메뉴 건너뛰기




Volumn 67, Issue 3, 2000, Pages 294-299

ISFET-based anion sensor for the potentiometric detection of organic acids in liquid chromatography

Author keywords

[No Author keywords available]

Indexed keywords

CARBOXYLIC ACIDS; FIELD EFFECT TRANSISTORS; ION EXCHANGE; LIQUID CHROMATOGRAPHY; NEGATIVE IONS; POLYVINYL CHLORIDES;

EID: 0034272956     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(00)00531-1     Document Type: Article
Times cited : (14)

References (27)
  • 1
    • 0027327912 scopus 로고
    • Determination by high-performance liquid chromatography of organic acids in Spanish rosé wines from the alpujarra-contraviesa region of Granada
    • Olalla Herrera M., López Garciá H., Villalón Mir M., López Martínez M.C. Determination by high-performance liquid chromatography of organic acids in Spanish rosé wines from the alpujarra-contraviesa region of Granada. J. Liq. Chromatogr. 16:1993;3101-3112.
    • (1993) J. Liq. Chromatogr. , vol.16 , pp. 3101-3112
    • Olalla Herrera, M.1    López Garciá, H.2    Villalón Mir, M.3    López Martínez, M.C.4
  • 2
    • 0000762352 scopus 로고    scopus 로고
    • HPLC analysis of organic acids in juice and wine using resin and reversed-phase columns
    • Dong M.W. HPLC analysis of organic acids in juice and wine using resin and reversed-phase columns. LC-GC. 16:1998;1092-1097.
    • (1998) LC-GC , vol.16 , pp. 1092-1097
    • Dong, M.W.1
  • 3
    • 0031690390 scopus 로고    scopus 로고
    • Retention behaviours and separation of carboxylic acids by ion-exchange chromatography
    • Hajós P., Nagy L. Retention behaviours and separation of carboxylic acids by ion-exchange chromatography. J. Chromatogr., B. 717:1998;27-38.
    • (1998) J. Chromatogr., B , vol.717 , pp. 27-38
    • Hajós, P.1    Nagy, L.2
  • 4
    • 0032906665 scopus 로고    scopus 로고
    • Determination of low molecular weight organic acids in soil solution by HPLC
    • Van Hees P.A.W., Dahlén J., Lundström U.S., Borén H., Allard B. Determination of low molecular weight organic acids in soil solution by HPLC. Talanta. 48:1999;173-179.
    • (1999) Talanta , vol.48 , pp. 173-179
    • Van Hees, P.A.W.1    Dahlén, J.2    Lundström, U.S.3    Borén, H.4    Allard, B.5
  • 5
    • 0029040466 scopus 로고
    • Potentiometric detection using a metallic copper electrode in reversed-phase and ion-exclusion chromatography with eluents containing ion-interaction reagents
    • Glod B.K., Alexander P.W., Haddad P.R., Chen Z.L. Potentiometric detection using a metallic copper electrode in reversed-phase and ion-exclusion chromatography with eluents containing ion-interaction reagents. J. Chromatogr., A. 699:1995;31-37.
    • (1995) J. Chromatogr., a , vol.699 , pp. 31-37
    • Glod, B.K.1    Alexander, P.W.2    Haddad, P.R.3    Chen, Z.L.4
  • 6
    • 0031128252 scopus 로고    scopus 로고
    • Determination of low-molecular-mass organic acids by capillary zone electrophoresis
    • Klampfl C.W., Buchberger W. Determination of low-molecular-mass organic acids by capillary zone electrophoresis. TrAC. 16:1997;221-229.
    • (1997) TrAC , vol.16 , pp. 221-229
    • Klampfl, C.W.1    Buchberger, W.2
  • 7
    • 0023120814 scopus 로고
    • Potentiometric detector for fast high-performance open-tubular column liquid chromatography
    • Manz A., Simon W. Potentiometric detector for fast high-performance open-tubular column liquid chromatography. Anal. Chem. 59:1987;74-79.
    • (1987) Anal. Chem. , vol.59 , pp. 74-79
    • Manz, A.1    Simon, W.2
  • 8
    • 0027244052 scopus 로고
    • Quantitative analysis in capillary zone electrophoresis using ion-selective microelectrodes as on-column detectors
    • Nann A., Silvestri I., Simon W. Quantitative analysis in capillary zone electrophoresis using ion-selective microelectrodes as on-column detectors. Anal. Chem. 65:1993;1662-1667.
    • (1993) Anal. Chem. , vol.65 , pp. 1662-1667
    • Nann, A.1    Silvestri, I.2    Simon, W.3
  • 9
    • 0030897402 scopus 로고    scopus 로고
