메뉴 건너뛰기




Volumn 15, Issue 2, 2000, Pages 756-763

Surge protection of underground distribution cables

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; CURRENT LIMITING REACTORS; ELECTRIC POTENTIAL; LIGHTNING; LIGHTNING ARRESTERS; OVERVOLTAGE PROTECTION; SURGE PROTECTION; TRANSIENTS; UNDERGROUND CABLES;

EID: 0034171534     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/61.853016     Document Type: Article
Times cited : (19)

References (10)
  • 2
    • 0019543797 scopus 로고
    • The application of gapless arresters on distribution systems
    • Mar.
    • J. J. Burke, E. C. Sakshaug, and S. L. Smith, "The application of gapless arresters on distribution systems," IEEE Trans. on Power Apparatus and Systems, vol. 100, no. 3, pp. 1234-1243, Mar. 1981.
    • (1981) IEEE Trans. on Power Apparatus and Systems , vol.100 , Issue.3 , pp. 1234-1243
    • Burke, J.J.1    Sakshaug, E.C.2    Smith, S.L.3
  • 3
    • 0023670492 scopus 로고
    • A simplified method for surge protection of underground distribution systems with metal oxide arresters
    • Oct.
    • M. V. Lat, "A simplified method for surge protection of underground distribution systems with metal oxide arresters," IEEE Trans. on Power Delivery, vol. 2, no. 4, pp. 1110-1116, Oct. 1987.
    • (1987) IEEE Trans. on Power Delivery , vol.2 , Issue.4 , pp. 1110-1116
    • Lat, M.V.1
  • 4
    • 0018445509 scopus 로고
    • Influence of rate-of-rise on distribution arrester protective characteristics
    • Mar./Apr.
    • E. C. Sakshaug, "Influence of rate-of-rise on distribution arrester protective characteristics," IEEE Trans. on Power Apparatus and Systems, vol. 98, no. 2, pp. 519-526, Mar./Apr. 1979.
    • (1979) IEEE Trans. on Power Apparatus and Systems , vol.98 , Issue.2 , pp. 519-526
    • Sakshaug, E.C.1
  • 5
    • 0026763601 scopus 로고
    • Modeling of metal oxide surge arresters
    • Jan.
    • IEEE Working Group 3.4.11, "Modeling of metal oxide surge arresters," IEEE Trans. on Power Delivery, vol. 7, no. 1, pp. 302-309, Jan. 1992.
    • (1992) IEEE Trans. on Power Delivery , vol.7 , Issue.1 , pp. 302-309
  • 6
    • 0030127432 scopus 로고    scopus 로고
    • Study of ZnO arrester model for steep front wave
    • Apr.
    • I. Kim et al., "Study of ZnO arrester model for steep front wave," IEEE Trans. on Power Delivery, vol. 11, no. 2, pp. 834-841, Apr. 1996.
    • (1996) IEEE Trans. on Power Delivery , vol.11 , Issue.2 , pp. 834-841
    • Kim, I.1
  • 8
    • 0001822192 scopus 로고
    • Lightning parameters for engineering application
    • Mar.
    • R. B. Anderson and A. J. Erikmon, "Lightning parameters for engineering application," Electra, no. 69, pp. 65-102, Mar. 1980.
    • (1980) Electra , Issue.69 , pp. 65-102
    • Anderson, R.B.1    Erikmon, A.J.2
  • 9
    • 0017995297 scopus 로고
    • Surge protection of UD cable systems. Part 1: Cable attenuation and protection constraints
    • July/Aug.
    • R. E. Owen and C. R. Clinkenbeard, "Surge protection of UD cable systems. Part 1: Cable attenuation and protection constraints," IEEE Trans. on Power Apparatus and Systems, vol. 97, no. 4, pp. 1319-1327, July/Aug. 1978.
    • (1978) IEEE Trans. on Power Apparatus and Systems , vol.97 , Issue.4 , pp. 1319-1327
    • Owen, R.E.1    Clinkenbeard, C.R.2
  • 10
    • 0025212395 scopus 로고
    • Voltage quadrupling on a UD cable
    • Jan.
    • P. P. Baker, "Voltage quadrupling on a UD cable," IEEE Trans on Power Delivery, vol. 5, no. 1, pp. 493-501, Jan. 1990.
    • (1990) IEEE Trans on Power Delivery , vol.5 , Issue.1 , pp. 493-501
    • Baker, P.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.