메뉴 건너뛰기




Volumn 84, Issue 1, 2000, Pages 22-26

Magnetically connected removable sectional denture for a maxillary defect with severe undercut: A clinical report

Author keywords

[No Author keywords available]

Indexed keywords

COBALT; DENTAL ALLOY; SAMARIUM;

EID: 0034219354     PISSN: 00223913     EISSN: None     Source Type: Journal    
DOI: 10.1067/mpr.2000.107916     Document Type: Article
Times cited : (30)

References (23)
  • 1
    • 0013357561 scopus 로고
    • Magnets to stabilize dentures
    • Freedman H. Magnets to stabilize dentures. J Am Dent Assoc 1953; 47:288-97.
    • (1953) J Am Dent Assoc , vol.47 , pp. 288-297
    • Freedman, H.1
  • 2
    • 0008299846 scopus 로고
    • Maxillofacial prosthesis with magnetic stabilizers
    • Nadeau J. Maxillofacial prosthesis with magnetic stabilizers. J Prosthet Dent 1956;6:114-9.
    • (1956) J Prosthet Dent , vol.6 , pp. 114-119
    • Nadeau, J.1
  • 3
    • 0008337548 scopus 로고
    • Magnets for the retention of a sectional intraoral prosthesis a case history
    • Robinson JE. Magnets for the retention of a sectional intraoral prosthesis A case history. J Prosthet Dent 1963;13:1167-71.
    • (1963) J Prosthet Dent , vol.13 , pp. 1167-1171
    • Robinson, J.E.1
  • 4
    • 0015029385 scopus 로고
    • The use of magnets in a maxillofacial prosthesis
    • Javid N. The use of magnets in a maxillofacial prosthesis. J Prosthet Dent 1971;25:334-41.
    • (1971) J Prosthet Dent , vol.25 , pp. 334-341
    • Javid, N.1
  • 5
    • 0017222375 scopus 로고
    • A magnetically retained interim maxillary obturator
    • Federick DR. A magnetically retained interim maxillary obturator. J Prosthet Dent 1976;36:671-5.
    • (1976) J Prosthet Dent , vol.36 , pp. 671-675
    • Federick, D.R.1
  • 7
    • 0020105125 scopus 로고
    • Combined magnetic plus rod and tube retention in sectional denture
    • Ling BC. Combined magnetic plus rod and tube retention in sectional denture. J Dent 1982;10:7-11.
    • (1982) J Dent , vol.10 , pp. 7-11
    • Ling, B.C.1
  • 9
    • 0021490605 scopus 로고
    • Magnetic denture retention systems: Inexpensive and efficient
    • Gillings BR. Magnetic denture retention systems: inexpensive and efficient. Int Dent J 1984;34:184-97.
    • (1984) Int Dent J , vol.34 , pp. 184-197
    • Gillings, B.R.1
  • 10
    • 0025499267 scopus 로고
    • Use of a sectional prosthesis following partial maxillary resection, clinical report
    • Masumi S, Miyake S, Kido H, Toyoda S. Use of a sectional prosthesis following partial maxillary resection, clinical report. J Prosthet Dent 1990;64:401-3.
    • (1990) J Prosthet Dent , vol.64 , pp. 401-403
    • Masumi, S.1    Miyake, S.2    Kido, H.3    Toyoda, S.4
  • 11
    • 0025986264 scopus 로고
    • The direct and indirect techniques of making magnetically retained overdentures
    • Wang NH, von der Lehr WN. The direct and indirect techniques of making magnetically retained overdentures. J Prosthet Dent 1991;65:112-7.
    • (1991) J Prosthet Dent , vol.65 , pp. 112-117
    • Wang, N.H.1    Von Der Lehr, W.N.2
  • 12
    • 0348129254 scopus 로고
    • Clinical application of dental magnetic attachment for partial denture - Construction of upper removable partial denture without clasp
    • Masumi S, Ozamoto M, Arita M, Takeya K, Mihara T, Kondo T, et al. Clinical application of dental magnetic attachment for partial denture - construction of upper removable partial denture without clasp. J Kyushu Dent Soc 1995;49:539-45.
    • (1995) J Kyushu Dent Soc , vol.49 , pp. 539-545
    • Masumi, S.1    Ozamoto, M.2    Arita, M.3    Takeya, K.4    Mihara, T.5    Kondo, T.6
  • 13
    • 0029243661 scopus 로고
    • Freestanding magnetic retention for extraoral prosthesis with osseointegrated implants
