Volumn 40, Issue 3, 2000, Pages 155-158

Influence of specimen size on the tension-tension fatigue behaviour of fibre-reinforced plastics at room temperature and at 77 K

Author keywords

[No Author keywords available]

Indexed keywords

FATIGUE TESTING; LOW TEMPERATURE EFFECTS; TENSILE TESTING;

EID: 0034155444     PISSN: 00112275     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0011-2275(00)00019-9     Document Type: Article
Times cited : (17)

References (9)
  • 2
    • 0025524583 scopus 로고
    • Test programme for mechanical strength measurements on fibre-reinforced plastics exposed to radiation environments
    • Weber H.W., Tschegg E. Test programme for mechanical strength measurements on fibre-reinforced plastics exposed to radiation environments. Adv Cryog Eng. 36:1990;869.
    • (1990) Adv Cryog Eng , vol.36 , pp. 869
    • Weber, H.W.1    Tschegg, E.2
  • 3
    • 0029537431 scopus 로고
    • Radiation effects on insulators for superconducting fusion magnets
    • Humer K., Weber H.W., Tschegg E.K. Radiation effects on insulators for superconducting fusion magnets. Cryogenics. 35:1995;871.
    • (1995) Cryogenics , vol.35 , pp. 871
    • Humer, K.1    Weber, H.W.2    Tschegg, E.K.3
  • 4
    • 0030213634 scopus 로고    scopus 로고
    • Low-temperature interlaminar shear strength of reactor irradiated glass-fibre-reinforced laminates
    • Humer K., Spießberger S., Weber H.W., Tschegg E.K., Gerstenberg H. Low-temperature interlaminar shear strength of reactor irradiated glass-fibre-reinforced laminates. Cryogenics. 36:1996;611.
    • (1996) Cryogenics , vol.36 , pp. 611
    • Humer, K.1    Spießberger, S.2    Weber, H.W.3    Tschegg, E.K.4    Gerstenberg, H.5
  • 5
    • 0342493164 scopus 로고    scopus 로고
    • Reactor irradiation effects on the ultimate tensile and the interlaminar shear strength of carbon fibre-reinforced epoxies at 77 K
    • Spießberger S., Humer K., Weber H.W., Tschegg E.K., Gerstenberg H. Reactor irradiation effects on the ultimate tensile and the interlaminar shear strength of carbon fibre-reinforced epoxies at 77 K. Cryogenics. 38:1998;79.
    • (1998) Cryogenics , vol.38 , pp. 79
    • Spießberger, S.1    Humer, K.2    Weber, H.W.3    Tschegg, E.K.4    Gerstenberg, H.5
  • 7
    • 0007647487 scopus 로고
    • ITER: The first experimental fusion reactor
    • Rebut P.-H. ITER: the first experimental fusion reactor. Fusion Eng Des. 30:1995;85.
    • (1995) Fusion Eng des , vol.30 , pp. 85
    • Rebut, P.-H.1
  • 8
    • 0026136127 scopus 로고
    • Influence of test geometry on tensile strength of fibre-reinforced plastics at cryogenic temperatures
    • Tschegg E., Humer K., Weber H.W. Influence of test geometry on tensile strength of fibre-reinforced plastics at cryogenic temperatures. Cryogenics. 31:1991;312.
    • (1991) Cryogenics , vol.31 , pp. 312
    • Tschegg, E.1    Humer, K.2    Weber, H.W.3
  • 9
    • 0025526373 scopus 로고
    • Fatigue life of composites at room and cryogenic temperatures
    • Gu Y.H., Abdelsalam M.K. Fatigue life of composites at room and cryogenic temperatures. Adv Cryog Eng. 36:1990;929.
    • (1990) Adv Cryog Eng , vol.36 , pp. 929
    • Gu, Y.H.1    Abdelsalam, M.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.