메뉴 건너뛰기




Volumn 8, Issue 5, 2000, Pages 392-398

Precision and accuracy of dual-energy X-ray absorptiometry for determining in vivo body composition of mice

Author keywords

Bone mineral density; Dual energy x ray absorptiometry; DXA; Fat mass

Indexed keywords

ADIPOSE TISSUE; ANIMAL; ARTICLE; BODY COMPOSITION; BONE; BONE DENSITY; C57BL MOUSE; CHEMISTRY; MALE; METHODOLOGY; MOUSE; RADIODENSITOMETRY; RADIOGRAPHY; REPRODUCIBILITY;

EID: 0034242440     PISSN: 10717323     EISSN: None     Source Type: Journal    
DOI: 10.1038/oby.2000.47     Document Type: Article
Times cited : (257)

References (14)
  • 1
    • 0031664399 scopus 로고    scopus 로고
    • Evaluation of dual-energy X-ray absorptiometry for body-composition assessment in rats
    • Bertin E, Ruiz J-C, Mourot J, Peiniau P, Portha B. Evaluation of dual-energy X-ray absorptiometry for body-composition assessment in rats. J Nutr. 1998;128:1550-4.
    • (1998) J Nutr. , vol.128 , pp. 1550-1554
    • Bertin, E.1    Ruiz, J.-C.2    Mourot, J.3    Peiniau, P.4    Portha, B.5
  • 2
    • 0031892464 scopus 로고    scopus 로고
    • Whole body composition of rats determined by dual energy X-ray absorptiometry is correlated with chemical analysis
    • Rose BS, Flatt WP, Martin RJ, Lewis RD. Whole body composition of rats determined by dual energy X-ray absorptiometry is correlated with chemical analysis. J Nutr. 1998; 128:246-50.
    • (1998) J Nutr. , vol.128 , pp. 246-250
    • Rose, B.S.1    Flatt, W.P.2    Martin, R.J.3    Lewis, R.D.4
  • 3
    • 0029990567 scopus 로고    scopus 로고
    • Dual-energy X-ray absorptiometry for the measurement of gross body composition in rats
    • Jebb SA, Garland SW, Jennings G, Elia M. Dual-energy X-ray absorptiometry for the measurement of gross body composition in rats. Br J Nutr. 1996;75:803-9.
    • (1996) Br J Nutr. , vol.75 , pp. 803-809
    • Jebb, S.A.1    Garland, S.W.2    Jennings, G.3    Elia, M.4
  • 4
    • 0000076488 scopus 로고
    • The effect of apparatus, extraction time, and solvent type on lipid extractions of snow geese
    • Dobush GR, Ankey CD, Krementz DG. The effect of apparatus, extraction time, and solvent type on lipid extractions of snow geese. Can J Zool. 1985;63:1917-20.
    • (1985) Can J Zool. , vol.63 , pp. 1917-1920
    • Dobush, G.R.1    Ankey, C.D.2    Krementz, D.G.3
  • 5
    • 0002317811 scopus 로고    scopus 로고
    • Dual energy X-ray absorptiometry
    • Roche AF, Heymsfield SB, Lohman TG, eds. Champaign, IL: Human Kinetics
    • Lohman TG. Dual energy X-ray absorptiometry. In: Roche AF, Heymsfield SB, Lohman TG, eds. Human Body Composition. Champaign, IL: Human Kinetics; 1996, pp.63-78.
    • (1996) Human Body Composition , pp. 63-78
    • Lohman, T.G.1
  • 7
    • 0030028417 scopus 로고    scopus 로고
    • The use of dual-energy X-ray absorptiometry in animals
    • Grier SJ, Turner AS, Alvis MR. The use of dual-energy X-ray absorptiometry in animals. Investig Radiol. 1996;31: 50-62.
    • (1996) Investig Radiol. , vol.31 , pp. 50-62
    • Grier, S.J.1    Turner, A.S.2    Alvis, M.R.3
  • 8
    • 0027225470 scopus 로고
    • Accuracy of measurements of body composition by dual-energy x-ray absorptiometry in vivo
    • Svendsen OL, Haarbo J, Hassager C, Christiansen C. Accuracy of measurements of body composition by dual-energy x-ray absorptiometry in vivo. Am J Clin Nutr. 1993; 57:605-8.
    • (1993) Am J Clin Nutr. , vol.57 , pp. 605-608
    • Svendsen, O.L.1    Haarbo, J.2    Hassager, C.3    Christiansen, C.4
  • 9
    • 0030934978 scopus 로고    scopus 로고
    • Improvement in the accuracy of dual energy x-ray absorptiometry for whole body and regional analysis of body composition: Validation using piglets and methodologic considerations in infants
    • Brunton JA, Weiler HA, Atkinson SA. Improvement in the accuracy of dual energy x-ray absorptiometry for whole body and regional analysis of body composition: validation using piglets and methodologic considerations in infants. Pediatr Res. 1997;41:590-6.
    • (1997) Pediatr Res. , vol.41 , pp. 590-596
    • Brunton, J.A.1    Weiler, H.A.2    Atkinson, S.A.3
  • 10
    • 0032748023 scopus 로고    scopus 로고
    • Increased cortical bone mineral content but unchanged trabecular bone mineral density in female ERβ-1-mice
    • Windahl SH, Vidal O, Andersson G, Gustafsson JA, Ohlsson C. Increased cortical bone mineral content but unchanged trabecular bone mineral density in female ERβ-1-mice. J Clin Inv. 1999;104:895-901.
    • (1999) J Clin Inv. , vol.104 , pp. 895-901
    • Windahl, S.H.1    Vidal, O.2    Andersson, G.3    Gustafsson, J.A.4    Ohlsson, C.5
  • 11
    • 0031454382 scopus 로고    scopus 로고
    • Precision and accuracy of total body bone mass and body composition measurements in the rat using x-ray-based dual photon absorptiometry
    • Makan S, Bayley HS, Webber CE. Precision and accuracy of total body bone mass and body composition measurements in the rat using x-ray-based dual photon absorptiometry. Can J Physiol Pharmacol. 1997;75:1257-61.
    • (1997) Can J Physiol Pharmacol. , vol.75 , pp. 1257-1261
    • Makan, S.1    Bayley, H.S.2    Webber, C.E.3
  • 12
    • 0001049153 scopus 로고
    • Studies on body composition. I. The determination of total body fat by means of the body specific gravity
    • Rathbun EN, Pace N. Studies on body composition. I. The determination of total body fat by means of the body specific gravity. J Biol Chem. 1945;158:667-76.
    • (1945) J Biol Chem. , vol.158 , pp. 667-676
    • Rathbun, E.N.1    Pace, N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.