    • Thomas KF. Freestanding magnetic retention for extraoral prosthesis with osseointegrated implants. J Prosthet Dent 1995;73:162-5.
    • (1995) J Prosthet Dent , vol.73 , pp. 162-165
    • Thomas, K.F.1
  • 14
    • 0030227461 scopus 로고    scopus 로고
    • Obturator prosthesis retention for edentulous patients with large palatal defects: A clinical report
    • Antoniou DV, Toljanic JA, Graham L. Obturator prosthesis retention for edentulous patients with large palatal defects: a clinical report. J Prosthet Dent 1996;76:227-9.
    • (1996) J Prosthet Dent , vol.76 , pp. 227-229
    • Antoniou, D.V.1    Toljanic, J.A.2    Graham, L.3
  • 15
    • 0029678430 scopus 로고    scopus 로고
    • Technique for magnetic placement and orientation of a facial prosthesis
    • Lemon JC, Chambers MS, Wesley PJ, Martin JW. Technique for magnetic placement and orientation of a facial prosthesis. J Prosthet Dent 1996; 75:50-2.
    • (1996) J Prosthet Dent , vol.75 , pp. 50-52
    • Lemon, J.C.1    Chambers, M.S.2    Wesley, P.J.3    Martin, J.W.4
  • 16
    • 0031255595 scopus 로고    scopus 로고
    • Minimizing prosthesis movement in a midfacial defect: A clinical report
    • Dumbrigue HB, Fyler A. Minimizing prosthesis movement in a midfacial defect: a clinical report. J Prosthet Dent 1997;78:341-5.
    • (1997) J Prosthet Dent , vol.78 , pp. 341-345
    • Dumbrigue, H.B.1    Fyler, A.2
  • 17
    • 0031228864 scopus 로고    scopus 로고
    • Sectional prosthesis for total maxillectomy patients: A clinical report
    • Wang RR. Sectional prosthesis for total maxillectomy patients: a clinical report. J Prosthet Dent 1997;78:241-4.
    • (1997) J Prosthet Dent , vol.78 , pp. 241-244
    • Wang, R.R.1
  • 18
    • 0032113602 scopus 로고    scopus 로고
    • Palatal augmentation prosthesis with alternative palatal vaults for speech and swallowing: A clinical report
    • Shimodaira K, Yoshida H, Yusa H, Kanazawa T. Palatal augmentation prosthesis with alternative palatal vaults for speech and swallowing: a clinical report. J Prosthet Dent 1998;80:1-3.
    • (1998) J Prosthet Dent , vol.80 , pp. 1-3
    • Shimodaira, K.1    Yoshida, H.2    Yusa, H.3    Kanazawa, T.4
  • 19
    • 0022747545 scopus 로고
    • Retentive characteristics of different magnetic systems for dental applications
    • Highton R, Caputo AA, Pezzoli M, Matyas J. Retentive characteristics of different magnetic systems for dental applications. J Prosthet Dent 1986; 56:104-6.
    • (1986) J Prosthet Dent , vol.56 , pp. 104-106
    • Highton, R.1    Caputo, A.A.2    Pezzoli, M.3    Matyas, J.4
  • 21
    • 0026232459 scopus 로고
    • The effects of sodium fluoride and stannous fluoride on the surface roughness of intraoral magnet systems
    • Obatake RM, Collard SM, Martin J, Ladd GD. The effects of sodium fluoride and stannous fluoride on the surface roughness of intraoral magnet systems. J Prosthet Dent 1991;66:553-8.
    • (1991) J Prosthet Dent , vol.66 , pp. 553-558
    • Obatake, R.M.1    Collard, S.M.2    Martin, J.3    Ladd, G.D.4
  • 22
    • 0029384499 scopus 로고
    • Retentive characteristics of different dental magnetic systems
    • Akaltan F, Can G. Retentive characteristics of different dental magnetic systems. J Prosthet Dent 1995;74:422-7.
    • (1995) J Prosthet Dent , vol.74 , pp. 422-427
    • Akaltan, F.1    Can, G.2
  • 23
    • 0031138288 scopus 로고    scopus 로고
    • Effect of acidic primers on bonding between stainless steel and auto-polymerizing methacrylic resins
    • Matsumura H, Tanaka T, Atsuta M. Effect of acidic primers on bonding between stainless steel and auto-polymerizing methacrylic resins. J Dent 1997;25:285-90.
    • (1997) J Dent , vol.25 , pp. 285-290
    • Matsumura, H.1    Tanaka, T.2    Atsuta, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.