Comparison of tc-99m-labelled antileukocyte fragment fab′ and tc-99m-hmpao leukocyte scintigraphy in the diagnosis of bone and joint infections: a prospective study
Immunoscintigraphy of inflammatory processes with a technetium-99m-labeled monoclonal antigranulocyte antibody (Mab BW 250183).
Lind P, Langsteger W, Kaltringer P et al. Immunoscintigraphy of inflammatory processes with a technetium-99m-labeled monoclonal antigranulocyte antibody (Mab BW 250/183). J Nucl Med 1990; 32: 417-423.
Detection of infection in post operative orthopedic patients with technetium-99m-labeled monoclonal antibodies against granulocytes.
Reuland P, Winker KH, Hazchere T et al. Detection of infection in post operative orthopedic patients with technetium-99m-labeled monoclonal antibodies against granulocytes. J Nucl Med 1991; 32: 2209-2214.
Use of technetium antigranulocyte monoclonal antibody Fab fragments for the detction of osteomyelitis.
Hardwood SJ, Camblin JG, Hakki S et al. Use of technetium antigranulocyte monoclonal antibody Fab′ fragments for the detction of osteomyelitis. Cell Biophys 1994; 24-25: 99-107.
Comparison of technetium 99m Immuno-RAID-MN3 antigranulocyte MAb Fab fragments and In-111 WBCs for detection of osteomyelitis. Proceedings of 41st Annual Meeting of Society of Nuclear Medicine.
Hardwood SJ, Camblin JG, Morrissey MA et al. Comparison of technetium 99m Immuno-RAID-MN3 antigranulocyte MAb Fab′ fragments and In-111 WBCs for detection of osteomyelitis. Proceedings of 41st Annual Meeting of Society of Nuclear Medicine. J Nucl Med 1994; 35: 89P.
Detection of soft-tissue infections and osteomyelitis using a technetium 99m labeled anti-granulocyte monoclonal antibody fragment.
Becker W, Bair J, Behr T et al. Detection of soft-tissue infections and osteomyelitis using a technetium 99m labeled anti-granulocyte monoclonal antibody fragment. J Nucl Med 1994; 35: 1436-1443.
Comparative study of monoclonal antibody scan in diagnosing orthopaedic infection.
Hakki S, Harwood SJ, Morrissey MA et al. Comparative study of monoclonal antibody scan in diagnosing orthopaedic infection. Clin Orthop Reas 1997; 335: 275-285.
Technetium-99m hexamethylpropylene amine oxime leucocyte scintigraphy for the diagnosis of bone and joint infections: a retrospective study in 116 patients.
Devillers A, Moisan A, Jean S et al. Technetium-99m hexamethylpropylene amine oxime leucocyte scintigraphy for the diagnosis of bone and joint infections: a retrospective study in 116 patients. Eur J Nucl Med 1995; 22: 302-307.
Contribution of technetium-99m hexamethylpropylene amine oxime labelled leucocyte scintigraphy to the diagnosis of diabetic foot infection.
Devillers A, Moisan A, Hennion F et al. Contribution of technetium-99m hexamethylpropylene amine oxime labelled leucocyte scintigraphy to the diagnosis of diabetic foot infection. Eur J Nucl Med 1998; 25: 132-138.
Becker W, Goldenberg DM, Wolf F. The use of monoclonal antibodies and antibody fragments in the imaging of infectious lesions. Semin Nucl Med 1994; XXIV (2): 142-153.
Becker W, Goldenberg DM, Wolf F. The use of monoclonal antibodies and antibody fragments in the imaging of infectious lesions. Semin Nucl Med 1994; XXIV (2): 142-153.
* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.