메뉴 건너뛰기




Volumn 18, Issue 3, 2000, Pages 494-499

Biological and mechanical characteristics of the interface between a new swelling anchor and bone

Author keywords

[No Author keywords available]

Indexed keywords

BONE; COPOLYMERS; ENERGY DISPERSIVE SPECTROSCOPY; IMPLANTS (SURGICAL); INTERFACES (MATERIALS); LIVING SYSTEMS STUDIES; LOAD TESTING; SCANNING ELECTRON MICROSCOPY; SWELLING;

EID: 0034190269     PISSN: 07360266     EISSN: None     Source Type: Journal    
DOI: 10.1002/jor.1100180324     Document Type: Article
Times cited : (9)

References (21)
  • 1
    • 0031550188 scopus 로고    scopus 로고
    • Synthesis and characterization of poly(MMA‐AA) copolymer for bioimplant applications
    • 1 Abusafieh A, Gobran R, Kalidindi SR: Synthesis and characterization of poly(MMA‐AA) copolymer for bioimplant applications. J Appl Polymer Sci 63: 75–87, 1997
    • (1997) J Appl Polymer Sci , vol.63 , pp. 75-87
    • Abusafieh, A1    Gobran, R2    Kalidindi, SR3
  • 2
    • 0031543388 scopus 로고    scopus 로고
    • Development of self‐anchoring bone implants. I. Processing and material characterization
    • 2 Abusafich A, Siegler S, Kalidindi SR: Development of self‐anchoring bone implants. I. Processing and material characterization. J Biomed Mater Res 38: 314–327, 1997
    • (1997) J Biomed Mater Res , vol.38 , pp. 314-327
    • Abusafich, A1    Siegler, S2    Kalidindi, SR3
  • 5
    • 0027182808 scopus 로고
    • Compression strength of donor bone for posterior lumbar interbody fusion
    • 5 Brantigan JW, Cunningham BW, Warden K, McAfee PC, Steffee AD: Compression strength of donor bone for posterior lumbar interbody fusion. Spine 18: 1213–1221, 1993
    • (1993) Spine , vol.18 , pp. 1213-1221
    • Brantigan, JW1    Cunningham, BW2    Warden, K3    McAfee, PC4    Steffee, AD5
  • 6
    • 0028954390 scopus 로고
    • The Deadman theory of suture anchors: observations along a south Texas fence line
    • 6 Burkhart SS: The Deadman theory of suture anchors: observations along a south Texas fence line. J Arthrosc Rel Surg 11: 119–123, 1995
    • (1995) J Arthrosc Rel Surg , vol.11 , pp. 119-123
    • Burkhart, SS1
  • 8
    • 0017698252 scopus 로고
    • The compressive behavior of bone as a two‐phase porous structure
    • 8 Carter DR, Hayes WC: The compressive behavior of bone as a two‐phase porous structure. J Bone Joint Surg [Am] 59: 7: 954–962, 1977
    • (1977) J Bone Joint Surg [Am] , vol.59 , Issue.7 , pp. 954-962
    • Carter, DR1    Hayes, WC2
  • 10
    • 0028198577 scopus 로고
    • The development of suture anchors for use in soft tissue fixation to bone
    • 10 Goble EM, Somers WK, Clark R, Olsen RE: The development of suture anchors for use in soft tissue fixation to bone. Am J Sports Med 22: 236–239, 1994
    • (1994) Am J Sports Med , vol.22 , pp. 236-239
    • Goble, EM1    Somers, WK2    Clark, R3    Olsen, RE4
  • 11
    • 0018034866 scopus 로고
    • Stimulation of bone formation by a swelling endosseous implant
    • 11 Greenberg AR, Kamel IL, Dubin S, Miller A: Stimulation of bone formation by a swelling endosseous implant. J Biomed Mater Res 12: 929–933, 1978
    • (1978) J Biomed Mater Res , vol.12 , pp. 929-933
    • Greenberg, AR1    Kamel, IL2    Dubin, S3    Miller, A4
  • 12
    • 85120588180 scopus 로고
    • Contemporary Contact Lens Practice
    • 12 Harstein J, Swanson KV, Harris CR: Contemporary Contact Lens Practice, pp 89–91. 150–153. St. Louis, Mosby‐Year Book, 1991
