메뉴 건너뛰기




Volumn 29, Issue 2, 2000, Pages 97-102

Digitisation and display of intra-oral films

Author keywords

Digital radiography, dental; Image processing, computer assisted; Perception; Radiographic image enhancement

Indexed keywords

ALGORITHM; ARTICLE; CANINE TOOTH; COLOR; HUMAN; IMAGE PROCESSING; IMAGE QUALITY; INCISOR; INFORMATION PROCESSING; INSTRUMENTATION; METHODOLOGY; MOLAR TOOTH; OBSERVER VARIATION; PREMOLAR TOOTH; RADIOGRAPHY; STATISTICS; TOOTH RADIOGRAPHY; X RAY FILM;

EID: 0034156935     PISSN: 0250832X     EISSN: None     Source Type: Journal    
DOI: 10.1038/sj.dmfr.4600511     Document Type: Article
Times cited : (23)

References (23)
  • 1
    • 0027737815 scopus 로고
    • Digital radiology: Facts and fictions
    • Dunn SM, Kantor ML. Digital radiology: Facts and fictions. JADA 1993; 124: 39-47.
    • (1993) JADA , vol.124 , pp. 39-47
    • Dunn, S.M.1    Kantor, M.L.2
  • 3
    • 0027639992 scopus 로고
    • Perception of image quality in direct digital radiography after application of various image treatment filters for the detect ability of dental disease
    • Wenzel A, Hintze H. Perception of image quality in direct digital radiography after application of various image treatment filters for the detect ability of dental disease. Dentomaxillofac Radiol 1993; 22: 131-134.
    • (1993) Dentomaxillofac Radiol , vol.22 , pp. 131-134
    • Wenzel, A.1    Hintze, H.2
  • 4
    • 0020710472 scopus 로고
    • Subtraction radiography for the diagnosis of periodontal bone lesions
    • Gröndahl H-G, Gröndahl K. Subtraction radiography for the diagnosis of periodontal bone lesions. Oral Surg Oral Med Oral Pathol 1983, 55: 208-213.
    • (1983) Oral Surg Oral Med Oral Pathol , vol.55 , pp. 208-213
    • Gröndahl, H.-G.1    Gröndahl, K.2
  • 5
    • 0023968096 scopus 로고
    • Detsetability of artificial marginal bone lesions as a function of lesion depth. A comparison between subtraction radiography and conventional radiographic technique
    • Gröndahl K, Kullendorff B, Strid K-G, Gröndahl H-G, Henrikson CO. Detsetability of artificial marginal bone lesions as a function of lesion depth. A comparison between subtraction radiography and conventional radiographic technique. J Clin Periodontol 1988; 15: 156-162.
    • (1988) J Clin Periodontol , vol.15 , pp. 156-162
    • Gröndahl, K.1    Kullendorff, B.2    Strid, K.-G.3    Gröndahl, H.-G.4    Henrikson, C.O.5
  • 6
    • 0039784978 scopus 로고    scopus 로고
    • Technical comparison of seven digital intra-oral dental X-ray sensors
    • abstract
    • Vandre RH, Pajak JC, Farman TT, Farman AG. Technical comparison of seven digital intra-oral dental X-ray sensors. Dentomaxillofac Radiol 1997; 26: 282-283 (abstract).
    • (1997) Dentomaxillofac Radiol , vol.26 , pp. 282-283
    • Vandre, R.H.1    Pajak, J.C.2    Farman, T.T.3    Farman, A.G.4
  • 7
    • 0032059362 scopus 로고    scopus 로고
    • The development of a new direct digital extra-oral radiographic system prototype using a thin-film transistor panel
    • Sakurai T, Matsuki T, Nakamura K, et al. The development of a new direct digital extra-oral radiographic system prototype using a thin-film transistor panel. Dentomaxillofac Radiol 1998; 27: 172-177.
    • (1998) Dentomaxillofac Radiol , vol.27 , pp. 172-177
    • Sakurai, T.1    Matsuki, T.2    Nakamura, K.3
  • 8
    • 0028541775 scopus 로고
    • When will excellent radiographic images be available to the general dental office ?
    • Lavelle CLB, Wu C-J. When will excellent radiographic images be available to the general dental office ? Dentornaxillafac Radiol 1994; 23: 183-191.
    • (1994) Dentornaxillafac Radiol , vol.23 , pp. 183-191
    • Lavelle, C.L.B.1    Wu, C.-J.2
  • 9
    • 0028440181 scopus 로고
    • Factors determining the diagnostic accuracy of digitized conventional intra-oral radiographs
    • Ohki M, Okano T, Nakamura T. Factors determining the diagnostic accuracy of digitized conventional intra-oral radiographs. Dentomaxillofac Radiol 1994; 23: 77-82.
    • (1994) Dentomaxillofac Radiol , vol.23 , pp. 77-82
    • Ohki, M.1    Okano, T.2    Nakamura, T.3
  • 10
    • 0028540888 scopus 로고
