-
1
-
-
84951279351
-
The use of quartz oscillators for weighing thin layers and for microweighing
-
Sauerbrey G. The use of quartz oscillators for weighing thin layers and for microweighing. Z. Phys. 155:1959;206-222.
-
(1959)
Z. Phys.
, vol.155
, pp. 206-222
-
-
Sauerbrey, G.1
-
2
-
-
8144229066
-
Piezoelectric sorption detector
-
King W.H. Jr. Piezoelectric sorption detector. Anal. Chem. 36:1964;1735-1738.
-
(1964)
Anal. Chem.
, vol.36
, pp. 1735-1738
-
-
King W.H., Jr.1
-
3
-
-
0017556722
-
Applications of the piezoelectric crystal detector in analytical chemistry
-
Hlavay J., Guilbault G.G. Applications of the piezoelectric crystal detector in analytical chemistry. Anal. Chem. 49:1977;1890-1896.
-
(1977)
Anal. Chem.
, vol.49
, pp. 1890-1896
-
-
Hlavay, J.1
Guilbault, G.G.2
-
4
-
-
0022463399
-
Selection of adsorbates for chemical sensor arrays by pattern recognition
-
Carey W.P., Beebe K.R., Kowalski B.R. Selection of adsorbates for chemical sensor arrays by pattern recognition. Anal. Chem. 58:1986;149-153.
-
(1986)
Anal. Chem.
, vol.58
, pp. 149-153
-
-
Carey, W.P.1
Beebe, K.R.2
Kowalski, B.R.3
-
9
-
-
0001367472
-
QCM operation in liquids: Constant sensitivity during formation of extended protein multilayers by affinity
-
Rickert J., Brecht A., Gopel W. QCM operation in liquids: constant sensitivity during formation of extended protein multilayers by affinity. Anal. Chem. 69:1997;1441-1448.
-
(1997)
Anal. Chem.
, vol.69
, pp. 1441-1448
-
-
Rickert, J.1
Brecht, A.2
Gopel, W.3
-
10
-
-
4244029320
-
Quartz crystal microbalance study of immobilization and hybridization for nuceic acid sensor development
-
Caruso F., Rodda E., Furlong D.N. Quartz crystal microbalance study of immobilization and hybridization for nuceic acid sensor development. Anal. Chem. 69:1997;2043-2049.
-
(1997)
Anal. Chem.
, vol.69
, pp. 2043-2049
-
-
Caruso, F.1
Rodda, E.2
Furlong, D.N.3
-
11
-
-
0033013056
-
Preparation and application of a trimethoprim ion-selective piezoelectric sensor
-
Li W., Su X., Guo H., Wei W., Yao S. Preparation and application of a trimethoprim ion-selective piezoelectric sensor. Analyst. 124:1999;91-95.
-
(1999)
Analyst
, vol.124
, pp. 91-95
-
-
Li, W.1
Su, X.2
Guo, H.3
Wei, W.4
Yao, S.5
-
12
-
-
0031309847
-
Antibody binding to a functionalized supported lipid layer: A direct acoustic immunosensor
-
Gizeli E., Liley M., Lowe C.R., Vogel H. Antibody binding to a functionalized supported lipid layer: a direct acoustic immunosensor. Anal. Chem. 69:1997;4808-4813.
-
(1997)
Anal. Chem.
, vol.69
, pp. 4808-4813
-
-
Gizeli, E.1
Liley, M.2
Lowe, C.R.3
Vogel, H.4
-
13
-
-
0000827806
-
An enzymatic clay-modified electrode for aerobic glucose monitoring with dopamine as mediator
-
Zen J.M., Lo C.W., Chen P.J. An enzymatic clay-modified electrode for aerobic glucose monitoring with dopamine as mediator. Anal. Chem. 69:1997;1669-1673.
-
(1997)
Anal. Chem.
, vol.69
, pp. 1669-1673
-
-
Zen, J.M.1
Lo, C.W.2
Chen, P.J.3
-
14
-
-
0041127939
-
Cyclic polyethers and their complexes with metal salts
-
Pedersen C.J. Cyclic polyethers and their complexes with metal salts. J. Am. Chem. Soc. 89:1967;7017-7036.
-
(1967)
J. Am. Chem. Soc.
, vol.89
, pp. 7017-7036
-
-
Pedersen, C.J.1
-
15
-
-
25544460127
-
Application of macrocyclic compounds in chemical analysis
-
Kolthoff L.M. Application of macrocyclic compounds in chemical analysis. Anal. Chem. 51:1979;R1-R22.