    • (1991) , pp. 89-91
    • Harstein, J1    Swanson, KV2    Harris, CR3
  • 13
    • 0025081586 scopus 로고
    • Biomechanical and histological evaluation of the Herbert screw
    • 13 Lange RH, Vanderby R Jr, Engber WD, Glad RW, Purnell ML: Biomechanical and histological evaluation of the Herbert screw. J Orthop Trauma 4: 275–282, 1990
    • (1990) J Orthop Trauma , vol.4 , pp. 275-282
    • Lange, RH1    Vanderby, R2    Engber, WD3    Glad, RW4    Purnell, ML5
  • 14
    • 0027351322 scopus 로고
    • The holding strength of cannulated screws compared with solid core screws in cortical and cancellous bone
    • 14 Leggon R, Lindsey RW, Doherty BJ, Alexander J, Noble P: The holding strength of cannulated screws compared with solid core screws in cortical and cancellous bone. J Orthop Trauma 7: 450–457, 1993
    • (1993) J Orthop Trauma , vol.7 , pp. 450-457
    • Leggon, R1    Lindsey, RW2    Doherty, BJ3    Alexander, J4    Noble, P5
  • 15
    • 0026452569 scopus 로고
    • Orthopedic prosthesis fixation
    • 15 Park JB: Orthopedic prosthesis fixation. Ann Biomed Eng 20: 583–594, 1992
    • (1992) Ann Biomed Eng , vol.20 , pp. 583-594
    • Park, JB1
  • 16
    • 0018762030 scopus 로고
    • Physical and biological aspects of fracture healing with special reference to internal fixation
    • 16 Perren SM: Physical and biological aspects of fracture healing with special reference to internal fixation. Clin Orthop 138: 175–196, 1979
    • (1979) Clin Orthop , vol.138 , pp. 175-196
    • Perren, SM1
  • 17
    • 0031006780 scopus 로고    scopus 로고
    • A biomechanical evaluation of suture anchors in repair of the rotator cuff
    • 17 Rossouw DJ, McElroy BJ, Amis AA, Emery RJ: A biomechanical evaluation of suture anchors in repair of the rotator cuff. J Bone Joint Surg [Br] 79: 458–461, 1997
    • (1997) J Bone Joint Surg [Br] , vol.79 , pp. 458-461
    • Rossouw, DJ1    McElroy, BJ2    Amis, AA3    Emery, RJ4
  • 18
    • 0029896649 scopus 로고    scopus 로고
    • Dimerization of tear lysozyme on hydrophilic contact lens polymers
    • 18 Scott G, Mowrey‐Mckee M: Dimerization of tear lysozyme on hydrophilic contact lens polymers. Curr Eye Res 15: 461–466, 1996
    • (1996) Curr Eye Res , vol.15 , pp. 461-466
    • Scott, G1    Mowrey‐Mckee, M2
  • 19
    • 85120592255 scopus 로고
    • 19 Somers WK, Goble ME: Suture Anchor Assembly. U.S. Patent No. 4,632,100, December 30, 1986
    • (1986)
    • Somers, WK1    Goble, ME2
  • 20
    • 0002289260 scopus 로고
    • Bone ingrowth into porous polymers., in: Biocompatibility of Orthopaedic Implants
    • 20 Spector M: Bone ingrowth into porous polymers. In: Biocompatibility of Orthopaedic Implants, vol 2, pp 89–128. Ed by DF Williams. Boca Raton, Florid, CRC Press, 1982
    • (1982) , vol.2 , pp. 89-128
    • Spector, M1
  • 21
    • 0031543427 scopus 로고    scopus 로고
    • Development of self‐anchoring bone implants. II. Bone‐implant interface characteristics in vitro
    • 21 Vemuganti A, Siegler S, Abusafieh A, Kalidindi S: Development of self‐anchoring bone implants. II. Bone‐implant interface characteristics in vitro. J Biomed Mater Res 38: 328–336, 1997
    • (1997) J Biomed Mater Res , vol.38 , pp. 328-336
    • Vemuganti, A1    Siegler, S2    Abusafieh, A3    Kalidindi, S4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.