메뉴 건너뛰기




Volumn 97, Issue 5, 2000, Pages 567-575

Estimation of water flow through cracked concrete under load

Author keywords

Coefficient of permeability to water; Flow; Shrinkage cracking; Wedge

Indexed keywords

CRACK INITIATION; ESTIMATION; FLOW MEASUREMENT; INTERFEROMETRY; LAMINAR FLOW; MATHEMATICAL MODELS; MECHANICAL PERMEABILITY; MECHANICAL TESTING; SHRINKAGE; STRUCTURAL DESIGN; STRUCTURAL LOADS; WATER;

EID: 0034286816     PISSN: 08893241     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (73)

References (21)
  • 15
    • 0003387776 scopus 로고    scopus 로고
    • Standard Test Method for Compressive Strength of Cylindrical SpecimensDesignation C 39-94
    • "Standard Test Method for Compressive Strength of Cylindrical Specimens," Designation C 39-94, Annual Book of ASTM Standards, 04.02, pp. 17-21.
    • Annual Book of ASTM Standards, 04.02 , pp. 17-21
  • 16
    • 0003383068 scopus 로고    scopus 로고
    • Standard Test Method for Electrical Indication of Concrete's Ability to Resist Chloride Ion PenetrationDesignation C 1202-94
    • "Standard Test Method for Electrical Indication of Concrete's Ability to Resist Chloride Ion Penetration," Designation C 1202-94, Annual Book of ASTM Standards, 04.02, pp. 620-625.
    • Annual Book of ASTM Standards, 04.02 , pp. 620-625
  • 17
    • 0003345131 scopus 로고    scopus 로고
    • Standard Test Method for Splitting Tensile Strength of Cylindrical SpecimensDesignation C 496-90
    • "Standard Test Method for Splitting Tensile Strength of Cylindrical Specimens," Designation C 496-90, Annual Book of ASTM Standards, 04.02, pp. 266-269.
    • Annual Book of ASTM Standards, 04.02 , pp. 266-269


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.