메뉴 건너뛰기




Volumn 20, Issue 6, 2000, Pages 499-513

Comparison of the predicted and experimental heat transfer performance of a finned tube evaporator

Author keywords

[No Author keywords available]

Indexed keywords

AIR CONDITIONING; FINS (HEAT EXCHANGE); HEAT TRANSFER; REFRIGERANTS; STEAM POWER PLANTS; TUBES (COMPONENTS);

EID: 0034174073     PISSN: 13594311     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1359-4311(99)00037-X     Document Type: Article
Times cited : (20)

References (15)
  • 2
    • 0030182556 scopus 로고    scopus 로고
    • A numerical and experimental study of turbulent flow through the evaporator coil in an air-conditioning unit
    • Z.G. Xu et al., A numerical and experimental study of turbulent flow through the evaporator coil in an air-conditioning unit, Int. J. Refrig. 19 (6) (1996) 369-381.
    • (1996) Int. J. Refrig. , vol.19 , Issue.6 , pp. 369-381
    • Xu, Z.G.1
  • 4
    • 85031581993 scopus 로고    scopus 로고
    • Heat Transfer and Fluid Flow Service, National Engineering Laboratory, East Kilbride, Glasgow G75 OQU
    • ACOL5 program user manual. Heat Transfer and Fluid Flow Service, National Engineering Laboratory, East Kilbride, Glasgow G75 OQU.
    • ACOL5 Program User Manual
  • 5
    • 0034174176 scopus 로고    scopus 로고
    • Airflow maldistribution and the performance of a packaged air-conditioning evaporator
    • A.A. Aganda, J.E.R. Coney, C.G.W. Sheppard, Airflow maldistribution and the performance of a packaged air-conditioning evaporator, Applied Thermal Engineering 20(6) (2000) 515-528.
    • (2000) Applied Thermal Engineering , vol.20 , Issue.6 , pp. 515-528
    • Aganda, A.A.1    Coney, J.E.R.2    Sheppard, C.G.W.3
  • 6
    • 85031583333 scopus 로고
    • Heat transfer and drop characteristics of dry tower extended surfaces
    • PFR Engineering Systems Inc. prepared for the Dry Cooling Tower Program, Battelle Memorial Institute, Richland Washington, under Special Agreement BSA-988, Marina del Rey, CA, USA
    • PFR Engineering Systems Inc., Heat transfer and drop characteristics of dry tower extended surfaces. Part I: Heat transfer and pressure drop data, BNWL-PFR7-100. Part II: Data analysis and correlation BNWL-PFR7-102, prepared for the Dry Cooling Tower Program, Battelle Memorial Institute, Richland Washington, under Special Agreement BSA-988, Marina del Rey, CA, USA, 1976.
    • (1976) Part I: Heat Transfer and Pressure Drop Data, BNWL-PFR7-100. Part II: Data Analysis and Correlation BNWL-PFR7-102
  • 8
    • 0017931161 scopus 로고
    • Heat and mass transfer characteristics of a cooling and humidity coil and the effect of upstream turbulence on them
    • Nagaraja S., Krishna Murthy M.V. Heat and mass transfer characteristics of a cooling and humidity coil and the effect of upstream turbulence on them. Int. J. Heat and Mass Transfer. 21:1978;87.
    • (1978) Int. J. Heat and Mass Transfer , vol.21 , pp. 87
    • Nagaraja, S.1    Krishna Murthy, M.V.2
  • 9
    • 0016452079 scopus 로고
    • The effect of the number of tube rows on heat transfer performance of smooth plate fin-and-tube heat exchangers
    • Rich D.G. The effect of the number of tube rows on heat transfer performance of smooth plate fin-and-tube heat exchangers. ASHRAE Trans. 81:(1):1975;307-309.
    • (1975) ASHRAE Trans , vol.81 , Issue.1 , pp. 307-309
    • Rich, D.G.1
  • 10
    • 0016093659 scopus 로고
    • Local and average transfer coefficients for one-row plate fin and tube heat exchangers
    • Saboya F.E.M., Sparrow E.M. Local and average transfer coefficients for one-row plate fin and tube heat exchangers. Trans. ASME J. Heat Transfer, Series C. 96:1974;265-272.
    • (1974) Trans. ASME J. Heat Transfer, Series C , vol.96 , pp. 265-272
    • Saboya, F.E.M.1    Sparrow, E.M.2
  • 11
    • 0002358243 scopus 로고
    • Transfers characteristics of two-row plate fin and tube heat exchanger configurations
    • Saboya F.E.M., Sparrow E.M. Transfers characteristics of two-row plate fin and tube heat exchanger configurations. Int. J. Heat and Mass Transfer. 19:1976;41-49.
    • (1976) Int. J. Heat and Mass Transfer , vol.19 , pp. 41-49
    • Saboya, F.E.M.1    Sparrow, E.M.2
  • 13
    • 0020593077 scopus 로고
    • The effect of fin shape, fin attachment, and transverse row number on the heat transfer and pressure drop of typical air-cooler finned tubes
    • in: Y. Mori, W.J. Wang (Eds.) Honolulu, Hawaii, USA, 20-24 March, ASME Book I00158-A, LCCN 74234
    • P.W. Eckels, T.J. Rabas, The effect of fin shape, fin attachment, and transverse row number on the heat transfer and pressure drop of typical air-cooler finned tubes, in: Y. Mori, W.J. Wang (Eds.), ASME/JSME Thermal Engineering, Joint Conference, Honolulu, Hawaii, USA, 20-24 March, ASME Book I00158-A, LCCN 74234, vol. 1, 1983, pp. 451-459.
    • (1983) ASME/JSME Thermal Engineering, Joint Conference , vol.1 , pp. 451-459
    • Eckels, P.W.1    Rabas, T.J.2
  • 15
    • 85007710121 scopus 로고
    • Level and average heat transfer and pressure drop for refrigerant evaporating in horizontal tubes
    • M. Altaman et al., Level and average heat transfer and pressure drop for refrigerant evaporating in horizontal tubes, Trans ASME J. Heat Transfer (1960) 189-198.
    • (1960) Trans ASME J. Heat Transfer , pp. 189-198