메뉴 건너뛰기




Volumn 20, Issue 4, 2000, Pages 1169-1177

Improvement in detection of pulmonary nodules: Digital image processing and computeraided diagnosis

Author keywords

Computers, diagnostic aid; Lung neoplasms, diagnosis, 60.30; Lung, nodule, 60.281; Radiography, digital, 60.1215; Subtraction, digital, 60.1215; Subtraction, dual energy, 60.1299

Indexed keywords

ARTICLE; COMPUTER ASSISTED DIAGNOSIS; COMPUTER ASSISTED TOMOGRAPHY; HUMAN; IMAGE PROCESSING; IMAGE QUALITY; IMAGE SUBTRACTION; LUNG COIN LESION; LUNG TUMOR; METHODOLOGY; RADIOGRAPHY; THORAX RADIOGRAPHY;

EID: 0034222271     PISSN: 02715333     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiographics.20.4.g00jl211169     Document Type: Article
Times cited : (36)

References (6)
  • 1
    • 0020606057 scopus 로고
    • Lung cancer detected during a screening program using 4-month chest radiographs
    • Muhm JR, Miller WE, Fontana RS, et al. Lung cancer detected during a screening program using 4-month chest radiographs. Radiology 1983; 148:609-615.
    • (1983) Radiology , vol.148 , pp. 609-615
    • Muhm, J.R.1    Miller, W.E.2    Fontana, R.S.3
  • 2
    • 0026513806 scopus 로고
    • Missed bronchogenic carcinoma: Radiographic findings in 27 patients with a potentially resectable lesion evident in retrospect
    • Austin JHM, Romney BM, Goldsmith LS. Missed bronchogenic carcinoma: radiographic findings in 27 patients with a potentially resectable lesion evident in retrospect. Radiology 1992; 182:115-122.
    • (1992) Radiology , vol.182 , pp. 115-122
    • Austin, J.H.M.1    Romney, B.M.2    Goldsmith, L.S.3
  • 3
    • 0033542870 scopus 로고    scopus 로고
    • Early lung cancer action project: Overall design and findings from baseline screening
    • Henschke CI, McCauley DI, Yankelevitz DF, et al. Early lung cancer action project: overall design and findings from baseline screening. Lancet 1999; 354:99-105.
    • (1999) Lancet , vol.354 , pp. 99-105
    • Henschke, C.I.1    McCauley, D.I.2    Yankelevitz, D.F.3
  • 4
    • 0031054539 scopus 로고    scopus 로고
    • Dual-energy radiography
    • Hartman TE. Dual-energy radiography. Semin Roentgenol 1997; 32:45-49.
    • (1997) Semin Roentgenol , vol.32 , pp. 45-49
    • Hartman, T.E.1
  • 5
    • 0028873150 scopus 로고
    • Clinical evaluation of pulmonary nodules with single-exposure dual-energy subtraction chest radiography with an iterative noise-reduction algorithm
    • Kido S, Ikezoe J, Naito H, et al. Clinical evaluation of pulmonary nodules with single-exposure dual-energy subtraction chest radiography with an iterative noise-reduction algorithm. Radiology 1995; 194:407-412.
    • (1995) Radiology , vol.194 , pp. 407-412
    • Kido, S.1    Ikezoe, J.2    Naito, H.3
  • 6
    • 0007842537 scopus 로고    scopus 로고
    • Dual-energy subtraction computed chest radiography: Comparison of diagnostic accuracy with conventional computed radiography
    • MacMahon H, Cannon W, Engelmann RM, Carlin M, Doi K. Dual-energy subtraction computed chest radiography: comparison of diagnostic accuracy with conventional computed radiography (abstr). Radiology 1998; 209(P):544.
    • (1998) Radiology , vol.209 , Issue.P , pp. 544
    • MacMahon, H.1    Cannon, W.2    Engelmann, R.M.3    Carlin, M.4    Doi, K.5