메뉴 건너뛰기




Volumn 89, Issue 4, 2000, Pages 522-529

The oblique radiographic technique for bone height measurements on edentulous mandibles: A preclinical study and an introduction to the clinical use

Author keywords

[No Author keywords available]

Indexed keywords

ANALYSIS OF VARIANCE; ARTICLE; BONE; COMPARATIVE STUDY; EDENTULOUSNESS; HUMAN; IN VITRO STUDY; INSTRUMENTATION; MANDIBLE; METHODOLOGY; OBSERVER VARIATION; RADIOGRAPHY; STATISTICS; TOOTH RADIOGRAPHY;

EID: 0034166745     PISSN: 10792104     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1079-2104(00)70135-1     Document Type: Article
Times cited : (11)

References (26)
  • 2
    • 0023672133 scopus 로고
    • Bone resorption in edentulous patients treated with mandibular fixed tissue integrated prostheses
    • LW Lindquist B Rockler GE. Carlsson Bone resorption in edentulous patients treated with mandibular fixed tissue integrated prostheses J Prosthet Dent 59 1988 59 63
    • (1988) J Prosthet Dent , vol.59 , pp. 59-63
    • Lindquist, LW1    Rockler, B2    Carlsson, GE.3
  • 3
    • 70349143404 scopus 로고
    • Evaluation of bone loss around the neck of endosseous implants in the mandible. Analysis of bone loss around implants
    • HJ Meijer WH Steen F. Bosman Evaluation of bone loss around the neck of endosseous implants in the mandible. Analysis of bone loss around implants Oral Surg Oral Med Oral Pathol 2 1991 55 57
    • (1991) Oral Surg Oral Med Oral Pathol , vol.2 , pp. 55-57
    • Meijer, HJ1    Steen, WH2    Bosman, F.3
  • 4
    • 0031253968 scopus 로고    scopus 로고
    • Interposed bone grafts to accommodate endosteal implants for retaining mandibular overdentures. A 1-7 year follow-up study
    • S Satow AP Slagter PJ Stoelinga LL. Habets Interposed bone grafts to accommodate endosteal implants for retaining mandibular overdentures. A 1-7 year follow-up study Int J Oral Maxillofac Surg 26 1997 358 364
    • (1997) Int J Oral Maxillofac Surg , vol.26 , pp. 358-364
    • Satow, S1    Slagter, AP2    Stoelinga, PJ3    Habets, LL.4
  • 5
    • 0031253917 scopus 로고    scopus 로고
    • The combined use of endosteal implants and iliac crest onlay grafts in the severely atrophic mandible: a longitudinal study
    • JW Verhoeven MS Cune M Terlou MA Zoon C. de Putter The combined use of endosteal implants and iliac crest onlay grafts in the severely atrophic mandible: a longitudinal study Int J Oral Maxillofac Surg 26 1997 351 357
    • (1997) Int J Oral Maxillofac Surg , vol.26 , pp. 351-357
    • Verhoeven, JW1    Cune, MS2    Terlou, M3    Zoon, MA4    de Putter, C.5
  • 6
    • 0031613260 scopus 로고    scopus 로고
    • Effect of prefabricated bar design with implant-stabilized prostheses on ridge resorption: a clinical report
    • PS Wright RM. Watson Effect of prefabricated bar design with implant-stabilized prostheses on ridge resorption: a clinical report Int J Oral Maxillofac Implants 13 1998 77 81
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 77-81
    • Wright, PS1    Watson, RM.2
  • 7
    • 0026905816 scopus 로고
    • Standardized radiographs of the alveolar crest around implants in the mandible
    • HJ Meijer WH Steen F. Bosman Standardized radiographs of the alveolar crest around implants in the mandible J Prosthet Dent 68 1992 318 321
    • (1992) J Prosthet Dent , vol.68 , pp. 318-321
    • Meijer, HJ1    Steen, WH2    Bosman, F.3
  • 8
    • 0027653471 scopus 로고
    • Radiological evaluation of marginal bone loss at tooth surfaces facing single Branemark implants
    • M Esposito A Ekestubbe K. Grondahl Radiological evaluation of marginal bone loss at tooth surfaces facing single Branemark implants Clin Oral Implants Res 4 1993 151 157
    • (1993) Clin Oral Implants Res , vol.4 , pp. 151-157
    • Esposito, M1    Ekestubbe, A2    Grondahl, K.3
  • 9
    • 0023446093 scopus 로고
    • The use of panoramic radiographs to measure alveolar bone areas
    • RJC Wilding I Levin R. Pepper The use of panoramic radiographs to measure alveolar bone areas J Oral Rehabil 14 1987 557 567
    • (1987) J Oral Rehabil , vol.14 , pp. 557-567
    • Wilding, RJC1    Levin, I2    Pepper, R.3
  • 11
    • 0028041216 scopus 로고
    • The transmandibular implant: from progressive bone loss to controlled bone growth
