메뉴 건너뛰기




Volumn 2, Issue 4, 2000, Pages 333-338

The effects of orthostasis on the ventricular-evoked response

Author keywords

Orthostasis; Tilt table test; Ventricular evoked response

Indexed keywords

AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CLINICAL TRIAL; COMPARATIVE STUDY; DIZZINESS; EVOKED RESPONSE; FEMALE; FOLLOW UP; HEART BLOCK; HEART RATE; HEMODYNAMICS; HUMAN; MALE; MIDDLE AGED; MONITORING; PHYSIOLOGY; PROBABILITY; SENSITIVITY AND SPECIFICITY; STATISTICAL MODEL; TILT TABLE TEST;

EID: 0034305430     PISSN: 10995129     EISSN: None     Source Type: Journal    
DOI: 10.1053/eupc.2000.0119     Document Type: Article
Times cited : (3)

References (18)
  • 2
    • 0007367848 scopus 로고    scopus 로고
    • What is closed loop stimulation?
    • Schaldach M. What is closed loop stimulation? Prog Biomed Res. 2:1998;49.
    • (1998) Prog Biomed Res , vol.2 , pp. 49
    • Schaldach, M.1
  • 3
    • 0031753464 scopus 로고    scopus 로고
    • Interindividual comparison of different sensor principles for rate adaptive pacing
    • Malinowski K. Interindividual comparison of different sensor principles for rate adaptive pacing. Pacing Clin Electrophysiol. 21:1998;2209-2213.
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 2209-2213
    • Malinowski, K.1
  • 4
    • 0040869286 scopus 로고    scopus 로고
    • Clinical evaluation of a new DDD pacemaker with automatic capture control using the ventricular evoked response
    • Binner L, Brummer T, Hombach V. Clinical evaluation of a new DDD pacemaker with automatic capture control using the ventricular evoked response. Prog Biomed Res. 2:1997;69-72.
    • (1997) Prog Biomed Res , vol.2 , pp. 69-72
    • Binner, L.1    Brummer, T.2    Hombach, V.3
  • 5
    • 0002803085 scopus 로고    scopus 로고
    • CHARM - Computerised heart acute rejection monitoring
    • Hutten H, Schreier G, Kastner P. CHARM - Computerised heart acute rejection monitoring. Biomed Eng. 41:1996;35-40.
    • (1996) Biomed Eng , vol.41 , pp. 35-40
    • Hutten, H.1    Schreier, G.2    Kastner, P.3
  • 6
    • 0027714746 scopus 로고
    • Low polarisation pacing lead for detecting the ventricular evoked response
    • Bolz A, Hubmann M, Hardt R. Low polarisation pacing lead for detecting the ventricular evoked response. Med Prog Tech. 19:1993;129-137.
    • (1993) Med Prog Tech , vol.19 , pp. 129-137
    • Bolz, A.1    Hubmann, M.2    Hardt, R.3
  • 7
    • 0040869285 scopus 로고    scopus 로고
    • High resolution monitoring of intracardiac signals with a DDD-pacemaker
    • Dauer W, Fröhlich R, Müssig D. High resolution monitoring of intracardiac signals with a DDD-pacemaker. Prog Biomed Res. 4:1996;50-55.
    • (1996) Prog Biomed Res , vol.4 , pp. 50-55
    • Dauer, W.1    Fröhlich, R.2    Müssig, D.3
  • 8
    • 0026644445 scopus 로고
    • Comparison of unipolar and bipolar ventricular evoked responses
    • Baig MW, Cowan JC, Perrins EJ. Comparison of unipolar and bipolar ventricular evoked responses. Br Heart J. 68:1992;398-402.
    • (1992) Br Heart J , vol.68 , pp. 398-402
    • Baig, M.W.1    Cowan, J.C.2    Perrins, E.J.3
  • 9
    • 0006744219 scopus 로고    scopus 로고
    • Ein Myokardmodell zur Simulation rechtsventrikulär evozierter Reizantworten
