Volumn 37, Issue 9, 2000, Pages 769-779
|
Development of under-sodium three-dimensional visual inspection technique using matrix-arrayed ultrasonic transducer
|
Author keywords
Cross correlation; FBR type reactors; Matrix arrayed ultrasonic transducer; Sodium; Synthetic aperture focusing; Ultrasonic visual inspection
|
Indexed keywords
FAST REACTORS;
FOCUSING;
IMAGE ANALYSIS;
IMAGE QUALITY;
OPTICAL CORRELATION;
SODIUM;
ULTRASONIC TRANSDUCERS;
VISUALIZATION;
MATRIX-ARRAYED ULTRASONIC TRANSDUCERS;
SYNTHETIC APERTURE FOCUSING;
THREE-DIMENSIONAL VISUAL INSPECTION METHOD;
BREEDER REACTORS;
|
EID: 0034268832
PISSN: 00223131
EISSN: None
Source Type: Journal
DOI: 10.1080/18811248.2000.9714955 Document Type: Article |
Times cited : (49)
|
References (8)
|