    • The effect of cathode ray tube display format on observer performance in dental digitized radiography: Comparison with plain films
    • Møystad A, Svanaes DB, Larheim TA, Gröndahl H-G. The effect of cathode ray tube display format on observer performance in dental digitized radiography: comparison with plain films. Dentomaxillofac Radiol 1994; 23: 206-210.
    • (1994) Dentomaxillofac Radiol , vol.23 , pp. 206-210
    • Møystad, A.1    Svanaes, D.B.2    Larheim, T.A.3    Gröndahl, H.-G.4
  • 11
    • 0029395615 scopus 로고
    • Effect of image magnification of digitized bitewing radiographs on approximal caries detection: An in vitro study
    • Møystad A, Svanæs DB, Larheim TA, Gröndahl H-G. Effect of image magnification of digitized bitewing radiographs on approximal caries detection: an in vitro study. Dentomaxillofac Radiol 1995; 24: 255-259.
    • (1995) Dentomaxillofac Radiol , vol.24 , pp. 255-259
    • Møystad, A.1    Svanæs, D.B.2    Larheim, T.A.3    Gröndahl, H.-G.4
  • 12
    • 0026903337 scopus 로고
    • A comparison of conventional intraoral radiography and computer imaging techniques for the detection of proximal surface dental caries
    • Dove SB, McDavid WD. A comparison of conventional intraoral radiography and computer imaging techniques for the detection of proximal surface dental caries. Dentomaxillofac Radiol 1992; 21: 127-134.
    • (1992) Dentomaxillofac Radiol , vol.21 , pp. 127-134
    • Dove, S.B.1    McDavid, W.D.2
  • 14
    • 0348058981 scopus 로고
    • Imaging properties of high resolution film scanners
    • abstract
    • Visser H, Ayabakan M. Imaging properties of high resolution film scanners, Dentomaxillfac Radiol 1995; 24: 84-85 (abstract).
    • (1995) Dentomaxillfac Radiol , vol.24 , pp. 84-85
    • Visser, H.1    Ayabakan, M.2
  • 16
    • 1542763925 scopus 로고
    • Belgium, Agfa-gevaert N.V.
    • Arcus II manual, Belgium, Agfa-gevaert N.V., 1994.
    • (1994) Arcus II Manual
  • 17
    • 1542449040 scopus 로고    scopus 로고
    • Finland, Nokia Products
    • Nokia 445Xi User's Guide, Finland, Nokia Products, 1996.
    • (1996) Nokia 445Xi User's Guide
  • 18
    • 0030112207 scopus 로고    scopus 로고
    • On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems
    • Borg E, Gröndahl H-G. On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems. Dentomaxillofac Radiol 1996; 25: 82-88.
    • (1996) Dentomaxillofac Radiol , vol.25 , pp. 82-88
    • Borg, E.1    Gröndahl, H.-G.2
  • 19
    • 1542763924 scopus 로고    scopus 로고
    • Observer performance on CRT displays with adjustable parameters
    • abstract
    • Wakoh M, Nishikawa K, Kuroyanagi K. Observer performance on CRT displays with adjustable parameters. Dentomaxillofac Radiol 1998; 27: 128 (abstract).
    • (1998) Dentomaxillofac Radiol , vol.27 , pp. 128
    • Wakoh, M.1    Nishikawa, K.2    Kuroyanagi, K.3
  • 21
    • 0026810468 scopus 로고
    • Comparison of photodensitometric with high-resolution digital analysis of bone density from serial dental radiographs
    • Dubrez B, Jacot-Descombes, Pun T, Cimasoni G. Comparison of photodensitometric with high-resolution digital analysis of bone density from serial dental radiographs. Dentomaxillofac Radiol 1992; 21: 40-44.
    • (1992) Dentomaxillofac Radiol , vol.21 , pp. 40-44
    • Dubrez, B.1    Jacot-Descombes2    Pun, T.3    Cimasoni, G.4
  • 22
    • 0029313035 scopus 로고
    • Computed dental radiography: Evaluation of a new charge-coupled device-based intra-oral radiographic system
    • Farman AG, Scarfe WC, Schick DB, Rumack PM. Computed dental radiography: Evaluation of a new charge-coupled device-based intra-oral radiographic system. Quintessence Int 1995; 26: 399-404.
    • (1995) Quintessence Int , vol.26 , pp. 399-404
    • Farman, A.G.1    Scarfe, W.C.2    Schick, D.B.3    Rumack, P.M.4
  • 23
    • 1542763922 scopus 로고    scopus 로고
    • Imaging properties of high resolution film scanners
    • abstract
    • Visser H, Ayabakan M. Imaging properties of high resolution film scanners. Dentomaxillofac Radiol 1998; 27: 84-85 (abstract).
    • (1998) Dentomaxillofac Radiol , vol.27 , pp. 84-85
    • Visser, H.1    Ayabakan, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.