    • Simultaneous amperometric and potentiometric detection of sugars, polyols and carboxylic acids in flow systems using copper wire electrodes
    • Chen Z.L., Hibbert D.B. Simultaneous amperometric and potentiometric detection of sugars, polyols and carboxylic acids in flow systems using copper wire electrodes. J. Chromatogr. A. 766:1997;27-33.
    • (1997) J. Chromatogr. a , vol.766 , pp. 27-33
    • Chen, Z.L.1    Hibbert, D.B.2
  • 10
    • 0031562054 scopus 로고    scopus 로고
    • Liquid chromatography of carboxylic acids using potentiometric detection with a tungsten oxide electrode
    • Chen Z.L., Alexander P.W., Haddad P.R. Liquid chromatography of carboxylic acids using potentiometric detection with a tungsten oxide electrode. Anal. Chim. Acta. 338:1997;41-49.
    • (1997) Anal. Chim. Acta , vol.338 , pp. 41-49
    • Chen, Z.L.1    Alexander, P.W.2    Haddad, P.R.3
  • 11
    • 0031442947 scopus 로고    scopus 로고
    • Potentiometric detection in capillary electrophoresis with a metallic copper electrode
    • Kappes T., Hauser P.C. Potentiometric detection in capillary electrophoresis with a metallic copper electrode. Anal. Chim. Acta. 354:1997;129-134.
    • (1997) Anal. Chim. Acta , vol.354 , pp. 129-134
    • Kappes, T.1    Hauser, P.C.2
  • 12
    • 0032164733 scopus 로고    scopus 로고
    • Capillary electrophoretic determination of different classes of organic ions by potentiometric detection with coated-wire ion-selective electrodes
    • Schnierle P., Kappes T., Hauser P.C. Capillary electrophoretic determination of different classes of organic ions by potentiometric detection with coated-wire ion-selective electrodes. Anal. Chem. 70:1998;3585-3589.
    • (1998) Anal. Chem. , vol.70 , pp. 3585-3589
    • Schnierle, P.1    Kappes, T.2    Hauser, P.C.3
  • 13
    • 0033002329 scopus 로고    scopus 로고
    • Potentiometric detection of monovalent anions separated by ion chromatography using all solid-state contact PVC matrix membrane electrode
    • Isildak I. Potentiometric detection of monovalent anions separated by ion chromatography using all solid-state contact PVC matrix membrane electrode. Chromatographia. 49:1999;338-342.
    • (1999) Chromatographia , vol.49 , pp. 338-342
    • Isildak, I.1
  • 14
    • 0028282641 scopus 로고
    • Potentiometric detection of organic acids in ion-exclusion chromatography using different types of liquid-membrane electrodes
    • De Backer B.L., Nagels L.J. Potentiometric detection of organic acids in ion-exclusion chromatography using different types of liquid-membrane electrodes. Anal. Chim. Acta. 290:1994;259-267.
    • (1994) Anal. Chim. Acta , vol.290 , pp. 259-267
    • De Backer, B.L.1    Nagels, L.J.2
  • 15
    • 0030415732 scopus 로고    scopus 로고
    • Potentiometric detection for capillary electrophoresis: Determination of organic acids
    • De Backer B.L., Nagels L.J. Potentiometric detection for capillary electrophoresis: determination of organic acids. Anal. Chem. 68:1996;4441-4445.
    • (1996) Anal. Chem. , vol.68 , pp. 4441-4445
    • De Backer, B.L.1    Nagels, L.J.2
  • 16
    • 0031828927 scopus 로고    scopus 로고
    • Potentiometric detection of organic acids in liquid chromatography using conducting oligomer electrodes
    • Poels I., Nagels L.J., Verreyt G., Geise H.J. Potentiometric detection of organic acids in liquid chromatography using conducting oligomer electrodes. Anal. Chim. Acta. 370:1998;105-113.
    • (1998) Anal. Chim. Acta. , vol.370 , pp. 105-113
    • Poels, I.1    Nagels, L.J.2    Verreyt, G.3    Geise, H.J.4
  • 17
    • 0032743576 scopus 로고    scopus 로고
    • Conducting polymer and oligomer micro-electrodes for the potentiometric detection of anions in capillary electrophoresis
    • Poels I., Nagels L.J. Conducting polymer and oligomer micro-electrodes for the potentiometric detection of anions in capillary electrophoresis. Anal. Chim. Acta. 401:1999;21-27.
    • (1999) Anal. Chim. Acta , vol.401 , pp. 21-27
    • Poels, I.1    Nagels, L.J.2
  • 18
