메뉴 건너뛰기




Volumn 12, Issue 8, 2000, Pages 428-430

A rare, unreported complication during coronary rotational atherectomy

Author keywords

Rotablator; Rotational atherectomy

Indexed keywords

BIOMATERIAL; POLITEF; VASODILATOR AGENT;

EID: 0034244553     PISSN: 10423931     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (12)
  • 1
    • 0031830803 scopus 로고    scopus 로고
    • Fracture of coronary guide wire during rotational atherectomy with coronary perforation and tamponade
    • Woodfield SL, Lopez A, Heuser RR. Fracture of coronary guide wire during rotational atherectomy with coronary perforation and tamponade. Cathet Cardiovasc Diagn 1998;44:220-223.
    • (1998) Cathet Cardiovasc Diagn , vol.44 , pp. 220-223
    • Woodfield, S.L.1    Lopez, A.2    Heuser, R.R.3
  • 2
    • 0032015869 scopus 로고    scopus 로고
    • Rotablation-induced coronary perforation during management of in-stent restenosis
    • Kaul U, Singh B, Vijan V, et al. Rotablation-induced coronary perforation during management of in-stent restenosis. Indian Heart J 1998;50:203-205.
    • (1998) Indian Heart J , vol.50 , pp. 203-205
    • Kaul, U.1    Singh, B.2    Vijan, V.3
  • 3
    • 0031787763 scopus 로고    scopus 로고
    • Repair of coronary artery perforation after rotastenting by implantation of the Jo-Stent covered stent
    • Ramsdale DR, Mushahwar SS, Morris JL. Repair of coronary artery perforation after rotastenting by implantation of the Jo-Stent covered stent. Cathet Cardiovasc Diagn 1998;45:310-313.
    • (1998) Cathet Cardiovasc Diagn , vol.45 , pp. 310-313
    • Ramsdale, D.R.1    Mushahwar, S.S.2    Morris, J.L.3
  • 4
    • 0030333177 scopus 로고    scopus 로고
    • Coronary perforation complicating rotational ablation: The U.S. multi-center experience
    • Cohen BM, Weber VJ, Relsman M, et al. Coronary perforation complicating rotational ablation: The U.S. multi-center experience. Cathet Cardiovasc Diagn 1996;3(Suppl 3):55-59.
    • (1996) Cathet Cardiovasc Diagn , vol.3 , Issue.3 SUPPL. , pp. 55-59
    • Cohen, B.M.1    Weber, V.J.2    Relsman, M.3
  • 5
    • 0030589263 scopus 로고    scopus 로고
    • Incidence, predictors, and consequences of coronary dissection following high-speed rotational atherectomy
    • Brown DL, Buchbinder M. Incidence, predictors, and consequences of coronary dissection following high-speed rotational atherectomy. Am J Cardiol 1996;78:1416-1419.
    • (1996) Am J Cardiol , vol.78 , pp. 1416-1419
    • Brown, D.L.1    Buchbinder, M.2
  • 6
    • 0029005722 scopus 로고
    • Right ventricular infarction following percutaneous coronary rotational atherectomy
    • Hetterich FS, McEniery PT. Right ventricular infarction following percutaneous coronary rotational atherectomy. Cathet Cardiovasc Diagn 1995;34:321-324.
    • (1995) Cathet Cardiovasc Diagn , vol.34 , pp. 321-324
    • Hetterich, F.S.1    McEniery, P.T.2
  • 7
    • 0030055078 scopus 로고    scopus 로고
    • Fatal coronary embolization following high-speed rotational atherectomy
    • Duong van Huyen JP, Fomes P, Iliou MC, et al. Fatal coronary embolization following high-speed rotational atherectomy. Histopathology 1996;29:73-76.
    • (1996) Histopathology , vol.29 , pp. 73-76
    • Van Duong Huyen, J.P.1    Fomes, P.2    Iliou, M.C.3
  • 8
    • 0030755421 scopus 로고    scopus 로고
    • Risk factors for the development of slow flow during rotational coronary atherectomy
    • Sharma SK, Dangas G, Mehran R, et al. Risk factors for the development of slow flow during rotational coronary atherectomy. Am J Cardiol 1997;80:219-222.
    • (1997) Am J Cardiol , vol.80 , pp. 219-222
    • Sharma, S.K.1    Dangas, G.2    Mehran, R.3
  • 10
    • 0029016755 scopus 로고
    • Guidewire transection during rotational coronary atherectomy due to guide catheter dislodgement and wire kinking
    • Foster-Smith K, Garratt KN, Holmes DR Jr. Guidewire transection during rotational coronary atherectomy due to guide catheter dislodgement and wire kinking. Cathet Cardiovasc Diagn 1995;35:224-227.
    • (1995) Cathet Cardiovasc Diagn , vol.35 , pp. 224-227
    • Foster-Smith, K.1    Garratt, K.N.2    Holmes Jr., D.R.3
  • 11
    • 0030332785 scopus 로고    scopus 로고
    • High-speed rotational atherectomy of tortuous coronary arteries with guidewire-associated pseudostenosis
    • Bowling LS, Guarneri E, Schatz RA, Teirstein PS. High-speed rotational atherectomy of tortuous coronary arteries with guidewire-associated pseudostenosis. Cathet Cardiovasc Diagn 1996;3(Suppl 3):82-84.
    • (1996) Cathet Cardiovasc Diagn , vol.3 , Issue.3 SUPPL. , pp. 82-84
    • Bowling, L.S.1    Guarneri, E.2    Schatz, R.A.3    Teirstein, P.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.