메뉴 건너뛰기




Volumn 39, Issue 5, 2000, Pages 592-604

An experimental analysis of the effect of refrigerant charge level on an automotive refrigeration system

Author keywords

Automotive; Charge; Entropy; Generation; Refrigeration

Indexed keywords


EID: 0034179277     PISSN: 12900729     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1290-0729(00)00208-8     Document Type: Article
Times cited : (26)

References (8)
  • 1
    • 0033745243 scopus 로고    scopus 로고
    • An experimental investigation of cycling losses in an automotive air conditioning system
    • September
    • [1] Ratts E.B., Brown J.S., An experimental investigation of cycling losses in an automotive air conditioning system, Appl. Thermal Engng. (September 2000).
    • (2000) Appl. Thermal Engng.
    • Ratts, E.B.1    Brown, J.S.2
  • 2
    • 0032691687 scopus 로고    scopus 로고
    • Second-law analysis of refrigeration cyclic open systems
    • [2] Meunier F., Second-law analysis of refrigeration cyclic open systems, ASHRAE Trans. 105 (1) (1999) 1267-1273.
    • (1999) ASHRAE Trans. , vol.105 , Issue.1 , pp. 1267-1273
    • Meunier, F.1
  • 3
    • 0032669290 scopus 로고    scopus 로고
    • Second law study of HVAC distribution system performance
    • [3] Franconi E.M., Brandemuehl M.J., Second law study of HVAC distribution system performance, ASHRAE Trans. 105 (1) (1999) 1237-1246.
    • (1999) ASHRAE Trans. , vol.105 , Issue.1 , pp. 1237-1246
    • Franconi, E.M.1    Brandemuehl, M.J.2
  • 4
    • 0027974659 scopus 로고
    • Second-law analysis of vapor compression heat pumps with solution circuit
    • [4] Amrane K., Radermacher R., Second-law analysis of vapor compression heat pumps with solution circuit, J. Engrg. Gas Turbines Power 116 (1994) 453-461.
    • (1994) J. Engrg. Gas Turbines Power , vol.116 , pp. 453-461
    • Amrane, K.1    Radermacher, R.2
  • 5
    • 0028699887 scopus 로고
    • Relationships between irreversibility, exergy destruction, and entropy generation for systems and components
    • [5] Krakow K.I., Relationships between irreversibility, exergy destruction, and entropy generation for systems and components, ASHRAE Trans. 100 (1) (1994) 3-10.
    • (1994) ASHRAE Trans. , vol.100 , Issue.1 , pp. 3-10
    • Krakow, K.I.1
  • 6
    • 0029700604 scopus 로고    scopus 로고
    • Cycling and quasi-steady behavior of a refrigerator
    • [6] Krause P.E., Bullard C.W., Cycling and quasi-steady behavior of a refrigerator, ASHRAE Trans. 102 (1) (1996) 1061-1070.
    • (1996) ASHRAE Trans. , vol.102 , Issue.1 , pp. 1061-1070
    • Krause, P.E.1    Bullard, C.W.2
  • 7
    • 0030707212 scopus 로고    scopus 로고
    • An experimental analysis of cycling losses in domestic refrigerator-freezers
    • [7] Coulter W.H., Bullard C.W., An experimental analysis of cycling losses in domestic refrigerator-freezers, ASHRAE Trans. 103 (1) (1997) 587-596.
    • (1997) ASHRAE Trans. , vol.103 , Issue.1 , pp. 587-596
    • Coulter, W.H.1    Bullard, C.W.2
  • 8
    • 0004241756 scopus 로고
    • Catt: Computer-aided thermodynamic tables
    • Van Wylen G.J., Sonntag R.E., Borgnakke C.
    • [8] Intellipro, Inc., CATT: Computer-Aided Thermodynamic Tables, in: Van Wylen G.J., Sonntag R.E., Borgnakke C., Fundamentals of Classical Thermodynamics, 4th Edition, 1994.
    • (1994) Fundamentals of Classical Thermodynamics, 4th Edition