메뉴 건너뛰기




Volumn 216, Issue 5, 2000, Pages 324-326

Measurement of eye length and eye shape by optical low coherence reflectometry;Messung der augenlange und augenform mittels optischer kurzkoharenz- reflektometrie

Author keywords

Eye growth; Eye length; Eye shape; Myopia; Optical low coherence reflectometry

Indexed keywords

ARTICLE; EYE AXIS LENGTH; EYE DEVELOPMENT; HUMAN; HUMAN EXPERIMENT; MEASUREMENT; MYOPIA; NORMAL HUMAN; OPTICAL INSTRUMENTATION; REFLECTOMETRY; EYE; EYE MALFORMATION; EYE REFRACTION; GROWTH, DEVELOPMENT AND AGING; INSTRUMENTATION; OPTOMETRY; PATHOLOGY; PATHOPHYSIOLOGY;

EID: 0034185813     PISSN: 00232165     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2000-10574     Document Type: Article
Times cited : (4)

References (12)
  • 2
    • 0015983830 scopus 로고
    • Refraction of the periphery of the eye
    • Millodot M, Lamont A. Refraction of the periphery of the eye. J Opt Soc Am 1974; 64(1): 110-111
    • (1974) J Opt Soc Am , vol.64 , Issue.1 , pp. 110-111
    • Millodot, M.1    Lamont, A.2
  • 7
    • 84975538971 scopus 로고
    • Eye-length measurement by interferometry with partially coherent light
    • Fercher AF, Mengedoth K, Werner W. Eye-length measurement by interferometry with partially coherent light. Opt Lett 1988; 13: 1867-1869
    • (1988) Opt Lett , vol.13 , pp. 1867-1869
    • Fercher, A.F.1    Mengedoth, K.2    Werner, W.3
  • 8
    • 0026101781 scopus 로고
    • Optical measurement of the axial length by laser Doppler interferometry
    • Hitzenberger CK. Optical measurement of the axial length by laser Doppler interferometry. Invest Ophthalmol Vis Sci 1991; 32: 616-624
    • (1991) Invest Ophthalmol Vis Sci , vol.32 , pp. 616-624
    • Hitzenberger, C.K.1
  • 9
    • 0000276665 scopus 로고    scopus 로고
    • Measurement of intraocular distances in humans and chicks with a precision of better than ±20 μm by laser Doppler interferometry
    • Schmid GF, Petrig BL, Riva CE, Shin KH, Stone RA, Mendel MJ, Laties AM. Measurement of intraocular distances in humans and chicks with a precision of better than ±20 μm by laser Doppler interferometry. Applied Optics 1996; 35 (19): 3358-3361
    • (1996) Applied Optics , vol.35 , Issue.19 , pp. 3358-3361
    • Schmid, G.F.1    Petrig, B.L.2    Riva, C.E.3    Shin, K.H.4    Stone, R.A.5    Mendel, M.J.6    Laties, A.M.7
  • 12
    • 0004328117 scopus 로고
    • New York, American National Standards Institute
    • American National Standards Institute. Safe use of lasers, ANSI Z 136.1. New York, American National Standards Institute 1986
    • (1986) Safe Use of Lasers, ANSI Z 136.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.