메뉴 건너뛰기




Volumn 24, Issue 2, 2000, Pages 137-149

Dynamic behaviour analysis of a heat recovery steam generator during start-up

Author keywords

Analysis; HRSG; Start up; Water level control

Indexed keywords

COMPUTER SIMULATION; CONTROL; GAS TURBINES; PARAMETER ESTIMATION; PLANT STARTUP; WASTE HEAT UTILIZATION; WATER LEVELS;

EID: 0034131729     PISSN: 0363907X     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1099-114X(200002)24:2<137::AID-ER568>3.0.CO;2-0     Document Type: Article
Times cited : (27)

References (11)
  • 4
    • 0027983406 scopus 로고
    • Modelling the transient behavior of combined cycle plants
    • Dechamps, PJ. 1994. Modelling the transient behavior of combined cycle plants. ASME Paper 94-GT-238.
    • (1994) ASME Paper 94-GT-238
    • Dechamps, P.J.1
  • 5
    • 0342813686 scopus 로고
    • U.S.A.
    • ESCOA Corp. 1979. Fin Tube Manual. U.S.A.
    • (1979) Fin Tube Manual
  • 7
    • 0031397294 scopus 로고    scopus 로고
    • The effect of gas turbine coolant modulation on the part load performance of combined cycle plants - Part 1: Gas turbine
    • Kim TS, Ro ST. 1997. The effect of gas turbine coolant modulation on the part load performance of combined cycle plants - Part 1: gas turbine. Proceedings Institute of Mechanical Engineers, Part A 211:443-451.
    • (1997) Proceedings Institute of Mechanical Engineers, Part A , vol.211 , pp. 443-451
    • Kim, T.S.1    Ro, S.T.2
  • 9
    • 84925935506 scopus 로고
    • Combined cycle power plant start-up effects and constraints of the HRSG
    • Pasha A. 1992. Combined cycle power plant start-up effects and constraints of the HRSG. ASME Paper 92-GT-376.
    • (1992) ASME Paper 92-GT-376
    • Pasha, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.