-
1
-
-
0025272377
-
Receiver operating characteristic analysis of chest image interpretation with conventional, laser-printed, and high-resolution workstation images
-
Slasky B.S., Gur D. Receiver operating characteristic analysis of chest image interpretation with conventional, laser-printed, and high-resolution workstation images. Radiology. 174:1990;775-780.
-
(1990)
Radiology
, vol.174
, pp. 775-780
-
-
Slasky, B.S.1
Gur, D.2
-
2
-
-
0028326457
-
Digital radiography and conventional imaging of the chest: A comparison of observer performance
-
Thaete F.L., Fuhrman C.R. Digital radiography and conventional imaging of the chest: a comparison of observer performance. Am. J. Roentgenol. 162:1994;575-581.
-
(1994)
Am. J. Roentgenol.
, vol.162
, pp. 575-581
-
-
Thaete, F.L.1
Fuhrman, C.R.2
-
3
-
-
0022640460
-
Digital and conventional chest images: Observer performance with film digital radiography system
-
Lawrence R.G., Foley W.D., Charles R.W., Alfred A.R., Thomas L.L. Digital and conventional chest images: observer performance with film digital radiography system. Radiology. 158:1986;27-33.
-
(1986)
Radiology
, vol.158
, pp. 27-33
-
-
Lawrence, R.G.1
Foley, W.D.2
Charles, R.W.3
Alfred, A.R.4
Thomas, L.L.5
-
4
-
-
0024502978
-
Comparison of 2048-line digital display formats and conventional radiographs: An ROC study
-
Alek H., Denise R.A., Huang H.K.et al. Comparison of 2048-line digital display formats and conventional radiographs: an ROC study. AJR. 152:1989;1113-1119.
-
(1989)
AJR
, vol.152
, pp. 1113-1119
-
-
Alek, H.1
Denise, R.A.2
Huang, H.K.3
-
5
-
-
0024578626
-
Detection of pneumothorax: Comparison of digital and conventional chest imaging
-
Fajardo L.L., Hillman B.J., Pond G.D., Carmody R.F., Johnson J.E., Ferrell W.R. Detection of pneumothorax: comparison of digital and conventional chest imaging. Am. J. Roentgenol. 152:1989;475-480.
-
(1989)
Am. J. Roentgenol.
, vol.152
, pp. 475-480
-
-
Fajardo, L.L.1
Hillman, B.J.2
Pond, G.D.3
Carmody, R.F.4
Johnson, J.E.5
Ferrell, W.R.6
-
6
-
-
0025279711
-
The effect of image processing on chest radiograph interpretations in a PACS environment
-
Marcs S.R., Walter F.G., Maria A.C.et al. The effect of image processing on chest radiograph interpretations in a PACS environment. Invest. Radiol. 25:1990;897-901.
-
(1990)
Invest. Radiol.
, vol.25
, pp. 897-901
-
-
Marcs, S.R.1
Walter, F.G.2
Maria, A.C.3
-
7
-
-
0024095767
-
Evaluation of digital unsharp masing and local contrast stretching as applied to chest radiographs
-
Jadwiga R., Kendall P., Donald S. Evaluation of digital unsharp masing and local contrast stretching as applied to chest radiographs. IEEE Trans. Biomed. Eng. 35:1988;817-827.
-
(1988)
IEEE Trans. Biomed. Eng.
, vol.35
, pp. 817-827
-
-
Jadwiga, R.1
Kendall, P.2
Donald, S.3
-
8
-
-
0021621236
-
An adaptive edge and contrast enhancement technique based on unsharp masking
-
Mahmoodi A.B., Nelson O.L. An adaptive edge and contrast enhancement technique based on unsharp masking. Proc. Soc. Photo-Opt. Instrum. 454:1984;326-330.
-
(1984)
Proc. Soc. Photo-Opt. Instrum.
, vol.454
, pp. 326-330
-
-
Mahmoodi, A.B.1
Nelson, O.L.2
-
9
-
-
0026577701
-
A fully automated adaptive unsharp masking technique in digital chest radiograph
-
Katsumi A., Shigehiko K., Yasuo S., Toru Y. A fully automated adaptive unsharp masking technique in digital chest radiograph. Invest. Radiol. 27:1992;64-70.
-
(1992)
Invest. Radiol.
, vol.27
, pp. 64-70
-
-
Katsumi, A.1
Shigehiko, K.2
Yasuo, S.3
Toru, Y.4
-
10
-
-
0028727573
-
Adaptive image contrast enhancement based on human visual properties
-
Ji T.L., Sundareshan M.K., Roehrig H. Adaptive image contrast enhancement based on human visual properties. IEEE Trans. Med. Imag. 10:1994;573-586.
-
(1994)
IEEE Trans. Med. Imag.
, vol.10
, pp. 573-586
-
-
Ji, T.L.1
Sundareshan, M.K.2
Roehrig, H.3
-
12
-
-
0031910608
-
Detection of small low-contrast objects in mammography: Effect of viewbox masking and luminance
-
Wang J., Gray J.E. Detection of small low-contrast objects in mammography: effect of viewbox masking and luminance. Am. J. Roentgenol. 170:1998;105-108.
-
(1998)
Am. J. Roentgenol.
, vol.170
, pp. 105-108
-
-
Wang, J.1
Gray, J.E.2
-
13
-
-
84975604875
-
Contrast in complex images
-
Peli E. Contrast in complex images. J. Opt. Soc. Am. A. 10:1990;2032-2040.
-
(1990)
J. Opt. Soc. Am. a
, vol.10
, pp. 2032-2040
-
-
Peli, E.1
-
14
-
-
0024735541
-
The effects of picture size and definition on perceived image quality
-
Barten G.J. The effects of picture size and definition on perceived image quality. IEEE Trans. Electr. Dev. 36:1989;1865-1869.
-
(1989)
IEEE Trans. Electr. Dev.
, vol.36
, pp. 1865-1869
-
-
Barten, G.J.1
-
15
-
-
85076881189
-
The visible differences predictor: An algorithm for the assessment of image fidelity
-
Daly S. The visible differences predictor: an algorithm for the assessment of image fidelity. Proc. Soc. Photo-Opt. Instrum. 1666:1992;2-15.
-
(1992)
Proc. Soc. Photo-Opt. Instrum.
, vol.1666
, pp. 2-15
-
-
Daly, S.1
-
16
-
-
0025144117
-
Chest radiography: Comparison of high-resolution digital displays with conventional and digital film
-
Cox G.G., Cook L.T., McMillan J.H., Rosenthal S.J., Dwyer S.J. Chest radiography: comparison of high-resolution digital displays with conventional and digital film. Radiology. 176:1990;771-776.
-
(1990)
Radiology
, vol.176
, pp. 771-776
-
-
Cox, G.G.1
Cook, L.T.2
McMillan, J.H.3
Rosenthal, S.J.4
Dwyer, S.J.5
|