Volumn 7, Issue 2, 2000, Pages 71-78

A comparison between cemented, press-fit, and HA-coated interfaces in Kinemax total knee replacement

Author keywords

Fixation; Hydroxyapatite; Press fit; Total knee replacement

Indexed keywords

CEMENT; HYDROXYAPATITE;

EID: 0034177468     PISSN: 09680160     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0968-0160(99)00041-1     Document Type: Article
Times cited : (4)

References (16)
  • 1
    • 0029056371 scopus 로고
    • Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses
    • Ryd L., Albrektsson B.E., Carlsson L. et al. Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses. J Bone Jt Surg Am Vol. 77A:1995;377-383.
    • (1995) J Bone Jt Surg Am Vol , vol.77 , pp. 377-383
    • Ryd, L.1    Albrektsson, B.E.2    Carlsson, L.3
  • 2
    • 0029062186 scopus 로고
    • Femoral component migration in total knee arthroplasty: Randomized study comparing cemented and uncemented fixation of the Miller-Galante I design
    • Nilsson K.G., Karrholm J., Linder L. Femoral component migration in total knee arthroplasty: randomized study comparing cemented and uncemented fixation of the Miller-Galante I design. J Orthop Res. 13:1995;347-356.
    • (1995) J Orthop Res , vol.13 , pp. 347-356
    • Nilsson, K.G.1    Karrholm, J.2    Linder, L.3
  • 3
    • 0343113465 scopus 로고    scopus 로고
    • Influence of design on the range of motion after total knee arthroplasty
    • S. Niwa, S. Yoshino, M. Kurosawa, K. Shino, & S. Yamamoto. Tokyo: Springer-Verlag
    • Hoshino A. Influence of design on the range of motion after total knee arthroplasty. Niwa S., Yoshino S., Kurosawa M., Shino K., Yamamoto S. Reconstruction of the knee joint. 1997;324-329 Springer-Verlag, Tokyo.
    • (1997) Reconstruction of the Knee Joint , pp. 324-329
    • Hoshino, A.1
  • 4
    • 0031785763 scopus 로고    scopus 로고
    • The effect of hydroxyapatite on the micromotion of total knee prostheses
    • Nellissen R.G.H.H., Valstar E.R., Rozing P.M. The effect of hydroxyapatite on the micromotion of total knee prostheses. J Bone Jt Surg Am Vol. 80A:1998;665-1672.
    • (1998) J Bone Jt Surg Am Vol , vol.80 , pp. 665-1672
    • Nellissen, R.G.H.H.1    Valstar, E.R.2    Rozing, P.M.3
  • 5
    • 0032922332 scopus 로고    scopus 로고
    • Hydroxyapatite coating versus cemented fixation of the tibial component in total knee arthroplasty
    • Nilsson K.G., Karrholm J., Carlsson L., Dalen T. Hydroxyapatite coating versus cemented fixation of the tibial component in total knee arthroplasty. J Arthroplasty. 14:1999;9-20.
    • (1999) J Arthroplasty , vol.14 , pp. 9-20
    • Nilsson, K.G.1    Karrholm, J.2    Carlsson, L.3    Dalen, T.4
  • 7
    • 0025427129 scopus 로고
    • An investigation of a compliant interface for press-fit joint replacement
    • Walker P.S., Rodger R.F., Miegel R.E. et al. An investigation of a compliant interface for press-fit joint replacement. J Orthop Res. 8:1990;453-463.
    • (1990) J Orthop Res , vol.8 , pp. 453-463
    • Walker, P.S.1    Rodger, R.F.2    Miegel, R.E.3
  • 8
    • 0026574556 scopus 로고
    • The press-fit Kinemax knee arthroplasty. High failure rate of non-cemented implants
    • Nafei A., Nielsen S., Kristensen O., Hvid I. The press-fit Kinemax knee arthroplasty. High failure rate of non-cemented implants. J Bone Jt Surg Br Vol. 74B:1992;243-246.
    • (1992) J Bone Jt Surg Br Vol , vol.74 , pp. 243-246
    • Nafei, A.1    Nielsen, S.2    Kristensen, O.3    Hvid, I.4
  • 9
    • 0025042927 scopus 로고
    • A comparative study of uncemented tibial components
    • Walker P.S., Hsu H.-P., Zimmerman R.A. A comparative study of uncemented tibial components. J Arthroplasty. 5:1990;245-253.
    • (1990) J Arthroplasty , vol.5 , pp. 245-253
    • Walker, P.S.1    Hsu, H.-P.2    Zimmerman, R.A.3
  • 10
    • 0031660255 scopus 로고    scopus 로고
    • Patello-femoral complications in symmetrical total knee arthroplasty
    • in press
    • Harwin S.F. Patello-femoral complications in symmetrical total knee arthroplasty. J Arthroplasty 1998 (in press).
    • (1998) J Arthroplasty
    • Harwin, S.F.1
  • 11
    • 0026265927 scopus 로고
    • Design of Kinemax total knee replacement bearing surfaces
    • Walker P.S. Design of Kinemax total knee replacement bearing surfaces. Acta Orthop Belg. 57:1991;108-113.
    • (1991) Acta Orthop Belg , vol.57 , pp. 108-113
    • Walker, P.S.1
  • 12
    • 0026924825 scopus 로고
    • A simplified radiographic method for measuring bone-component motion in total knees
    • Walker P.S., Sathasivam S. A simplified radiographic method for measuring bone-component motion in total knees. J Biomech. 25:1992;1059-1066.
    • (1992) J Biomech , vol.25 , pp. 1059-1066
    • Walker, P.S.1    Sathasivam, S.2
  • 13
    • 0024950083 scopus 로고
    • Rationale of the Knee Society Clinical Rating System
    • Insall J.N., Dorr L.D., Scott R.D., Scott W.N. Rationale of the Knee Society Clinical Rating System. Clin Orthop. 248:1989;13-14.
    • (1989) Clin Orthop , vol.248 , pp. 13-14
    • Insall, J.N.1    Dorr, L.D.2    Scott, R.D.3    Scott, W.N.4
  • 14
    • 0028057161 scopus 로고
    • Surface characteristics following tibial preparation during total knee arthroplasty
    • Toksvig-Larsen S., Ryd L. Surface characteristics following tibial preparation during total knee arthroplasty. J Arthroplasty. 9:1994;63-66.
    • (1994) J Arthroplasty , vol.9 , pp. 63-66
    • Toksvig-Larsen, S.1    Ryd, L.2
  • 15
    • 0022897314 scopus 로고
    • A compliant interface for total knee arthroplasty
    • Miegel R.E., Walker P.S., Nelson P. et al. A compliant interface for total knee arthroplasty. J Orthop Res. 4:1986;486-493.
    • (1986) J Orthop Res , vol.4 , pp. 486-493
    • Miegel, R.E.1    Walker, P.S.2    Nelson, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.