메뉴 건너뛰기




Volumn 55, Issue 1, 2000, Pages 65-73

Applications of simulator computed tomography number for photon dose calculations during radiotherapy treatment planning

Author keywords

Computed tomography; Computed tomography number; Dose calculation; Simulator; Treatment planning

Indexed keywords

ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; LIGHT; PHANTOM; PRIORITY JOURNAL; RADIATION DOSE; SIMULATION; TREATMENT PLANNING;

EID: 0034175732     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-8140(00)00159-6     Document Type: Article
Times cited : (44)

References (24)
  • 1
    • 0024424112 scopus 로고
    • Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media
    • Ahnesjo A. Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media. Med. Phys. 16:1989;577-592.
    • (1989) Med. Phys. , vol.16 , pp. 577-592
    • Ahnesjo, A.1
  • 2
    • 0020060565 scopus 로고
    • Patient beam positioning system using CT images
    • Endo M., Kutsutani-Nakmara Y. Patient beam positioning system using CT images. Phys. Med. Biol. 27:1982;301-305.
    • (1982) Phys. Med. Biol. , vol.27 , pp. 301-305
    • Endo, M.1    Kutsutani-Nakmara, Y.2
  • 3
    • 0342679184 scopus 로고
    • Influence of CT number variations on absorbed dose calculations in CT based dose planning
    • Franklin P., Jessen K.A., Juul-Christensen J.M. Influence of CT number variations on absorbed dose calculations in CT based dose planning. Proc. Int. Symp. Dosimetry Radiother. IAEA-SM-298/7:1988;25-38.
    • (1988) Proc. Int. Symp. Dosimetry Radiother. , vol.2987 , pp. 25-38
    • Franklin, P.1    Jessen, K.A.2    Juul-Christensen, J.M.3
  • 4
    • 12644277570 scopus 로고
    • The CT simulator and the simulator CT: Advantages, disadvantages, and future developments in radiation therapy physics
    • A.R. Smith. New York: Springer-Verlag
    • Galvin J.M. The CT simulator and the simulator CT: advantages, disadvantages, and future developments in radiation therapy physics. Smith A.R. Radiation therapy physics. 1995;19-32 Springer-Verlag, New York.
    • (1995) Radiation Therapy Physics , pp. 19-32
    • Galvin, J.M.1
  • 5
    • 0017374949 scopus 로고
    • The use of CT scanners in megavoltage photon beam therapy planning
    • Geise R.A., McCullough E.C. The use of CT scanners in megavoltage photon beam therapy planning. Radiology. 124:1977;133-141.
    • (1977) Radiology , vol.124 , pp. 133-141
    • Geise, R.A.1    McCullough, E.C.2
  • 6
    • 0018411597 scopus 로고
    • Computed tomography in planning radiation therapy outcome
    • Goitein M. Computed tomography in planning radiation therapy outcome. Int. J. Radiat. Oncol. Biol. Phys. 5:1979;445-447.
    • (1979) Int. J. Radiat. Oncol. Biol. Phys. , vol.5 , pp. 445-447
    • Goitein, M.1
  • 7
    • 0017899102 scopus 로고
    • The determination of anatomical cross-sections using a radiotherapy simulator
    • Harrison R.M., Farmer F.T. The determination of anatomical cross-sections using a radiotherapy simulator. Br. J. Radiol. 51:1978;448-453.
    • (1978) Br. J. Radiol. , vol.51 , pp. 448-453
    • Harrison, R.M.1    Farmer, F.T.2
  • 9
    • 0019174428 scopus 로고
    • Comparison of equivalent photon energy calibration methods in computed tomography
    • Judy P.F., Adler G.J. Comparison of equivalent photon energy calibration methods in computed tomography. Med. Phys. 7:1980;685-691.
    • (1980) Med. Phys. , vol.7 , pp. 685-691
    • Judy, P.F.1    Adler, G.J.2
  • 10
    • 0018099871 scopus 로고
    • The use of computed tomography data for radiotherapy dose calculations
    • Kijewski P.K., Bjarngard B.E. The use of computed tomography data for radiotherapy dose calculations. Int. J. Radiat. Oncol. Biol. Phys. 4:1978;429-435.
    • (1978) Int. J. Radiat. Oncol. Biol. Phys. , vol.4 , pp. 429-435
    • Kijewski, P.K.1    Bjarngard, B.E.2
  • 13
    • 0020574481 scopus 로고
    • CT number variability in thoracic geometry
    • McCullough B.C., Morin R.L. CT number variability in thoracic geometry. Am J. Roentgenol. 141:1983;135-140.
    • (1983) Am J. Roentgenol. , vol.141 , pp. 135-140
    • McCullough, B.C.1    Morin, R.L.2
  • 14
    • 0343549410 scopus 로고
    • CT simulation for radiotherapy: The Royal North Shore experience with the Varian CT option
    • S.K. Jani. Madison: Medical Physics Publishing
    • Mallik R., Hunt P., Seppi B., Shapiro E., Pavkovich J., Henderson S. CT simulation for radiotherapy: the Royal North Shore experience with the Varian CT option. Jani S.K. CT simulation for radiotherapy. 1993;87-107 Medical Physics Publishing, Madison.
    • (1993) CT Simulation for Radiotherapy , pp. 87-107
    • Mallik, R.1    Hunt, P.2    Seppi, B.3    Shapiro, E.4    Pavkovich, J.5    Henderson, S.6
  • 17
    • 38249013626 scopus 로고
    • Photon dose calculations for three-dimensional radiation treatment planning
    • Purdy J.A. Photon dose calculations for three-dimensional radiation treatment planning. Seminar Radiat. Oncol. 2:1992;235-245.
    • (1992) Seminar Radiat. Oncol. , vol.2 , pp. 235-245
    • Purdy, J.A.1
  • 23
    • 0343113479 scopus 로고    scopus 로고
    • Patient's set-up reproducibility on conventional CT and simulator CT.
    • Abstract
    • Wang X., Kulig P., Worley S., Chu J. Patient's set-up reproducibility on conventional CT and simulator CT. Abstract Med. Phys. 24:1997;1363.
    • (1997) Med. Phys. , vol.24 , pp. 1363
    • Wang, X.1    Kulig, P.2    Worley, S.3    Chu, J.4
  • 24
    • 0025671743 scopus 로고
    • Non-standard CT scanner: Their role in radiotherapy
    • Webb S. Non-standard CT scanner: their role in radiotherapy. Int. J. Radiat. Oncol. Biol. Phys. 19:1990;1589-1607.
    • (1990) Int. J. Radiat. Oncol. Biol. Phys. , vol.19 , pp. 1589-1607
    • Webb, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.