메뉴 건너뛰기




Volumn 47, Issue 1, 2000, Pages 241-245

A modified method of planning and delivery for dynamic multileaf collimator intensity-modulated radiation therapy

Author keywords

Abutment regions; Dose nonuniformity; Field matching; Intensity modulated radiation therapy; Tomotherapy

Indexed keywords

ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DEVICE; LINEAR ACCELERATOR; PHANTOM; PRIORITY JOURNAL; RADIATION DOSE DISTRIBUTION; RADIOTHERAPY; TECHNIQUE; TOMOGRAPHY; TREATMENT PLANNING;

EID: 0034176160     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(99)00557-X     Document Type: Article
Times cited : (5)

References (14)
  • 1
    • 0002204586 scopus 로고    scopus 로고
    • Conformal therapy using a multileaf intensity modulating collimator
    • In: Sternick ES, editor Durango, CO: Advanced Medical Publishing;
    • Curran BH. Conformal therapy using a multileaf intensity modulating collimator. In: Sternick ES, editor. The theory and practice of intensity modulated radiation therapy. Durango, CO: Advanced Medical Publishing; 1997. p.75-90.
    • (1997) The Theory and Practice of Intensity Modulated Radiation Therapy , pp. 75-90
    • Curran, B.H.1
  • 2
    • 0029273303 scopus 로고
    • A system for planning and rotational delivery of intensity-modulated fields
    • Carol M.P. A system for planning and rotational delivery of intensity-modulated fields. Int J Imag Sys Technol. 6:1995;56-61.
    • (1995) Int J Imag Sys Technol , vol.6 , pp. 56-61
    • Carol, M.P.1
  • 3
    • 0032520945 scopus 로고    scopus 로고
    • Phantoms for IMRT dose distribution measurement and treatment verification
    • Low D.A., Gerber R.L., Mutic S., Purdy J.A. Phantoms for IMRT dose distribution measurement and treatment verification. Int J Radiat Oncol Biol Phys. 40:1998;1231-1235.
    • (1998) Int J Radiat Oncol Biol Phys , vol.40 , pp. 1231-1235
    • Low, D.A.1    Gerber, R.L.2    Mutic, S.3    Purdy, J.A.4
  • 4
    • 0001945667 scopus 로고
    • Dose distribution between adjoining therapy fields
    • Lance J.S., Morgan J.E. Dose distribution between adjoining therapy fields. Radiology. 79:1962;24-29.
    • (1962) Radiology , vol.79 , pp. 24-29
    • Lance, J.S.1    Morgan, J.E.2
  • 5
    • 0018413585 scopus 로고
    • A technique for matching orthogonal megavoltage fields
    • Williamson T.J. A technique for matching orthogonal megavoltage fields. Int J Radiat Oncol Biol Phys. 5:1979;111.
    • (1979) Int J Radiat Oncol Biol Phys , vol.5 , pp. 111
    • Williamson, T.J.1
  • 6
    • 0015834161 scopus 로고
    • The matching of adjacent fields in radiotherapy
    • Armstrong D.I., Tait J.J. The matching of adjacent fields in radiotherapy. Radiology. 108:1973;419.
    • (1973) Radiology , vol.108 , pp. 419
    • Armstrong, D.I.1    Tait, J.J.2
  • 7
    • 0017662625 scopus 로고
    • Clinical complications arising from overlapping of adjacent radiation fields: Physical and technical considerations
    • Seymour H., Reid A., Simpson L., Age P.J. Clinical complications arising from overlapping of adjacent radiation fields Physical and technical considerations. Int J Radiat Oncol Biol Phys. 2:1977;801-808.
    • (1977) Int J Radiat Oncol Biol Phys , vol.2 , pp. 801-808
    • Seymour, H.1    Reid, A.2    Simpson, L.3    Age, P.J.4
  • 8
    • 0031929368 scopus 로고    scopus 로고
    • Effects of set-up uncertainties on the dose distribution in the match region of supraclavicular tangential breast fields
    • Idzes M.H.M., Holmberg O., Minjnheer B.J., Huizenga H. Effects of set-up uncertainties on the dose distribution in the match region of supraclavicular tangential breast fields. Radiother Oncol. 46:1998;91-98.
    • (1998) Radiother Oncol , vol.46 , pp. 91-98
    • Idzes, M.H.M.1    Holmberg, O.2    Minjnheer, B.J.3    Huizenga, H.4
  • 12
    • 0032788356 scopus 로고    scopus 로고
    • Abutment region dosimetry for serial tomotherapy
    • Low D.A., Mutic S., et al. Abutment region dosimetry for serial tomotherapy. Int J Radiat Oncol Biol Phys. 45:1999;193-203.
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 193-203
    • Low, D.A.1    Mutic, S.2
  • 13
    • 0030796894 scopus 로고    scopus 로고
    • Abutment region dosimetry for sequential arc IMRT delivery
    • Low D.A., Mutic S. Abutment region dosimetry for sequential arc IMRT delivery. Phys Med Biol. 42:1997;1465-1470.
    • (1997) Phys Med Biol , vol.42 , pp. 1465-1470
    • Low, D.A.1    Mutic, S.2
  • 14
    • 0030457355 scopus 로고    scopus 로고
    • Evaluation of dose algorithm of Peacock system for multileaf intensity modulation collimator
    • Wu A., Johnson M., Chen A.S.J., et al. Evaluation of dose algorithm of Peacock system for multileaf intensity modulation collimator. Int J Radiat Oncol Biol Phys. 36:1996;1225-1231.
    • (1996) Int J Radiat Oncol Biol Phys , vol.36 , pp. 1225-1231
    • Wu, A.1    Johnson, M.2    Chen, A.S.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.