    • Pössenberger A, Schreier G, Hutten H. Ein Myokardmodell zur Simulation rechtsventrikulär evozierter Reizantworten. Biomed Tech. 41:1996;642-643.
    • (1996) Biomed Tech , vol.41 , pp. 642-643
    • Pössenberger, A.1    Schreier, G.2    Hutten, H.3
  • 10
    • 0040275023 scopus 로고
    • Monitoring the adrenergic stimulation of the heart by analysis of the ventricular evoked response
    • Eichstaedt HC, de Vivie R, Fischer G. Monitoring the adrenergic stimulation of the heart by analysis of the ventricular evoked response. Pacing Clin Electrophysiol. 18:1995;1102.
    • (1995) Pacing Clin Electrophysiol , vol.18 , pp. 1102
    • Eichstaedt, H.C.1    De Vivie, R.2    Fischer, G.3
  • 11
    • 0029562345 scopus 로고
    • Effect of smooth, porous and fractal surface structure on the properties of an interface
    • Bolz A, Fröhlich R, Schmidt K. Effect of smooth, porous and fractal surface structure on the properties of an interface. J Mat Sci: Mat Med. 6:1995;844-848.
    • (1995) J Mat Sci: Mat Med , vol.6 , pp. 844-848
    • Bolz, A.1    Fröhlich, R.2    Schmidt, K.3
  • 12
    • 0031957177 scopus 로고    scopus 로고
    • Head-up suspension in humans: Effects on sympathetic vasomotor activity and cardiovascular responses
    • Shamsuzzaman ASM, Sugiyama Y, Kamiya A. Head-up suspension in humans: Effects on sympathetic vasomotor activity and cardiovascular responses. J Appl Physiol. 84:1998;1513-1519.
    • (1998) J Appl Physiol , vol.84 , pp. 1513-1519
    • Shamsuzzaman, A.S.M.1    Sugiyama, Y.2    Kamiya, A.3
  • 13
    • 0020215253 scopus 로고
    • Mechanisms of initial heart rate response to postural change
    • Borst J, Wieling W, van Brederode JFM. Mechanisms of initial heart rate response to postural change. Am J Physiol. 243:1982;H676-81.
    • (1982) Am J Physiol , vol.243 , pp. 676-81
    • Borst, J.1    Wieling, W.2    Van Brederode, J.F.M.3
  • 15
    • 0029901523 scopus 로고    scopus 로고
    • Cardiovascular reflex changes preceding episodes of vasovagal syncope in paediatric subjects
    • Bernardi L, Salvucci F, Leuzzi S. Cardiovascular reflex changes preceding episodes of vasovagal syncope in paediatric subjects. Clin Sci Colch. 91:1996;25-27.
    • (1996) Clin Sci Colch , vol.91 , pp. 25-27
    • Bernardi, L.1    Salvucci, F.2    Leuzzi, S.3
  • 16
    • 0040869284 scopus 로고    scopus 로고
    • Monitoring of antiarrhythmic drugs with the monophasic action potential and the ventricular evoked response
    • Merkely B, Gellér R, Jukas-Nafy A. Monitoring of antiarrhythmic drugs with the monophasic action potential and the ventricular evoked response. Prog Biomed Res. 4:1996;70-76.
    • (1996) Prog Biomed Res , vol.4 , pp. 70-76
    • Merkely, B.1    Gellér, R.2    Jukas-Nafy, A.3
  • 18
    • 0023378414 scopus 로고
    • The effects of distant cardiac electrical events on local activation in unipolar epicardial electrograms
    • Blanchard SM, Damiano R, Asano T. The effects of distant cardiac electrical events on local activation in unipolar epicardial electrograms. IEEE Trans Biomed Eng. 7:1987;539-546.
    • (1987) IEEE Trans Biomed Eng , vol.7 , pp. 539-546
    • Blanchard, S.M.1    Damiano, R.2    Asano, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.