 , pp. 2169-2183
    • Kudo, H.1    Saito, T.2
  • 18
    • 0028397603 scopus 로고
    • Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbits
    • H. Kudo and T. Saito, “Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbits,” IEEE Trans. Med. Imaging 13, 196-211 (1994).
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 196-211
    • Kudo, H.1    Saito, T.2
  • 19
    • 0026552271 scopus 로고
    • A cone-beam tomography algorithm for orthogonal circle-and-line orbit
    • G. Zeng and G. Gullberg, “A cone-beam tomography algorithm for orthogonal circle-and-line orbit,” Phys. Med. Biol. 37, 563-577 (1992).
    • (1992) Phys. Med. Biol , vol.37 , pp. 563-577
    • Zeng, G.1    Gullberg, G.2
  • 20
    • 0026544832 scopus 로고
    • Cone beam tomography with circular, elliptical and spiral orbits
    • X. Yan and R. M. Leahy, “Cone beam tomography with circular, elliptical and spiral orbits,” Phys. Med. Biol. 37, 493-506 (1992).
    • (1992) Phys. Med. Biol , vol.37 , pp. 493-506
    • Yan, X.1    Leahy, R.M.2
  • 22
    • 0028392621 scopus 로고
    • A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam back- projection
    • M. Defrise and R. Clack, “A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam back- projection,” IEEE Trans. Med. Imaging 13, 186-195 (1994).
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 186-195
    • Defrise, M.1    Clack, R.2
  • 24
    • 0032034230 scopus 로고    scopus 로고
    • An efficient Fourier method for 3-D Radon inversion in exact cone-beam CT reconstruction
    • S. Schaller, T. Flohr, and P. Steffen, “An efficient Fourier method for 3-D Radon inversion in exact cone-beam CT reconstruction,” IEEE Trans. Med. Imaging 17, 244-250 (1998).
    • (1998) IEEE Trans. Med. Imaging , vol.17 , pp. 244-250
    • Schaller, S.1    Flohr, T.2    Steffen, P.3
  • 25
    • 0031972423 scopus 로고    scopus 로고
    • Three-dimensional reconstruction from cone- beam data using an efficient Fourier technique combined with a special interpolation filter
    • M. Seger, “Three-dimensional reconstruction from cone- beam data using an efficient Fourier technique combined with a special interpolation filter,” Phys. Med. Biol. 43, 951-959 (1998).
    • (1998) Phys. Med. Biol , vol.43 , pp. 951-959
    • Seger, M.1
  • 26
    • 0031971976 scopus 로고    scopus 로고
    • Fast and stable cone-beam filtered backprojection method for non-planar orbits
    • H. Kudo and T. Saito, “Fast and stable cone-beam filtered backprojection method for non-planar orbits,” Phys. Med. Biol. 43, 747-760 (1998).
    • (1998) Phys. Med. Biol , vol.43 , pp. 747-760
    • Kudo, H.1    Saito, T.2
  • 27
    • 0032912554 scopus 로고    scopus 로고
    • Single-slice rebinning method for helical cone-beam CT
    • F. Noo, M. Defrise, and R. Clackdoyle, “Single-slice rebinning method for helical cone-beam CT,” Phys. Med. Biol. 44, 561-570 (1999).
    • (1999) Phys. Med. Biol , vol.44 , pp. 561-570
    • Noo, F.1    Defrise, M.2    Clackdoyle, R.3
  • 28
    • 84975594840 scopus 로고
    • Solution to the three-dimensional image reconstruction problem from two- dimensional parallel projections
    • M. Defrise, R. Clack, and D. Townsend, “Solution to the three-dimensional image reconstruction problem from two- dimensional parallel projections,” J. Opt. Soc. Am. A 10, 869-877 (1993).
    • (1993) J. Opt. Soc. Am. A , vol.10 , pp. 869-877
    • Defrise, M.1    Clack, R.2    Townsend, D.3
  • 29
    • 0018467242 scopus 로고
    • The reconstruction of fan-beam data by filtering the back-projection
    • G. Gullberg, “The reconstruction of fan-beam data by filtering the back-projection,” Comput. Graph. Image Process. 10, 30-47 (1979).
    • (1979) Comput. Graph. Image Process , vol.10 , pp. 30-47
    • Gullberg, G.1
  • 30
    • 0038503972 scopus 로고
    • The generalized back-projection theorem for cone beam projection data
    • F. Peyrin, “The generalized back-projection theorem for cone beam projection data,” IEEE Trans. Nucl. Sci. 32, 1512-1519 (1985).
    • (1985) IEEE Trans. Nucl. Sci , vol.32 , pp. 1512-1519
    • Peyrin, F.1
  • 31
    • 0028400620 scopus 로고
    • Weighted backprojec- tion approach to cone beam 3D projection reconstruction for truncated spherical detection geometry
    • Z. H. Cho, E. X. Wu, and S. K. Hilal, “Weighted backprojec- tion approach to cone beam 3D projection reconstruction for truncated spherical detection geometry,” IEEE Trans. Med. Imaging 13, 111-121 (1994).
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 111-121
    • Cho, Z.H.1    Wu, E.X.2    Hilal, S.K.3
  • 32
    • 0037490064 scopus 로고
    • Analysis of a cone beam x-ray tomographic system for different scanning modes
    • F. Peyrin, R. Goutte, and M. Amiel, “Analysis of a cone beam x-ray tomographic system for different scanning modes,” J. Opt. Soc. Am. A 9, 1554-1563 (1992).
    • (1992) J. Opt. Soc. Am. A , vol.9 , pp. 1554-1563
    • Peyrin, F.1    Goutte, R.2    Amiel, M.3
  • 33
    • 0001982145 scopus 로고
    • Computer implementation of image reconstruction formulas
    • G. T. Herman, Springer-Verlag, Berlin
    • S. W. Rowland, “Computer implementation of image reconstruction formulas,” in Image Reconstruction from Projections, G. T. Herman, ed. (Springer-Verlag, Berlin, 1979), pp. 9-79.
    • (1979) Image Reconstruction from Projections , pp. 9-79
    • Rowland, S.W.1