    • 0000967898 scopus 로고    scopus 로고
    • Continuous-flow system for on-line water monitoring using back-side contact ISFET-based sensors
    • Jiménez C., Marqués I., Bartrolí J. Continuous-flow system for on-line water monitoring using back-side contact ISFET-based sensors. Anal. Chem. 68:1996;3801-3807.
    • (1996) Anal. Chem. , vol.68 , pp. 3801-3807
    • Jiménez, C.1    Marqués, I.2    Bartrolí, J.3
  • 19
    • 0026839319 scopus 로고
    • Flow-through pH-ISFET+reference-ISE as integrated detector in automated FIA determinations
    • Alegret S., Bartrolí J., Jimenez-Jorquera C., del Valle M. Flow-through pH-ISFET+reference-ISE as integrated detector in automated FIA determinations. Sens Actuators, B. 7:1992;555-560.
    • (1992) Sens Actuators, B , vol.7 , pp. 555-560
    • Alegret, S.1    Bartrolí, J.2    Jimenez-Jorquera, C.3    Del Valle, M.4
  • 21
    • 0001893153 scopus 로고
    • Analytical and biomedical application of ion-selective field effect transistors
    • Amsterdam: Elsevier
    • Bergveld P., Sibbald A. Analytical and biomedical application of ion-selective field effect transistors. Comprehensive Analytical Chemistry. vol. XXIII:1988;75-100 Elsevier, Amsterdam.
    • (1988) Comprehensive Analytical Chemistry , vol.23 , pp. 75-100
    • Bergveld, P.1    Sibbald, A.2
  • 22
    • 0024999436 scopus 로고
    • Convection/diffusion- And diffusion-controlled rapid-scan voltammetry in liquid chromatographic systems with a large-volume wall-jet detector
    • Nagels L.J., Kauffmann J.M., Dewaele C., Parmentier F. Convection/diffusion- and diffusion-controlled rapid-scan voltammetry in liquid chromatographic systems with a large-volume wall-jet detector. Anal. Chim. Acta. 234:1990;75-81.
    • (1990) Anal. Chim. Acta , vol.234 , pp. 75-81
    • Nagels, L.J.1    Kauffmann, J.M.2    Dewaele, C.3    Parmentier, F.4
  • 24
    • 0034194770 scopus 로고    scopus 로고
    • Potentiometric detection of carboxylic acids, phosphate esters and nucleotides in liquid chromatography using anion-selective coated-wire electrodes
    • Picioreanu S., Poels I., Frank J., van Dam J.C., van Dedem G.W.K., Nagels L.J. Potentiometric detection of carboxylic acids, phosphate esters and nucleotides in liquid chromatography using anion-selective coated-wire electrodes. Anal. Chem. 72:2000;2029-2034.
    • (2000) Anal. Chem. , vol.72 , pp. 2029-2034
    • Picioreanu, S.1    Poels, I.2    Frank, J.3    Van Dam, J.C.4    Van Dedem, G.W.K.5    Nagels, L.J.6
  • 25
    • 0028834386 scopus 로고
    • Single-run separation and detection of multiple metabolic intermediates by anion-exchange high-performance liquid chromatography and application to cell pool extracts prepared from Escherichia coli
    • Bhattacharya M., Fuhrman L., Ingram A., Nickerson K.W., Conway T. Single-run separation and detection of multiple metabolic intermediates by anion-exchange high-performance liquid chromatography and application to cell pool extracts prepared from Escherichia coli. Anal. Biochem. 232:1995;98-106.
    • (1995) Anal. Biochem. , vol.232 , pp. 98-106
    • Bhattacharya, M.1    Fuhrman, L.2    Ingram, A.3    Nickerson, K.W.4    Conway, T.5
  • 26
    • 0002378630 scopus 로고
    • Recommendations for publishing manuscripts on ion-selective electrodes
    • Guilbault G.G. Recommendations for publishing manuscripts on ion-selective electrodes. IUPAC Inf. Bull. 1:1978;69-74.
    • (1978) IUPAC Inf. Bull. , vol.1 , pp. 69-74
    • Guilbault, G.G.1
  • 27
    • 0029485029 scopus 로고
    • Proceedings of the 1995 IEEE Region 10 Annual International Conference on Microelectronics and VLSI, TENCON
    • Niu M., Ding X., Tao X., Lin W. Development of a novel micro FIA-ISFET integrated sensor. Proceedings of the 1995 IEEE Region 10 Annual International Conference on Microelectronics and VLSI, TENCON:1995;183-186.
    • (1995) Development of a Novel Micro FIA-ISFET Integrated Sensor , pp. 183-186
    • Niu, M.1    Ding, X.2    Tao, X.3    Lin, W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.