    • MP Powers H Bosker AW van Pelt N. Dunbar The transmandibular implant: from progressive bone loss to controlled bone growth J Oral Maxillofac Surg 52 1994 904 910
    • (1994) J Oral Maxillofac Surg , vol.52 , pp. 904-910
    • Powers, MP1    Bosker, H2    van Pelt, AW3    Dunbar, N.4
  • 15
    • 0030077250 scopus 로고    scopus 로고
    • Clinical aspects of a multicenter clinical trial of implant-retained mandibular overdentures in patients with severely resorbed mandibles
    • ME Geertman EM Boerrigter MA Van Waas RP. van Oort Clinical aspects of a multicenter clinical trial of implant-retained mandibular overdentures in patients with severely resorbed mandibles J Prosthet Dent 75 1996 194 204
    • (1996) J Prosthet Dent , vol.75 , pp. 194-204
    • Geertman, ME1    Boerrigter, EM2    Van Waas, MA3    van Oort, RP.4
  • 16
    • 0019848361 scopus 로고
    • Image distortion in rotational panoramic radiography. I. General considerations
    • G Tronje U Welander WD McDavid CR. Morris Image distortion in rotational panoramic radiography. I. General considerations Acta Radiol Diagn Stockh 22 1981 295 299
    • (1981) Acta Radiol Diagn Stockh , vol.22 , pp. 295-299
    • Tronje, G1    Welander, U2    McDavid, WD3    Morris, CR.4
  • 17
    • 0019837709 scopus 로고
    • Image distortion in rotational panoramic radiography. II. Vertical distances
    • G Tronje S Eliasson P Julin U. Welander Image distortion in rotational panoramic radiography. II. Vertical distances Acta Radiol Diagn Stockh 22 1981 449 455
    • (1981) Acta Radiol Diagn Stockh , vol.22 , pp. 449-455
    • Tronje, G1    Eliasson, S2    Julin, P3    Welander, U.4
  • 18
    • 0019834608 scopus 로고
    • Image distortion in rotational panoramic radiography. III. Inclined objects
    • G Tronje U Welander WD McDavid CR. Morris Image distortion in rotational panoramic radiography. III. Inclined objects Acta Radiol Diagn Stockh 22 1981 585 592
    • (1981) Acta Radiol Diagn Stockh , vol.22 , pp. 585-592
    • Tronje, G1    Welander, U2    McDavid, WD3    Morris, CR.4
  • 20
    • 0015291714 scopus 로고
    • The continuing reduction of the residual alveolar ridges in complete denture wearers: a mixed-longitudinal study covering 25 years
    • A. Tallgren The continuing reduction of the residual alveolar ridges in complete denture wearers: a mixed-longitudinal study covering 25 years J Prosthet Dent 27 1972 120 132
    • (1972) J Prosthet Dent , vol.27 , pp. 120-132
    • Tallgren, A.1
  • 21
    • 12644252164 scopus 로고
    • Improved radiographic results in cephalometry through the use of high kilovoltage
    • LJ Cartwright E. Harvold Improved radiographic results in cephalometry through the use of high kilovoltage Can Dent Assoc 20 1954 261
    • (1954) Can Dent Assoc , vol.20 , pp. 261
    • Cartwright, LJ1    Harvold, E.2
  • 23
    • 0025968194 scopus 로고
    • Measuring mandibular ridge reduction on oblique cephalometric radiographs
    • RE Jonkman MA Van Waas J Plooij W. Kalk Measuring mandibular ridge reduction on oblique cephalometric radiographs J Craniomaxillofac Surg 19 1991 27 30
    • (1991) J Craniomaxillofac Surg , vol.19 , pp. 27-30
    • Jonkman, RE1    Van Waas, MA2    Plooij, J3    Kalk, W.4
  • 24
    • 14244266963 scopus 로고
    • Measuring mandibular ridge reduction [thesis]
    • WHA. Steen Measuring mandibular ridge reduction [thesis] 1984 University of Utrecht The Netherlands
    • (1984)
    • Steen, WHA.1
  • 25
    • 0033278015 scopus 로고    scopus 로고
    • Smallest detectable difference in outcome variables related to painful restriction of the temporomandibular joint
    • TJ Kropmans PU Dijkstra B Stegenga Stewart LG. de Bont Smallest detectable difference in outcome variables related to painful restriction of the temporomandibular joint J Dent Res 78 1999 784 789
    • (1999) J Dent Res , vol.78 , pp. 784-789
    • Kropmans, TJ1    Dijkstra, PU2    Stegenga, B3    Stewart4    de Bont, LG.5
  • 26
    • 0021400783 scopus 로고
    • Errors in oblique cephalometric radiographic projections of the edentulous mandible. Part I: Geometric errors
    • WH. Steen Errors in oblique cephalometric radiographic projections of the edentulous mandible. Part I: Geometric errors J Prosthet Dent 51 1984 411 418
    • (1984) J Prosthet Dent , vol.51 , pp. 411-418
    • Steen, WH.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.