-
(1979)
Anal. Chem.
, vol.51
-
-
Kolthoff, L.M.1
-
16
-
-
49349125924
-
Application of exchanger with crown ethers as anchor group in analytical and preparative chemistry
-
Cram D.J. Application of exchanger with crown ethers as anchor group in analytical and preparative chemistry. J. Chromatogr. 167:1978;307-320.
-
(1978)
J. Chromatogr.
, vol.167
, pp. 307-320
-
-
Cram, D.J.1
-
17
-
-
0004915554
-
Application of the bifunctional switch-type cryptand ion chromatographic stationary phase for ion separation
-
Tsai S.S., Shih J.S. Application of the bifunctional switch-type cryptand ion chromatographic stationary phase for ion separation. Sep. Sci. Technol. 33:1998;1407-1421.
-
(1998)
Sep. Sci. Technol.
, vol.33
, pp. 1407-1421
-
-
Tsai, S.S.1
Shih, J.S.2
-
18
-
-
1542743726
-
C60: Buckminsterfullerene
-
Kroto H.W., Heath J.R., O'Brien S.C., Curl R.F., Smalley R.E. C60: buckminsterfullerene. Nature. 318:1985;162-163.
-
(1985)
Nature
, vol.318
, pp. 162-163
-
-
Kroto, H.W.1
Heath, J.R.2
O'Brien, S.C.3
Curl, R.F.4
Smalley, R.E.5
-
19
-
-
0025187901
-
Solid: C60, a new form of carbon
-
Kraetschmer W., Lamb L.D., Fostiropoules K., Huffman D.R. Solid: C60, a new form of carbon. Nature. 347:1990;354-358.
-
(1990)
Nature
, vol.347
, pp. 354-358
-
-
Kraetschmer, W.1
Lamb, L.D.2
Fostiropoules, K.3
Huffman, D.R.4
-
21
-
-
0031668032
-
Adsorption study of organic molecules on fullerene with piezoelectric crystal detection system
-
Chao Y.C., Shih J.S. Adsorption study of organic molecules on fullerene with piezoelectric crystal detection system. Anal. Chim. Acta. 374:1998;39-46.
-
(1998)
Anal. Chim. Acta
, vol.374
, pp. 39-46
-
-
Chao, Y.C.1
Shih, J.S.2
-
22
-
-
0000870544
-
Kinetics of invertase action
-
Michaelis L., Menten M.L. Kinetics of invertase action. Biochem. Z. 49:1913;333-369.
-
(1913)
Biochem. Z.
, vol.49
, pp. 333-369
-
-
Michaelis, L.1
Menten, M.L.2
-
24
-
-
0032502264
-
Preparation and application of cryptand-coated piezoelectric crystal gas-chromatographic detector
-
Chang P., Shih J.S. Preparation and application of cryptand-coated piezoelectric crystal gas-chromatographic detector. Anal. Chim. Acta. 360:1998;61-68.
-
(1998)
Anal. Chim. Acta
, vol.360
, pp. 61-68
-
-
Chang, P.1
Shih, J.S.2
-
25
-
-
0033017260
-
Multifuctional cryptand coated piezoelectric quartz crystal detector for cations, anions and organic molecules
-
Chiou C.S., Shih J.S. Multifuctional cryptand coated piezoelectric quartz crystal detector for cations, anions and organic molecules. Anal. Chim. Acta. 392:1999;125-133.
-
(1999)
Anal. Chim. Acta
, vol.392
, pp. 125-133
-
-
Chiou, C.S.1
Shih, J.S.2
-
26
-
-
37049066414
-
Thickness-shear-mode acoustic wave sensors in the liquid phase, A review
-
Thompson M., Kipling A.L., Duncan-Hewitt W.C. Thickness-shear-mode acoustic wave sensors in the liquid phase, A review. Analyst. 116:1991;881.
-
(1991)
Analyst
, vol.116
, pp. 881
-
-
Thompson, M.1
Kipling, A.L.2
Duncan-Hewitt, W.C.3
-
27
-
-
0032908966
-
Application Of pizoelectric Ru(III)/cryptand coated quartz crystal gas chromatographic detector for olefins
-
Chang P., Shih J.S. Application Of pizoelectric Ru(III)/cryptand coated quartz crystal gas chromatographic detector for olefins. Anal. Chim. Acta. 380:1999;55-62.
-
(1999)
Anal. Chim. Acta
, vol.380
, pp. 55-62
-
-
Chang, P.1
Shih, J.S.2
|